TIA-590-A-1997 Standard for Physical Location and Protection of Below Ground Fiber Optic Cable Plant (ANSI APPROVAL WITHDRAWN JUNE 2003)《地下光缆设施的物理位置和保护的标准》.pdf
《TIA-590-A-1997 Standard for Physical Location and Protection of Below Ground Fiber Optic Cable Plant (ANSI APPROVAL WITHDRAWN JUNE 2003)《地下光缆设施的物理位置和保护的标准》.pdf》由会员分享,可在线阅读,更多相关《TIA-590-A-1997 Standard for Physical Location and Protection of Below Ground Fiber Optic Cable Plant (ANSI APPROVAL WITHDRAWN JUNE 2003)《地下光缆设施的物理位置和保护的标准》.pdf(30页珍藏版)》请在麦多课文档分享上搜索。
1、TIA DOCUMENT Standard for Physical Location and Protection of Below Ground Fiber Optic Cable Plant TIA-590-A ANSI APPROVAL WITHDRAWN JUNE 2003 JANUARY 1997 TELECOMMUNICATIONS INDUSTRY ASSOCIATION NOTICE TIA Engineering Standards and Publications are designed to serve the public interest through elim
2、inating misunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for their particular need. The existence of such Publications shall not in any res
3、pect preclude any member or non-member of TIA from manufacturing or selling products not conforming to such Publications. Neither shall the existence of such Documents preclude their voluntary use by non-TIA members, either domestically or internationally. TIA DOCUMENTS TIA Documents contain informa
4、tion deemed to be of technical value to the industry, and are published at the request of the originating Committee without necessarily following the rigorous public review and resolution of comments which is a procedural part of the development of a American National Standard (ANS). Further details
5、 of the development process are available in the TIA Engineering Manual, located at TIA Documents shall be reviewed on a five year cycle by the formulating Committee and a decision made on whether to reaffirm, revise, withdraw, or proceed to develop an American National Standard on this subject. Sug
6、gestions for revision should be directed to: Standards Engineering Association As-built facility location record - This record contains physical location information and details needed to assist in locating the fiber optic cable. Details should also include the location of abrupt deviations taken fr
7、om the cables normal planned route and placing depth. Such deviations, caused by foreign underground structures or geological obstructions, whether planned in advance or uncovered during the cable installation should be recorded when: - horizontal deviations made from the facilitys route extend beyo
8、nd the tolerance zone specified in the applicable damage prevention law or, where none is specified, by an equivalent 450-mm (1 8-in.) tolerance zone from either side of the facility (see figures 1 and 2). - any vertical deviation that results in a depth less than the design minimum, or a depth exce
9、eding the design minimum by 300 mm (12 in.) or more. The measurements giving the location and extent of such deviations should be noted either when the route is planned, or reported at the time the obstruction is discovered during installation of the facility. Distribution Pipeline - A gas pipeline
10、other than a transmission gas pipeline. EIA - Electronics Industry Association Excavation - Any operation in which earth, rod, or other material in the ground is moved, removed, or otherwise displaced by means of any tools, equipment, or explosives, and includes, but is not limited to, digging, auge
11、ring, drilling, trenching, scraping, plowing, boring, or tunneling. 2 TINElA-590A Excavator - The person, company, or business that does the excavating. Excavation Site - The specific location where excavation work is to be performed. Facility Owner - The utility, firm, agency, or individual that is
12、 responsible for the fiber optic facilitys operation and maintenance. FHWA - Federal Highway Administration IHROW - Interstate Highway Right-Of-Way NESC - National Electrical Safety Code OCSI - One-Call Systems International OneCall Bureau - An organization established by two or more agencies or com
13、panies to provide one telephone number for excavators, utilities, public agencies, and private citizens to call to notify facility owners of their intent to excavate. Calling the one-call bureau is intended to be the means of notifying all participating facility owners to locate and mark their facil
14、ities in the vicinity of the proposed work to prevent facility damage by the excavator. A onecall bureau may serve an entire state. Some states have several one-call bureaus covering specific areas. The One-Call Systems International (OCSI) of the American Public Works Association (APWA) publishes a
15、n annual directory that gives the names, addresses, and telephone numbers of all onecall bureaus. A copy of this directory may be obtained by contacting: American Public Works Association 2345 Grand Blvd. Kansas City, MO 641 08-2625 Tel. - (81 6) 472-61 O0 FAX - (816) 472-1610 Excavators and owners
16、may also obtain further information concerning programs and publications from the APWA headquarters. OSHA - Occupational Safety and Health Administration TIA - Telecommunications Industry Association Tolerance Zone - The zone where excavation is to be performed with hand tools or nondestructive tool
17、s until the facility is exposed or the maximum depth of the intended excavation is reached. Damage prevention laws usually specify the location of this zone. (See figures 1 and 2.) 3 TINEIA-590A Color Red Yellow Transmission Pipeline - A gas pipeline between storage and distribution facilities. A tr
18、ansmission pipeline usually operates at a pressure of 862 kPa (125 psi) or more, or at a hoop stress of 20 percent or more of its specified minimum yield strength regardless of its operating pressure. Facility Electric power lines and conduit Gas, oil, steam, and petroleum lines ULCC - Utility Locat
19、ion and Coordination Council Blue Green Orange White Uniform Color Code - An APWA guide that has been accepted as a national convention for the color-coded temporary marking of subsurface facilities to prevent accidental damage by those excavating nearby. The Uniform Color Code was developed by the
20、Utility Location and Coordination Council (ULCC) and adopted by the APWA to both mark and identify subsurface facilities. This color code is also recommended for permanent above-ground and below-ground markings. The colors assigned and types of facility are specified in table 1. - Water, irrigation,
21、 and slurry lines Sewer and drain lines Communication lines, including fiber optic cable Proposed excavation Table 1 - Uniform color code Fluorescent Pink Temporary survey markings 4 TIAIElA-590A 4 REQUIREMENTS 4.1 Fiber optic cable installation planning The facility owner is responsible for correct
22、 route design and installation of the fiber optic cable. Fiber optic cable plant should be constructed in accordance with plans and specifications prepared under the supervision of a qualified engineer. The proper design of a fiber optic cable below-ground route is important, this being the first st
23、ep in avoiding damage to that cable by future work operations performed in the area. The following guidelines are provided to convey additional advice and information, and to emphasize that fiber optic cable placement should be in accordance with this Standard and recognized industry installation pr
24、ocedures. They should not be taken as all-inclusive and may not be applicable to all installations. - Plans for the location and installation of below-ground fiber optic cable should be made using information obtained from a field survey. - The installation plans should identify the fiber cable faci
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- TIA590A1997STANDARDFORPHYSICALLOCATIONANDPROTECTIONOFBELOWGROUNDFIBEROPTICCABLEPLANTANSIAPPROVALWITHDRAWNJUNE2003

链接地址:http://www.mydoc123.com/p-1060690.html