SANS 60079-6-2009 Explosive atmospheres Part 6 Equipment protection by oil-immersion o 《爆燃性空气 第6部分 采用油浸保护设备 “o”》.pdf
《SANS 60079-6-2009 Explosive atmospheres Part 6 Equipment protection by oil-immersion o 《爆燃性空气 第6部分 采用油浸保护设备 “o”》.pdf》由会员分享,可在线阅读,更多相关《SANS 60079-6-2009 Explosive atmospheres Part 6 Equipment protection by oil-immersion o 《爆燃性空气 第6部分 采用油浸保护设备 “o”》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-22289-5 SANS 60079-6:2009Edition 3IEC 60079-6:2007Edition 3SOUTH AFRICAN NATIONAL STANDARD Explosive atmospheres Part 6: Equipment protect
4、ion by oil immersion “o” This national standard is the identical implementation of IEC 60079-6:2007 and is adopted with the permission of the International Electrotechnical Commission. WARNING Can only be used in conjunction with SANS 60079-0 Published by SABS Standards Division 1 Dr Lategan Road Gr
5、oenkloof Private Bag X191 Pretoria 0001Tel: +27 12 428 7911 Fax: +27 12 344 1568 www.sabs.co.za SABS SANS 60079-6:2009 Edition 3 IEC 60079-6:2007 Edition 3 Table of changes Change No. Date Scope National foreword This South African standard was approved by National Committee SABS TC 65, Explosion pr
6、evention, in accordance with procedures of the SABS Standards Division, in compliance with annex 3 of the WTO/TBT agreement. This SANS document was published in June 2009. This SANS document supersedes SANS 60079-6:1995 (edition 2 as modified by IEC corr. 1:2003 and nat. amdt 1:2000). NORME INTERNAT
7、IONALECEIIECINTERNATIONAL STANDARD 60079-6Troisime ditionThird edition2007-03Atmosphres explosives Partie 6: Protection du matriel par immersion dans lhuile o Explosive atmospheres Part 6: Equipment protection by oil immersion o Pour prix, voir catalogue en vigueur For price, see current catalogue I
8、EC 2007 Droits de reproduction rservs Copyright - all rights reserved Aucune partie de cette publication ne peut tre reproduite ni utilise sous quelque forme que ce soit et par aucun procd, lectronique ou mcanique, y compris la photocopie et les microfilms, sans laccord crit de lditeur. No part of t
9、his publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from the publisher. International Electrotechnical Commission, 3, rue de Varemb, PO Box 131, CH-1211 Geneva 20, SwitzerlandTelephon
10、e: +41 22 919 02 11 Telefax: +41 22 919 03 00 E-mail: inmailiec.ch Web: www.iec.ch CODE PRIX PRICE CODE P Commission Electrotechnique InternationaleInternational Electrotechnical Commission SANS 60079-6:2009This s tandard may only be used and printed by approved subscription and freemailing clients
11、of the SABS .60079-6 IEC:2007 3 CONTENTS FOREWORD.5 1 Scope.9 2 Normative references .9 3 Terms and definitions .11 4 Constructional requirements.13 4.1 General .13 4.2 Protective liquid.13 4.3 Group I equipment.13 4.4 Deterioration of the protective liquid 13 4.5 Guarding of fasteners15 4.6 Protect
12、ive level indication15 4.7 Limiting temperature17 4.8 Immersion depth17 4.9 Capillary or siphon action 17 4.10 Devices for draining of liquid .17 4.11 Sealed enclosures.17 4.12 Non-sealed enclosures17 4.13 External connections .19 5 Verifications and tests 19 5.1 Type tests .19 5.2 Routine tests .19
13、 6 Marking 21 7 Instructions.21 Annex A (informative) Introduction of an alternative risk assessment method encompassing “equipment protection levels“ for Ex equipment .23 Table A.1 Traditional relationship of EPLs to Zones (no additional risk assessment)27 Table A.2 Description of risk of ignition
14、protection provided .29 SANS 60079-6:2009This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .60079-6 IEC:2007 5 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ EXPLOSIVE ATMOSPHERES Part 6: Equipment protection by oil immersion “o“ FOREWORD 1) The In
15、ternational Electrotechnical Commission (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and el
16、ectronic fields. To this end and in addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical commit
17、tees; any IEC National Committee interested in the subject dealt with may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for
18、Standardization (ISO) in accordance with conditions determined by agreement between the two organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee h
19、as representation from all interested IEC National Committees. 3) IEC Publications have the form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accur
20、ate, IEC cannot be held responsible for the way in which they are used or for any misinterpretation by any end user. 4) In order to promote international uniformity, IEC National Committees undertake to apply IEC Publications transparently to the maximum extent possible in their national and regiona
21、l publications. Any divergence between any IEC Publication and the corresponding national or regional publication shall be clearly indicated in the latter. 5) IEC provides no marking procedure to indicate its approval and cannot be rendered responsible for any equipment declared to be in conformity
22、with an IEC Publication. 6) All users should ensure that they have the latest edition of this publication. 7) No liability shall attach to IEC or its directors, employees, servants or agents including individual experts and members of its technical committees and IEC National Committees for any pers
23、onal injury, property damage or other damage of any nature whatsoever, whether direct or indirect, or for costs (including legal fees) and expenses arising out of the publication, use of, or reliance upon, this IEC Publication or any other IEC Publications. 8) Attention is drawn to the Normative ref
24、erences cited in this publication. Use of the referenced publications is indispensable for the correct application of this publication. 9) Attention is drawn to the possibility that some of the elements of this IEC Publication may be the subject of patent rights. IEC shall not be held responsible fo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS6007962009EXPLOSIVEATMOSPHERESPART6EQUIPMENTPROTECTIONBYOILIMMERSIONO 爆燃 空气 部分 采用 保护 设备 PDF

链接地址:http://www.mydoc123.com/p-1031210.html