UL 60730-2-7 (ND)-2014 National Differences For UL 60730-2-7 Standard for Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Timers and v.pdf
《UL 60730-2-7 (ND)-2014 National Differences For UL 60730-2-7 Standard for Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Timers and v.pdf》由会员分享,可在线阅读,更多相关《UL 60730-2-7 (ND)-2014 National Differences For UL 60730-2-7 Standard for Automatic Electrical Controls for Household and Similar Use Part 2 Particular Requirements for Timers and v.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60730-2-7Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: ParticularRequirements for Timers and Time SwitchesUL COPYRIGHTED MATERIAL NO
2、T AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60730-2-7Standard for Automatic Electrical Controls for Household and Similar Use; Part 2: ParticularRequirements for Timers and Time SwitchesEdition: 2Edition Date: March 21, 2014These revision
3、s are being issued to reflect the established effective date for UL60730-2-7. For further information regarding Summary of Requirements, please visithttps:/ OF OCTOBER 19, 2018, THE FIRST EDITION OF UL 60730-2-7, THE THIRD EDITIONOF UL 244A, AND THE FIFTH EDITION OF UL 917 WILL BE WITHDRAWN AND WILL
4、BE REPLACED BY THIS STANDARD.This document provides a single listing of the National Differences included in the UL adoption ofthe corresponding IEC standard.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, elec
5、tronic, mechanical photocopying, recording, or otherwisewithout prior permission of UL.UL provides this standards document as is without warranty of any kind, either expressed or implied,including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event wi
6、ll UL be liable for any special, incidental, consequential, indirect or similar damages,including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or theinability to use this standards document, even if UL or an authorized UL representative has been advised
7、of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the pricepaid for this standards document, regardless of the form of the claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against a
8、ny loss, expense, liability, damage, claim, or judgment (including reasonableattorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronicStandard on the purchasers computer system.Copyright 2014 Underwriters Laboratories Inc.JULY 24, 2014NATIONAL DIFFEREN
9、CES FOR UL UL 60730-2-72UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standard
10、s, UL uses the notations indicated below to identify national difference type, andthese types are additionally noted in this document. The standard may not use all types of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhich woul
11、d compromise safety for U.S. consumers and users of products.D2 - These are deviations based on safety practices. These are deviations for IEC requirements that maybe acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These ar
12、e deviations based on the component standards and will not be deleted until a particularcomponent standard is harmonized with the IEC component standard.DE - These are deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each n
13、ational difference contains a description of what the national difference entails. Typically one of thefollowing words is used to explain how the text of the national difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause
14、, table,figure, or annex. Addition is not meant to include adding select words to the base IEC text.Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause,table, figure, or annex without any replacement text.Modification / Modify - A modification is an alter
15、ing of the existing base IEC text such as theaddition, replacement or deletion of certain words or the replacement of an entire clause,subclause, table, figure, or annex of the base IEC text.JULY 24, 2014 NATIONAL DIFFERENCES FOR UL UL 60730-2-7 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER RE
16、PRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences1.101DV DE Addition of the following to the part 2:In IEC terminology, safety is defined as an acceptable level of risk. This is consistent with the intention of ULrequirements to reduce the risk of fire, shock or injury to pers
17、ons.2.1.101DV D2 Addition to the Part 2:CURRENT INRUSH FACTOR: CURRENT INRUSH FACTOR denotes the number by which the normal(steady-state) peak current through a load is multiplied to obtain the peak value of theinrush current through the load.Such as for TV, tungsten and PILOT DUTY loads.4.3.2.101DV
18、 D2 Addition to the part 2:A permanently connected TIMER that has been tested for an ampere or horsepower rating,or both, may have a tungsten-filament load rating, even though it has not been tested fora tungsten-filament lamp load rating, provided the tungsten-filament lamp load rating doesnot exce
19、ed one-tenth the value of the ampere rating or the full-load motor-running current,whichever is greater.4.3.2.102DV D2 Addition to the part 2:An in-line cord or plug-in TIME SWITCH that operates on and off a minimum of once in 24 hshall have a tungsten-filament lamp load rating.Table 7.2DV D2 Replac
20、ement of Table 7.2 of the part 2:JULY 24, 2014NATIONAL DIFFERENCES FOR UL UL 60730-2-74UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULTable7.2DVInformationClauseorsubclauseMethodModification: Replacethelinescorrespondingtoitems7,26,27and28byt
21、hefollowing:7Thetypeofloadcontrolledbyeachcircuit7),101),101A)14,17,6.2C26NumberofcyclesofACTUATION(M)foreachMANUALACTION102)6.10X27Numberofautomaticcycles(A)foreachAUTOMATICACTION102)6.11X28Ageingperiod(Y)forType1.Mor2.Maction102)6.16XAdditiontonote7:7HighinductiveorHifintendedforthecontrolofhighin
22、ductiveloadssuchasgas-tube-signtransformers,fluorescentlamploads,andthelike.Additionalnotes:101AUnlessanin-lineorplug-inTIMESWITCHisacceptableforusewithafull-loadoftungsten-filamentlamps,itshallbemarkedtoindicatethemaximumconnectedincandescentlamploadinwatts.Thevalueoflampwattageistobenotlessthantha
23、tequivalenttoone-tenthofthefull-loadrating.102AAswitchistobeoperatedbymeansofitsACTUATINGMEMBEReithermanuallyorbyanacceptablemachineforaminimumof6000cyclesunlessaparticularapplicationrequiresahighernumberofcyclestobedeclared.Switchcyclesforin-linecord,free-standingandINDEPENDENTLYMOUNTEDCONTROLS,see
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL6073027ND2014NATIONALDIFFERENCESFORUL6073027STANDARDFORAUTOMATICELECTRICALCONTROLSFORHOUSEHOLDANDSIMILARUSEPART2PARTICULARREQUIREMENTSFORTIMERSANDVPDF

链接地址:http://www.mydoc123.com/p-1068505.html