《UL SUBJECT 2524-2017 UL Outline for Investigation In-building 2-Way Emergency Radio Communication Enhancement Systems (Issue 1).pdf》由会员分享,可在线阅读,更多相关《UL SUBJECT 2524-2017 UL Outline for Investigation In-building 2-Way Emergency Radio Communication Enhancement Systems (Issue 1).pdf(74页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULDecember 21, 20171UL 2524Outline of Investigation for In-building 2-Way Emergency RadioCommunication Enhancement SystemsIssue Number: 1Decmeber 21, 2017Summary of TopicsThis First issue of the Ou
2、tline of Investigation for In-building 2-WayEmergency Radio Communication Enhancement Systems, UL 2524,covers products (e.g. repeater, transmitter, receiver, signal boostercomponents, external filters, and battery charging system components)used for in-building 2-way radio emergency radio communicat
3、ionenhancement systems installed in a location to improve wirelesscommunication at that location.ULs Outlines of Investigation are copyrighted by UL. Neither a printed norelectronic copy of an Outline of Investigation should be altered in any way. All ofULs Outlines of Investigation and all copyrigh
4、ts, ownerships, and rights regardingthose Outlines of Investigation shall remain the sole and exclusive property of UL.COPYRIGHT 2017 UL LLCUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULDECEMBER 21, 2017UL 25242No Text on This PageUL COPYRIG
5、HTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULCONTENTSINTRODUCTION1 Scope .62 General 72.1 Components .72.2 Units of measurement .72.3 Undated references .73 Glossary .74 Reserved .10CONSTRUCTION5 General .106 Enclosures 116.1 General 116.2 Enclosure
6、covers 116.3 Battery compartments 127 Internal Materials 128 Accessibility of Uninsulated Live Parts, Film-Coated Wire, and Moving Parts 139 Mechanical Assembly 1510 Protection Against Corrosion .1611 Branch-Circuit Connection .1611.1 General .1611.2 Permanently connected .1612 Other Field-Wiring Co
7、nnections .1812.1 General .1812.2 Field-wiring compartment 1912.3 Power-limited circuits .1912.4 Field-wiring terminals (general application) 2012.5 Field-wiring terminals (qualified application) 2112.6 Field-wiring leads .2213 Internal Wiring 2313.1 General .2313.2 Splices and connections 2413.3 Co
8、nnectors and receptacles .2414 Protective Devices 2415 Current-Carrying Parts 2516 Spacings 2517 Insulating Material 2718 Printed-Wiring Boards .2819 End-of-Line Devices .2820 Voltage-Dropping Resistors 2921 Coil Windings 2922 Components .2922.1 Switches 2922.2 Lampholders and lamps .2922.3 Operatin
9、g mechanisms 3022.4 Across-the-line components .3023 Batteries .3123.1 Rechargeable storage-type used as standby power source 31DECEMBER 21, 2017 UL 2524 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL23.2 Lithium batteries .3124 Grounding f
10、or Products Containing High-Voltage Circuits 3125 Servicing Protection .3525.1 General .3525.2 Trained service personnel .3525.3 Antenna terminal discharge assembly .35PROTECTION AGAINST INJURY TO PERSONS26 General 3627 Sharp Edges .3728 Stability 37PERFORMANCEGENERAL29 Details .3829.1 Tests and vol
11、tages .3829.2 Maximum rated load 39OPERATION TESTS30 General 3931 Operation 4032 Power Supplies .4032.1 General .4032.2 Primary power source .4032.3 Secondary power source(s) 4133 Monitoring for Integrity .4134 Charging Current Test .4334.1 General .4334.2 Discharged battery .4334.3 Charged battery
12、4434.4 Discharged battery - second trial .4435 Electrical Ratings Test 4435.1 General .4435.2 Power input circuits .4435.3 Other external circuits .4536 Jarring Test .4537 Dielectric Voltage-Withstand Test 4638 Leakage Current Test 4739 Component Temperature Test .5140 Abnormal Operation Tests .5440
13、.1 General .5440.2 Operation .5540.3 Field-wiring circuits .5540.4 Electronic components 5540.5 Cooling fans and blowers .5640.6 Transformer burnout 5740.7 Communications circuits 5840.8 Evaluation of reduced spacings on printed-wiring boards 5841 Tests on Special Terminal Assemblies 5941.1 General
14、.5941.2 Mechanical secureness test .59DECEMBER 21, 2017UL 25244UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL41.3 Flexing test 5941.4 Millivolt drop test .5941.5 Temperature test .6042 Strain-Relief Test .6043 Polarity Reversal Test .6044 Po
15、wer-Limited Circuits Test 6044.1 General .6044.2 Maximum voltage 6344.3 Maximum current .6344.4 VAmax(not inherently limited circuits only) .64MANUFACTURING AND PRODUCTION-LINE TESTS45 Dielectric Voltage-Withstand Test .64MARKINGS AND INSTRUCTIONS46 Markings .6546.1 General .6546.2 Permanence of mar
16、king .6947 Installation Wiring Diagram/Instructions 6948 International Languages .72APPENDIX AStandards for ComponentsA1DECEMBER 21, 2017 UL 2524 5UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULINTRODUCTION1 Scope1.1 These requirements cover
17、products (e.g. repeater, transmitter, receiver, signal booster components,external filters, and battery charging system components) used for in-building 2-way radio emergencyradio communication enhancement systems installed in a location to improve wireless communication atthat location.1.2 These re
18、quirements cover products to be employed in accordance with the following Model Buildingand Installation Codes:a) Standard for the Installation, Maintenance, and Use of Emergency Services CommunicationsSystems, NFPA 1221;b) National Electrical Code, NFPA 70;c) National Fire Alarm Code, NFPA 72;d) Fi
19、re Code, NFPA 1;e) Life Safety Code, NFPA 101;f) International Fire Code1.3 The products covered by this standard are intended to be used in combination with other productsand devices to form an in-building 2-way radio emergency radio communication enhancement system. Aninstallation document(s) prov
20、ided with the product describes the various products needed to form anin-building 2-way radio emergency radio communication enhancement system and their intended use andinstallation.1.4 These requirements address the safety and operational requirements prior to installation.1.5 These requirements do
21、 not include determination of compliance with regulations of the FederalCommunications Commission (FCC). Should products covered by these requirements be required tocomply with FCC regulations, a report of verification from the manufacturer is required as evidence ofsuch compliance.DECEMBER 21, 2017
22、UL 25246UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL2 General2.1 Components2.1.1 Except as indicated in 2.1.2, a component of a product covered by this standard shall comply withthe requirements for that component. See Appendix A for a lis
23、t of standards covering components usedin the products covered by this standard.2.1.2 A component is not required to comply with a specific requirement that:a) Involves a feature or characteristic not required in the application of the component in theproduct covered by this standard, orb) Is supers
24、eded by a requirement in this standard.2.1.3 A component shall be used in accordance with its rating established for the intended conditions ofuse.2.1.4 Specific components are incomplete in construction features or restricted in performancecapabilities. Such components are intended for use only und
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ULSUBJECT25242017ULOUTLINEFORINVESTIGATIONINBUILDING2WAYEMERGENCYRADIOCOMMUNICATIONENHANCEMENTSYSTEMSISSUE1PDF

链接地址:http://www.mydoc123.com/p-1069299.html