UL 1691 CRD-2017 UL Standard for Safety Single Pole Locking-Type Separable Connectors - Section Paragraph Reference Supplement SA Subject Supplement SA Replacement Enclosure (Hous.pdf
《UL 1691 CRD-2017 UL Standard for Safety Single Pole Locking-Type Separable Connectors - Section Paragraph Reference Supplement SA Subject Supplement SA Replacement Enclosure (Hous.pdf》由会员分享,可在线阅读,更多相关《UL 1691 CRD-2017 UL Standard for Safety Single Pole Locking-Type Separable Connectors - Section Paragraph Reference Supplement SA Subject Supplement SA Replacement Enclosure (Hous.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(
2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): RUUSStandard Number: UL 1691Standard Title: Standard for Single Pole Locking-Type Separable ConnectorsEdition Date: February 29, 2012Edition Number: 1Section / Paragraph Reference: Supplement SASubjec
3、t: Supplement SA: Replacement Enclosure (Housing) for use with specificmanufacturers Single Pole Locking Type Separable Attachment Plug and CordConnector :DECISION:Addition of new Supplement SA:SUPPLEMENT SA REPLACEMENT ENCLOSURE FOR USE WITH SPECIFIC MANUFACTURERSSINGLE POLE LOCKING-TYPE SEPARABLE
4、ATTACHMENT PLUG and CABLE CONNECTORINTRODUCTIONSA1 ScopeSA1.1 These requirements cover replacement enclosure (housing) (see SA3.1) intended for use in thespecific manufacturers single pole locking-type separable attachment plug and cable connector.SA2 GeneralSA2.1 In addition to complying with Secti
5、ons SA3 SA8 of these requirements, the replacementenclosure (housing) alone, and in combination with the complete device (attachment plug and cableconnector, respectively), shall comply with the applicable Construction and Performance requirements inthe main body of this Standard.SA3 DefinitionsSA3.
6、1 REPLACEMENT ENCLOSURE (PART) An individual replacement enclosure (housing) identifiedby the manufacturer for use in the same manufacturers complete device (single pole locking-typeseparable attachment plug and cable connector, respectively).Note: The replacement part is packaged as a “kit” contain
7、ing the individual part and installation instructions (See Section SA8 of thisSupplement).CONSTRUCTIONSA4 GeneralUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSA4.1 The replacement enclosure (housing) shall be formed and assembled so that it
8、 can be installed, inaccordance with the installation instructions, into its specified single pole locking-type separableattachment plug and cable connector without risk of fire or electric shock. Risk of fire or electric shock isdetermined by compliance with the construction and performance require
9、ments herein and the applicablerequirements of the main body of this Standard.SA4.2 A replacement enclosure (housing) part shall only be installed using commonly used tools such asa screw driver or a wrench. A replacement enclosure (housing) shall not be permitted that requires theinstaller to remov
10、e or defeat or replace a factory installed securement means such as a rivet or drive pin.PERFORMANCESA5 GeneralSA5.1 If the replacement enclosure (housing) is recommended for use with more than one device, eachrepresentative combination of replacement enclosure (housing) and device shall be evaluate
11、d.SA6 Replacement Part Assembly TestSA6.1 The replacement enclosure (housing) shall be able to be installed in the specified device and shallbe reliably retained in place without causing an increased risk of fire or electric shock. Compliance isdetermined by inspection and the test of SA6.2 shall be
12、 performed.SA6.2 A sample of the replacement enclosure (housing) shall be assembled to its specified device usingthe manufacturers installation instructions. Upon completion of the assembly, the integrity of thecompleted assembly shall be examined and if necessary, subjected to the applicable perfor
13、mance testingnecessary to maintain continued compliance with this Standard.MARKINGSSA7 GeneralSA7.1 The replacement enclosure (housing) shall be provided in the form of a kit, including marking asdetailed in Section SA7 of this Supplement.SA7.2 A required marking shall be molded, die-stamped, paint-
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL1691CRD2017ULSTANDARDFORSAFETYSINGLEPOLELOCKINGTYPESEPARABLECONNECTORSSECTIONPARAGRAPHREFERENCESUPPLEMENTSASUBJECTSUPPLEMENTSAREPLACEMENTENCLOSUREHOUSPDF

链接地址:http://www.mydoc123.com/p-1067625.html