IEC 60825-2-2005 Safety of laser products - Part 2 Safety of optical fibre communication systems (OFCS)《激光产品的安全.第2部分 光纤通信系统的安全(OFCS)》.pdf
《IEC 60825-2-2005 Safety of laser products - Part 2 Safety of optical fibre communication systems (OFCS)《激光产品的安全.第2部分 光纤通信系统的安全(OFCS)》.pdf》由会员分享,可在线阅读,更多相关《IEC 60825-2-2005 Safety of laser products - Part 2 Safety of optical fibre communication systems (OFCS)《激光产品的安全.第2部分 光纤通信系统的安全(OFCS)》.pdf(132页珍藏版)》请在麦多课文档分享上搜索。
1、 NORME INTERNATIONALE CEIIECINTERNATIONAL STANDARD 60825-22004AMENDEMENT 1AMENDMENT 12006-11Amendement 1 Scurit des appareils laser Partie 2: Scurit des systmes de tlcommunication par fibres optiques (STFO) Amendment 1 Safety of laser products Part 2: Safety of optical fibre communication systems (O
2、FCS) Pour prix, voir catalogue en vigueur For price, see current catalogue IEC 2006 Droits de reproduction rservs Copyright - all rights reserved International Electrotechnical Commission, 3, rue de Varemb, PO Box 131, CH-1211 Geneva 20, SwitzerlandTelephone: +41 22 919 02 11 Telefax: +41 22 919 03
3、00 E-mail: inmailiec.ch Web: www.iec.ch Commission Electrotechnique InternationaleInternational Electrotechnical Commission K CODE PRIX PRICE CODE Copyright International Electrotechnical Commission Provided by IHS under license with IECNot for ResaleNo reproduction or networking permitted without l
4、icense from IHS-,-,- 2 60825-2 Amend. 1 CEI:2006 AVANT-PROPOS Cet amendement a t tabli par le comit dtudes 76 de la CEI: Scurit des rayonnements optiques et matriels laser. Le texte de cet amendement est issu des documents suivants: FDIS Rapport de vote76/346/FDIS 76/353/RVD Le rapport de vote indiq
5、u dans le tableau ci-dessus donnent toute information sur le vote ayant abouti lapprobation de cet amendement. Le comit a dcid que le contenu de cet amendement et de la publication de base ne sera pas modifi avant la date de maintenance indique sur le site web de la CEI sous “http:/webstore.iec.ch“
6、dans les donnes relatives la publication recherche. A cette date, la publication sera reconduite, supprime, remplace par une dition rvise, ou amende. _ Page 20 4.4 Connecteurs de cbles Remplacer le texte existant des Paragraphes 4.4.1, 4.4.2 et 4.4.3 par ce qui suit. 4.4.1 Zones accs non limit Dans
7、les zones accs non limit, si le niveau du rayonnement accessible dpasse le niveau de risque 2 dans le domaine des longueurs donde de 400 nm 700 nm, ou le niveau de risque 1 pour tous les autres domaines de longueurs donde, des moyens appropris doivent alors limiter laccs au rayonnement provenant du
8、connecteur. NOTE Dans une zone accs non limit, les niveaux de risque autoriss les plus levs sont de niveau de risque 2M, pour le domaine des longueurs donde de 400 nm 700 nm, et le niveau de risque 1M, pour tous les autres domaines de longueurs donde (voir 4.9.1). Copyright International Electrotech
9、nical Commission Provided by IHS under license with IECNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-60825-2 Amend. 1 IEC:2006 3 FOREWORD This amendment has been prepared by IEC technical committee 76: Optical radiation safety and laser equipment. The text of thi
10、s amendment is based on the following documents: FDIS Report on voting 76/346/FDIS 76/353/RVD Full information on the voting for the approval of this amendment can be found in the report on voting indicated in the above table. The committee has decided that the contents of this amendment and the bas
11、e publication will remain unchanged until the maintenance result date indicated on the IEC web site under “http:/webstore.iec.ch“ in the data related to the specific publication. At this date, the publication will be reconfirmed, withdrawn, replaced by a revised edition, or amended. _ Page 21 4.4 Ca
12、ble connectors Replace the existing text of Subclauses 4.4.1, 4.4.2 and 4.4.3 as follows. 4.4.1 Unrestricted locations In unrestricted locations, if the accessible radiation level exceeds: hazard level 2 within the wavelength range 400 nm to 700 nm, or hazard level 1 in all other cases, then suitabl
13、e means shall limit access to the radiation from the connector. NOTE In an unrestricted location the highest hazard levels permitted are hazard level 2M for the wavelength range 400 nm to 700 nm and hazard level 1M in all other cases (see 4.9.1) Copyright International Electrotechnical Commission Pr
14、ovided by IHS under license with IECNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- 4 60825-2 Amend. 1 CEI:2006 4.4.2 Zones accs limit Dans les zones accs limit, si le niveau du rayonnement accessible dpasse le niveau de risque 2M dans le domaine des longueurs don
15、de de 400 nm 700 nm, ou le niveau de risque 1M pour tous les autres domaines de longueurs donde, des moyens appropris doivent alors limiter laccs au rayonnement provenant du connecteur. NOTE Dans une zone accs limit, le plus haut niveau de risque autoris est le niveau de risque 1M, 2M ou 3R, le plus
16、 lev tant retenu (voir 4.9.2). 4.4.3 Zones accs contrl Dans les zones accs contrl, si le niveau du rayonnement accessible dpasse le niveau de risque 2M dans le domaine des longueurs donde de 400 nm 700 nm, ou le niveau de risque 1M pour tous les autres domaines de longueurs donde, des moyens appropr
17、is doivent alors limiter laccs au rayonnement provenant du connecteur. NOTE Dans une zone contrle, le plus haut niveau de risque autoris est le niveau de risque 3B (voir 4.9.3). Page 24 4.6 Etiquetage ou marquage Remplacer le texte existant du Paragraphe 4.6 par ce qui suit: 4.6.1 Exigences gnrales
18、Lorsque cela est exig par le prsent paragraphe, chaque connecteur optique, bote pissures ou toute autre pice mettant un rayonnement une fois ouvert, doit tre marqu (par exemple, avec une tiquette, un manchon, un repre, une bande, etc.), si le niveau de risque dans la zone est suprieur au niveau de r
19、isque 1. Les informations doivent comporter les informations donnes aux Tableaux 1, 2, ou 3, en fonction de leur applicabilit. Dans le cas o le rayonnement accessible aux points de dconnexion est de niveau de risque 1, ou de niveau de risque 1M, il est permis de fournir les informations ci-dessus so
20、us forme dinformations pour lutilisateur au lieu dun marquage sur le produit. Les marquages doivent tre de couleur noire sur fond jaune. Il est permis que les tiquettes reproduites dans la documentation fournie par le fabricant ou par lorganisme dexploitation utilisent le noir sur fond blanc. La rdu
21、ction de la taille des inscriptions est acceptable, condition que le rsultat soit lisible. Pour les sous-ensembles contenant des lasers ou des amplificateurs optiques, il est de la responsabilit du fabricant du sous-ensemble de fournir cet tiquetage; tout autre tiquetage est de la responsabilit de l
22、organisme dexploitation. A lexception de ce qui est permis ci-aprs, chaque connecteur optique, bote pissures ou toute autre pice qui, une fois ouverte, est destine permettre laccs un rayonnement optique, doit tre marqu (par exemple, avec une tiquette, un manchon, un repre, une bande, etc.), conformm
23、ent aux Tableaux 1, 2 ou 3, en fonction de leur applicabilit. Copyright International Electrotechnical Commission Provided by IHS under license with IECNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-60825-2 Amend. 1 IEC:2006 5 4.4.2 Restricted locations In restric
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEC6082522005SAFETYOFLASERPRODUCTSPART2SAFETYOFOPTICALFIBRECOMMUNICATIONSYSTEMSOFCS 激光 产品 安全 部分 光纤通信

链接地址:http://www.mydoc123.com/p-1235387.html