NEMA LE 5-2001 Procedure for Determining Luminaire Efficacy Ratings for Fluorescent Luminaires (Scope for Additional Partially Replaced Information)《额外部分替换的信息的荧光灯范围的灯具功效评定等级测定程序[ N.pdf
《NEMA LE 5-2001 Procedure for Determining Luminaire Efficacy Ratings for Fluorescent Luminaires (Scope for Additional Partially Replaced Information)《额外部分替换的信息的荧光灯范围的灯具功效评定等级测定程序[ N.pdf》由会员分享,可在线阅读,更多相关《NEMA LE 5-2001 Procedure for Determining Luminaire Efficacy Ratings for Fluorescent Luminaires (Scope for Additional Partially Replaced Information)《额外部分替换的信息的荧光灯范围的灯具功效评定等级测定程序[ N.pdf(33页珍藏版)》请在麦多课文档分享上搜索。
1、NEMA Standards PublicationNational Electrical Manufacturers AssociationNEMA LE 5-2001Procedure for Determining Luminaire Efficacy Ratings for Fluorescent LuminairesNEMA Standards Publication LE 5 - 2001 Procedure for Determining Luminaire Efficacy Ratings for Fluorescent Luminaires Published by Nati
2、onal Electrical Manufacturers Association 1300 North 17 th Street, Suite 1847 Rosslyn, VA 22209 Copyright 2001 by the National Electrical Manufacturers Association. All rights including translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the
3、Protection of Literary and Artistic Works, and the International and Pan American Copyright Conventions. LE 5- 2001 Page i Contents Page Foreword . iii Purpose iv Section 1 GENERAL 1 1.1 Scope 1 1.2 Referenced Publications 1 1.3 Definitions . 2 Section 2 S ELECTION OF COMPONENTS 3 2.1 Test Specimen
4、Lighting Fixture . 3 2.2 Test Specimen(s) Fluorescent Ballast(s) 3 2.3 Test Specimen(s) Fluorescent Lamps 3 Section 3 TESTING FACIL ITIES AND EQUIPMENT 5 3.1 Facilities 5 3.2 General Criteria 5 Section 4 PROCEDURE . 7 4.1 Luminaire Efficacy Rating Fluorescent Luminaires . 7 4.2 Luminaire Type and Cl
5、assification . 7 4.3 Exceptions 7 4.4 Luminaire Efficacy Rating Fluorescent Luminaires Reg ulatory Requirements . 8 Section 5 CALCULATIONS 9 5.1 Luminaire Efficacy Rating Fluorescent Luminaires . 9 5.2 Calculation of ballast factor 10 Section 6 LIGHTING ENERGY COST . 11 6 .1 Comparative Yearly Energ
6、y Cost of Light 11 6.2 Calculation 11 Section 7 RE COMMENDED REPORTING CATEGORIES AND FORMAT . 13 7.1 Category Description 13 7.2 Recommended Reporting Format 13 Appendix A THE RATIONALE AND RECOMMENDED REGULATIONS FOR FLUORESCENT LUMINAIRES 15 A. 1 Luminaire Characteristics . 15 A.2 Fluorescent Mar
7、ket Percentage by Types Shipped 16 A.3 Luminaire Types and Classifications 17 A.4 Heat Transfer Luminaires . 17 A.5 Recommended Regulations Fluorescent Luminaires Only 17 A.6 Photometric Tests . 18 LE 5- 2001 Page ii Table S 5 - 1 Typical Rated Fluorescent Lamp Lumens . 10 7 - 2 Reporting Format 13
8、A - 1 Minimum LER Lensed Recessed Fluorescent Luminaires with Spacing Criterion 1.1 18 A - 2 Minimum LER Louvered Recessed Fluorescent Luminaires with VCP 80 and Spacing Criterion 1.1 19 A - 3 Minimum LER Plastic Wraparound Luminaires 20 A - 4 Minimum LER Bare Lamp Strip Luminaires 20 A - 5 Minimum
9、LER Bare Lamp Industrial Luminaires . 20 A - 6 Typical Rated Average Ballast Factors Nominal 2 - , 4 - , and 8 - foot Fluorescent . 21 A - 7 Typical Rated Input Watts Fluorescent, Recessed Lensed . 22 A - 8 Typical Rated Input Watts Fluorescent, Recessed Louvered 23 A - 9 Typical Rated Input Watts F
10、luorescent Plastic Wraparound 24 A - 10 Typical Rated Input Watts Fluorescent Strip Ligh ts 25 A - 11 Typical Rated Input Watts Fluorescent Industrials 26 LE 5- 2001 Page iii FOREWORD This standards publication was developed to assist the federal government, state governments, electrical utility com
11、panies, and manufacturers of lighting fixtures in performing a standardized test method for determining the luminaire efficacy rating of fluorescent lighting fixtures incorporating various shielding media and various types of applicable lamps and ballasts. This standards publication was prompted by
12、the need of the l ighting fixture manufacturing industry to have a uniform method of determining energy efficiency of their products using various components. It is not the intent of this standards publication to inhibit luminaire design or to impose arbitrary tolerances o n any luminaire manufactur
13、er. Even though the recommendations for regulations in Appendix A take into consideration in part lighting quality through incorporation of visual comfort probability, the International Association of Lighting Designers and the I lluminating Engineering Society of North America desire to include in
14、the future an additional numerical value for lighting quality to accompany the luminaire efficacy rating value. This numerical expression for lighting quality has not yet been fully dev eloped. The Luminaire Section accomplished the preparation of this standards publication in close cooperation with
15、 the Lamp and Ballast Sections of the NEMA Lighting Systems Division. Input from users and other interested p arties has been sought and evaluated. Inquiries, comments, and proposed or recommended revisions should be submitted to the Luminaire Section of NEMA by contacting: Vice President, Engineeri
16、ng Department National Electrical Manufacturer s Association 1300 North 17 th Street, Suite 1847 Rosslyn, VA 22209 The standards or guidelines presented in a NEMA standards publication are considered technically sound at the time they are approved for publication. They are not a substitute for a pro
17、duct sellers or users own judgment with respect to the particular product referenced in the standard or guideline, and NEMA does not undertake to guarantee the performance of any individual manufacturers products by virtue of this standard or guide. T hus, NEMA expressly disclaims any responsibility
18、 for damages arising from the use, application, or reliance by others on the information contained in these standards or guidelines. This standards publication was developed by the Luminaire Section. Sectio n approval of the standard does not necessarily imply that all section members voted for its
19、approval or participated in its development. At the time it was approved, the group/section was composed of the following members: American Electric Lighting Coop er Lighting Group EGS Electrical Group GE Lighting Systems Genlyte Thomas Group Hubbell, Incorporated Holophane Corporation Indy Lighting
20、 Incorporated Juno Lighting, Incorporated Lighting Corporation of America Lithonia Lighting Group Red Dot Division, L.E . Mason Simkar Corporation Steel Craft Industries The Jones Metal Products Company LE 5- 2001 Page iv PURPOSE The purpose of this standards publication is to: a. Provide government
21、al agencies with a practical and uniform method for calculating a metric for regulating th e “energy efficiency“ of fluorescent luminaires. b. Provide electrical utility companies with a method to establish minimum luminaire efficacy ratings for use with energy savings rebate programs. c. Provide a
22、LER methodology for fluorescent luminaires that is applicable to all lamp/ballast systems, thus providing a tool for promoting energy efficient luminaires to the lighting engineering and design community. d. Create a workable and realistic number of fluorescent luminaire types for regulating “ene rg
23、y efficiency.“ e. Organize the types of luminaires into categories that will reasonably represent the design function, physical and dimensional attributes, and the photometric characteristics of the various types of high volume luminaires. f. Preserv e for the lighting fixture manufacturers and the
24、lighting industry the right to use laboratory facilities, testing methods, and completed test data that currently exist and are in accordance with approved industry standards. g. Establish a luminaire effi cacy rating (LER) based on rated lumens per watt, in lieu of a standard based solely on either
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NEMALE52001PROCEDUREFORDETERMININGLUMINAIREEFFICACYRATINGSFORFLUORESCENTLUMINAIRESSCOPEFORADDITIONALPARTIALLYREPLACEDINFORMATION

链接地址:http://www.mydoc123.com/p-994281.html