1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULAUGUST 14, 20151UL 2562Outline of Investigation for Pendant CableIssue Number: 2August 14, 2015Summary of TopicsThis new issue of the Outline of Investigation for Pendant Cable is beingpublished
2、to include revisions for:The addition of bare copper conductor;The addition of PVC insulation without nylon covering;The addition of alternate thickness of the jacket over messenger wire;The addition of stainless steel in messenger wire;The addition of capacitance and relative permittivity for outdo
3、or use;Clarification of the Outdoor Use requirement and addition of theSunRes rating;The addition of the word Pendant Cable to the markings.ULs Outlines of Investigation are copyrighted by UL. Neither a printed norelectronic copy of an Outline of Investigation should be altered in any way. All ofULs
4、 Outlines of Investigation and all copyrights, ownerships, and rights regardingthose Outlines of Investigation shall remain the sole and exclusive property of UL.COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMIS
5、SION FROM ULAUGUST 14, 2015UL 25622No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .42 Units of Measurement .43 Components 44 Undated References 4CONSTRUCTION5 Materials and Workmanship 56 Genera
6、l 56.1 Assembly 56.2 Conductors 56.3 Insulation 56.4 Jacket .56.5 Messenger wires .6PERFORMANCE7 General 6MARKINGS8 Product Marking 79 Tag, Reel, or Carton Markings 8AUGUST 14, 2015 UL 2562 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTR
7、ODUCTION1 Scope1.1 This Outline covers the requirements for multiple conductor cables intended for use indoors andoutdoors as vertical drop cable from a crane or hoist down to a pendant pushbutton station, or as a controlcable in a crane and hoist system in accordance with Article 610 of the Nationa
8、l Electrical Code (NEC),ANSI/NFPA 70. The wire is rated 300 or 600 Volts, and 60, 75, 90, or 105C (140, 167, 194, or 221F).2 Units of Measurement2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory orapproximate information.3 Components3.1 Except as indica
9、ted in 3.2, a component (including gaskets and polymeric materials) of a productcovered by this outline of investigation shall comply with the requirements for that component.3.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not requir
10、ed in the application of the component in theproduct covered by this outline of investigation, orb) Is superseded by a requirement in this outline of investigation.3.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.3.4 Specific components are in
11、complete in construction features or restricted in performance capabilities.Such components are intended for use only under limited conditions, such as certain temperatures notexceeding specified limits, and shall be used only under those specific conditions.4 Undated References4.1 Any undated refer
12、ence to a code or standard appearing in the requirements of this outline ofinvestigation shall be interpreted as referring to the latest edition of that code or standard.AUGUST 14, 2015UL 25624UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCO
13、NSTRUCTION5 Materials and Workmanship5.1 Only materials that are acceptable for the particular use shall be employed in a wire. Wires shall bemade and finished with the degree of uniformity and grade of workmanship that are practicable in awell-equipped factory.5.2 Each material used in a wire shall
14、 be compatible with all of the other materials used in the wire.6 General6.1 Assembly6.1.1 These constructions consist of two or more insulated conductors cabled together with optional fillersand/or binder tapes of suitable material to form a round cable. A messenger wire or wires is joined to theca
15、bled conductors by means of a web.6.2 Conductors6.2.1 Conductors shall be 18 10 AWG, stranded, soft-annealed copper with or without a continuouscoating of tin over each strand, in accordance with the Standard for Machine-Tool Wires, and Cables, UL1063.6.3 Insulation6.3.1 The thicknesses and material
16、 requirements for PVC or PVC/nylon insulation shall be the same asfor Type THHW or THHN wire in accordance with the Standard for Thermoplastic-Insulated Wires andCables, UL 83; or Type MTW wire Construction A or Construction B in accordance with the Standard forMachine-Tool Wires and Cables, UL 1063
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT25622015ULOUTLINEFORINVESTIGATIONFORPENDANTCABLEISSUE2PDF

链接地址:http://www.mydoc123.com/p-1069302.html