1、SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirelyvoluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefro
2、m, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions.Copyright 2001 Society of Automotive Engineers, Inc.All rights reserved. Printed in U.S.
3、A.TO PLACE A DOCUMENT ORDER: (724) 776-4970 FAX: (724) 776-0790 SAE WEB ADDRESS: http:/www.sae.org400 Commonwealth Drive, Warrendale, PA 15096-0001AEROSPACE STANDARDAS1303REV.AIssued 1973-05Revised 1996-10Reaffirmed 2001-10Portable Chemical Oxygen1. SCOPE:This SAE Aerospace Standard (AS) applies to
4、a portable chemical oxygen generator assembly intended for the following uses:a. First aid treatment of aircraft occupants after an emergency descent following a decompression or other emergency condition.b. Use by cabin attendants to maintain their mobility after a decompression.2. REFERENCES:2.1 A
5、pplicable Documents:The following publications form a part of this document to the extent specified herein. The latest issue of SAE publications shall apply. The applicable issue of other publications shall be the issue in effect on the date of the purchase order. In the event of conflict between th
6、e text of this document and references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained.2.1.1 SAE Publications: Available from SAE, 400 Commonwealth Drive, Warrendale,
7、 PA 15096-0001.ARP1894 Useful Life Determination for Chemical Oxygen GeneratorsAS8010 Aviators Breathing Oxygen Purity Standard2.1.2 RTCA Documents: Available from Radio Technical Commission for Aeronautics Secretariat, Suite 500, 1425 K Street, N.W., Washington, DC 20005. The latest issue of applic
8、able RTCA documents shall apply.RTCA/DO-160 Environmental Conditions and Test Procedures for Airborne EquipmentCopyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-SAE AS1303 Revision A- 2 -2.1.3 EUROCAE Do
9、cuments: Available from EUROCAE - 11, rue Hamelin - 75783 PARIS CEDEX 16, France.ED-14 Environmental Conditions and Test Procedures for Airborne Electronic/Electrical Equipment and InstrumentsNOTE: EUROCAE ED-14C and RTCA/DO-160C are equivalent documents. It is anticipated this equivalency will be m
10、aintained in future revisions. However, in the event of differences between future versions of these documents, the requirements stated in RTCA/DO-160 shall take precedence.2.1.4 FAA Documents: Available from US Government Printing Office, Superintendent of Documents, Washington, DC 20402-9329.TSO C
11、64a Oxygen Mask Assembly, Continuous Flow, Passenger2.1.5 ASQC Documents: Available from American Society for Quality Control, 230 Wells St., Milwaukee, WI 53203.The ASQC Basic References in Quality Control, Volume 4: How to Perform Skip-Lot and Chain Sampling, by Kenneth S. Stephens2.2 Related Publ
12、ications:2.2.1 NATO Publications: Available from North Atlantic Treaty Organization, Military Agency for Standardization (MAS), 1110 Brussels, Belgium. Also available from Naval Publications and Forms Center, 5801 Tabor Avenue, Philadelphia, PA 19120.STANAG 3688 GGS Characteristics Of Breathable Oxy
13、gen Supplied By Chemical Solid Generators2.3 Definitions:CHEMICAL CORE: An object, composed of sodium chlorate or an analogous alkali metal chlorate or perchlorate, formulated with fuels, catalysts, and other modifiers and additives as required by the particular design, which evolves oxygen by a con
14、trolled chemical decomposition reaction, when actuated. Also sometimes called a chlorate candle.CHEMICAL OXYGEN GENERATOR: A device comprising a chemical core and its surrounding mechanical enclosure, insulating material, actuation means for the chemical core, pressure relief means, and any necessar
15、y filtering means. A means of conveying evolved oxygen to the masks is also frequently included, although that function can also be fulfilled by an external manifold.Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without licens
16、e from IHS-,-SAE AS1303 Revision A- 3 -2.3 (Continued):CHLORATE CANDLE: An alternate term sometimes applied to a chemical core, possibly because the progress of the organized decomposition reaction along the length of the core can be likened to the burning of a candle. This term is also sometimes lo
17、osely applied to the entire chemical oxygen generator.GENERATOR CARTRIDGE: An assembly comprising a chemical core and its surrounding mechanical enclosure, insulating material, initiation means for the chemical core, pressure relief means, and any necessary filtering means, which is designed as a re
18、placeable component, and is intended for insertion into a reusable portable chemical oxygen device, as a means of recharging the device.PORTABLE CHEMICAL OXYGEN DEVICE: A piece of equipment used as a portable supply of oxygen, which is produced by means of a chemical reaction. Generally comprises th
19、e oxygen generator, carrying case, oxygen mask, and all other system components, assembled in an integrated package.SKIP-LOT SAMPLING: A method of selecting samples for inspection by applying the principles of a continuous sampling plan to a continuing series of lots or batches rather than to indivi
20、dual product lots. For processes having a high degree of process capability this approach can be more cost effective than conventional sampling plans. Consult the ASQC reference cited in 2.1.5 for more details regarding construction of this type of sampling plan.STPD: Standard Temperature and Pressu
21、re, Dry. Conditions comprising a temperature of 0 C (32 F) and one atmosphere absolute pressure (101.3 kPa or 760 mm of Hg), dry basis (partial pressure of water vapor equals zero).3. REQUIREMENTS:3.1 Device Characteristics:3.1.1 The portable chemical oxygen device should typically comprise the foll
22、owing components. However, alternate design features which accomplish equivalent performance are acceptable. a. Outer Case to house the remainder of the components and to protect the user from contact with the hot inner components during operation. b. Adjustable Carrying Strap, sufficiently large to
23、 stretch across an aircraft seat back. c. At least one oxygen mask or other oxygen dispensing device and flexible tubing. d. One or more replaceable oxygen generator cartridges, which generate the oxygen supply, unless the entire oxygen generator is intended as a single use device.e. Relief valves o
24、r other relief means on each generator cartridge. Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-SAE AS1303 Revision A- 4 -3.1.1 (Continued):f. Actuating mechanisms to be part of each generator assemb
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS1303A1996PORTABLECHEMICALOXYGEN 便携式 化学 氧气 PDF

链接地址:http://www.mydoc123.com/p-1023465.html