1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULJULY 22, 20141UL 2872Outline of Investigation for Heat Detecting Circuit InterruptersIssue Number: 1July 22, 2014Summary of TopicsThis first issue of the Outline of Investigation for Heat Detecti
2、ng CircuitInterrupters, UL 2872, covers heat detecting circuit-interrupters (HDCI)intended for use in dehumidifiers, room air conditioners and otherrefrigeration equipment.ULs Outlines of Investigation are copyrighted by UL. Neither a printed norelectronic copy of an Outline of Investigation should
3、be altered in any way. All ofULs Outlines of Investigation and all copyrights, ownerships, and rights regardingthose Outlines of Investigation shall remain the sole and exclusive property of UL.COPYRIGHT 2014 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTI
4、ON ORDISTRIBUTION WITHOUT PERMISSION FROM ULJULY 22, 2014UL 28722No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Glossary 43 Components 54 Units of Measurement .55 Undated References 5CONSTRU
5、CTION6 General 57 Temperature Sensor Assembly .68 Operating Mechanism .7PERFORMANCE9 General 710 Temperature Calibration-Verification Test .711 Drop Test .812 Humidity Conditioning 813 Leakage Current Measurement 914 Environmental Test Sequence 915 Open Lead Test .916 Overvoltage, Overload and Endur
6、ance Tests 917 Resistance to Environmental Noise Test .1018 Supplemental Voltage Surge Immunity Test 10RATINGS19 General 10MARKINGS20 General .10APPENDIX AStandards for ComponentsA1JULY 22, 2014 UL 2872 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSIO
7、N FROM ULINTRODUCTION1 Scope1.1 These requirements cover heat detecting circuit-interrupters (HDCI) intended for use in dehumidifiers,room air conditioners and other refrigeration equipment. They incorporate the functionality of a leakagecurrent detector interrupter, and are intended to interrupt po
8、wer to the protected device when any of thefollowing conditions occur:a) An overheating condition occurs where the HDCI temperature sensor is mounted in the endproduct, orb) When leakage currents flowing from the conductors of the end products power supply cordexceed a predetermined level, orc) An o
9、pen circuit occurs in one of the temperature sensor leads of the HDCI temperaturesensor.1.2 These devices have a maximum rating of 40 A, and are intended for use on circuits rated 250 Vacmaximum.1.3 These requirements are intended to be used with the requirements of the Standard for Arc-FaultCircuit
10、-Interrupters, UL 1699 as these requirements modify and supplement the requirements of thatStandard.1.4 An HDCI that is also intended to perform other functions, such as overcurrent protection, ground-faultcircuit-interruption, surge suppression, any other similar functions, or any combination there
11、of, shallcomply additionally with the requirements of the applicable Standard(s) that cover devices that providethose functions.2 Glossary2.1 For the purposes of this Outline of Investigation, the following definitions apply. Additional definitionsare in the glossary of the Standard for Arc-Fault Ci
12、rcuit-Interrupters, UL 1699, including the glossary ofSupplement SB.2.2 HEAT DETECTING CIRCUIT-INTERRUPTER (HDCI) A cord mounted device that incorporatesthe functionality of a leakage current detector interrupter (LCDI), and interrupts the circuit to theprotected refrigeration device when any of the
13、 following conditions occur:a) An overheating condition occurs where the HDCI temperature sensor is mounted in the endproduct, orb) When leakage currents flowing from the conductors of the power supply cord of theprotected device exceed a predetermined level, orc) An open circuit occurs in one of th
14、e temperature sensor leads to the HDCI temperaturesensor.2.3 TEMPERATURE SENSOR ASSEMBLY An assembly consisting of a temperature sensingcomponent, wiring, a securement means and other components necessary to sense the temperature ofthe compressor of a protected product and cause the HDCI to interrup
15、t the circuit.JULY 22, 2014UL 28724UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL3 Components3.1 Except as indicated in 3.2, a component of a product covered by this Outline of Investigation shallcomply with the requirements for that compone
16、nt.3.2 A component need not comply with a specific requirement that:a) Involves a feature or characteristic not needed in the application of the component in theproduct covered by this Outline of Investigation, orb) Is superseded by a requirement in this Outline of Investigation.3.3 A component shal
17、l be used in accordance with its rating established for the intended conditions ofuse.3.4 Specific components are recognized as being incomplete in construction features or restricted inperformance capabilities. Such components are intended for use only under limited conditions, such ascertain tempe
18、ratures not exceeding specified limits, and shall be used only under those specific conditionsfor which they have been recognized.4 Units of Measurement4.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.5 Undated References5.1 A
19、ny undated reference to a code or standard appearing in the requirements of this Outline ofInvestigation shall be interpreted as referring to the latest edition of that code or standard.CONSTRUCTION6 General6.1 An HDCI shall comply with the applicable construction requirements in Sections 6 15, 26 2
20、7, 31 33 and SB3 SB5 of the Standard for Arc-Fault Circuit-Interrupters, UL 1699, as modified orsupplemented by the construction requirements of this Outline.JULY 22, 2014 UL 2872 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL7 Temperature
21、Sensor Assembly7.1 A thermostat used as a temperature sensor shall comply with the Standard for Temperature-Indicating and Regulating Equipment, UL 873. Compliance with UL 60730-1 and the applicable Part 2Standard from the UL 60730 series fulfills these requirements.7.2 A temperature sensing positiv
22、e temperature coefficient (PTC) or negative temperature coefficient(NTC) thermistor used as a temperature sensor shall comply with the Standard for Thermistor-TypeDevices, UL 1434.7.3 A temperature sensor assembly shall be provided with a means for securement to the protecteddevice. Bolts, screws, o
23、r other parts provided for mounting the temperature sensor assembly to theprotected device shall be independent of those used to secure the components of the temperature sensorassembly.7.4 A means provided for factory calibration of a temperature sensor assembly shall be factory-securedto restrict u
24、nintentional shifting after calibration.7.5 A means for calibration of a temperature sensor assembly that is accessible or apparent shall bemodified, guarded, or sealed by a means such as soldering to effectively restrict manipulation by hand oran ordinary tool subsequent to factory calibration.7.6
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT28722014ULOUTLINEOFINVESTIGATIONFORHEATDETECTINGCIRCUITINTERRUPTERSISSUE1 探测 电路 断路器 UL 调查 大纲

链接地址:http://www.mydoc123.com/p-1069361.html