UL 62275 CRD-2012 UL Standard for Safety for Cable Management Systems - Cable Ties For Electrical Installations - Section Paragraph Reference 3 7 8 9 10 11 Subject Inclusion of Ty.pdf
《UL 62275 CRD-2012 UL Standard for Safety for Cable Management Systems - Cable Ties For Electrical Installations - Section Paragraph Reference 3 7 8 9 10 11 Subject Inclusion of Ty.pdf》由会员分享,可在线阅读,更多相关《UL 62275 CRD-2012 UL Standard for Safety for Cable Management Systems - Cable Ties For Electrical Installations - Section Paragraph Reference 3 7 8 9 10 11 Subject Inclusion of Ty.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): ZODZ, ZODZ2, ZODZ7, ZODZ8Standard Number: UL 62275Edition Date: February 26, 2010Edition Number: 1Section / Paragraph Reference: 3, 7, 8, 9, 10, 11Subject: I
3、nclusion of Type 11 fixing devices and clarification of moisturestabilization requirements.DECISION:UL 62275 is revised as followsAdd the following to 3DV3DV.3 Low hygroscopicity polymerpolymeric material having the characteristic that does not enable attraction or holding of significantamounts of w
4、ater from the surrounding environment. For the purposes of this standard, materials knownto have an equilibrium moisture content of 1.0% or less at 50% RH and 23C are considered to be of lowhygroscopicity.Add the following to 5.2DVReplace Table 1 with Table DV1 followed by a note as follows:Table DV
5、1 - Stabilization time for samplesReference thickness (RT) of the device Stabilization time daysmmRT 1,2 7 11,2RT1,4 210-71,4RT 350-7All thicknesses of materials known to be of low hygroscopicity 2 8 hoursNOTE: Examples of materials known to be of low hygroscopicity include polypropylene, acetal, et
6、hylenetetraflouroethylene, Ethylene chlorotrifluoroethylene, Polyamide 12, and Polyetheretherkeytone.Revise 7.1DV.2 as follows7.1DV.2 The following markings shall be provided on labels, packaging, or installation instructions shippedwith the product:UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER
7、 REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFixing devices Cable ties onlyMax operating temp for application according to Table 3 Max operating temp for application according to Table 3Min operating temp for application according to Table 4aMin operating temp for application according to
8、Table 4Type designation Min installation temp if lower than 0CMechanical strength as declared by the manufacturer Minimum and maximum bundle diameterLoop tensile strength according to Table 2Type designationa) Separately supplied Type 11 fixing devices need not be marked with the minimum operatingte
9、mperature. This marking is optional for such productsRevise 7.6DV as follows7.6DV D1 Add the following:A fixing device that complies with the requirement in 9.7.1DV.4, 9.7.2DV.3A, 9.7.3DV.3A, 11.1.5DV.98,and 11.2DV.4, where applicable, is permitted to be marked S or Support.Revise the following in c
10、lause 88DV.1 Flammability requirements for Type 11 cable ties and fixing devices and Type 21 cable ties andfixing devices8DV.2 Relative thermal index ratings for Type 11 cable ties and fixing devices and Type 21 cable ties andfixing devices8DV.3 Material requirements for Type 11 cable ties and fixin
11、g devices and Type 21 cable ties and fixingdevices8DV.4 Material substitution for Type 11 cable ties and fixing devices and Type 21 cable ties and fixingdevicesAdd the following to Clause 99.2DV D2 Add the following:Moisture stabilization according to 5.2 is not applicable for this test9.3DV.1 DE Ad
12、d the following to the second paragraph:Moisture stabilization according to 5.2 after removal from the refrigerator is not applicable.9.4DV.1 DE Add the following new third paragraph:Moisture stabilization according to 5.2 after removal from the refrigerator is not applicable.9.5.2DV.1 D2 Add the fo
13、llowing:Moisture stabilization according to 5.2 prior to heat aging is not applicable for this test.9.5.3DV.1 D2 Add the following:STANDARD NUMBER: UL 62275 -2-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULMoisture stabilization according to
14、 5.2 prior to temperature cycling is not applicable for this test.9.6.2DV D2 Add the following:Moisture stabilization according to 5.2 prior to heat aging is not applicable for this test.9.6.3DV D2 Add the following:Moisture stabilization according to 5.2 prior to temperature cycling is not applicab
15、le for this test.Revise the following in clause 99.7.1DV.3 For Type 2 and Type 21 devices, Tthe samples shall be subjected to a tensile pull until themechanical strength declared by the manufacturer is reached. This load shall be maintained for 60+50seconds.9.7.1DV.4 A fixing device classified Type
16、2S or 21S,that is declared as intended to provide primarysupport for a flexible conduit, flexible tubing, or cable in accordance with the relevant national installationcode shall maintain this load for 5 minutes. See 7.6DV. The manufacturers mechanical strength for suchproducts shall be at least 220
17、 N (23 kg) (50 lbs).9.7.1DV.5 For Type 2, 2S, 21, or 21S devices, Aafter the test, there shall be no sign of disintegration, norshall there be any crack visible to normal or corrected vision.9.7.1DV.6 For Type 11 devices, each sample shall be subjected to a tensile pull. No individual value shallbe
18、less than the declared mechanical strength of the fixing device.9.7.2DV.1 The test shall be conducted on a new set of samples. Samples shall be assembled andmounted to the test fixture as described in 9.7.1. Moisture stabilization according to 5.2 prior to heat agingis not applicable for this test.9
19、.7.2DV.3 For Type 2 and Type 21 devices, Eeach sample shall be subjected to the tensile pull describedin 9.7.1DV.3 until the mechanical strength declared by the manufacturer is reached. This load shall bemaintained for 60+50seconds.9.7.2DV.3A A fixing device classified Type 2S or 21S, intended to pr
20、ovide primary support for a flexibleconduit, flexible tubing, or cable in accordance with the relevant national installation code shall maintainthis load for 5 minutes. See 7.6DV. The manufacturers mechanical strength for such products shall be atleast 220 N (23 kg) (50 lbs).9.7.2DV.4 For Type 2, 2S
21、, 21, or 21S devices, Aafter the test, there shall be no sign of disintegration norshall there be any crack visible to normal or corrected vision.9.7.2DV.5 For Type 11 devices, each sample shall be subjected to a tensile pull. No individual value shallbe less than 50 percent of the declared mechanic
22、al strength of the fixing device.9.7.3DV.1 The test shall be conducted on a new set of samples. Samples shall be assembled andmounted to the test fixture as described in 9.7.1. Moisture stabilization according to 5.2 prior totemperature cycling is not applicable for this test.9.7.3DV.2 The test asse
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL62275CRD2012ULSTANDARDFORSAFETYFORCABLEMANAGEMENTSYSTEMSCABLETIESFORELECTRICALINSTALLATIONSSECTIONPARAGRAPHREFERENCE37891011SUBJECTINCLUSIONOFTYPDF

链接地址:http://www.mydoc123.com/p-1068729.html