NAVY UFGS-33 71 02 00 20-2008 UNDERGROUND ELECTRICAL DISTRIBUTION《地下配电》.pdf
《NAVY UFGS-33 71 02 00 20-2008 UNDERGROUND ELECTRICAL DISTRIBUTION《地下配电》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-33 71 02 00 20-2008 UNDERGROUND ELECTRICAL DISTRIBUTION《地下配电》.pdf(50页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-33 71 02.00 20 (August 2008)-Preparing Activity: NAVFAC SupersedingUFGS 33 71 02.00 20 (February 2007)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2008*SECTION TABLE OF CONTENTSDIVISION 33 - UTILITIESSECTION 33 71 02.00
2、20UNDERGROUND ELECTRICAL DISTRIBUTION08/08PART 1 GENERAL1.1 REFERENCES1.2 DEFINITIONS1.3 SUBMITTALS1.4 QUALITY ASSURANCE1.4.1 Precast Underground Structures1.4.2 Certificate of Competency for Cable Splicer/Terminator1.4.3 Cable Installer Qualifications1.4.4 Regulatory Requirements1.4.5 Standard Prod
3、ucts1.4.5.1 Alternative Qualifications1.4.5.2 Material and Equipment Manufacturing DatePART 2 PRODUCTS2.1 CONDUIT, DUCTS, AND FITTINGS2.1.1 Rigid Metal Conduit2.1.1.1 Rigid Metallic Conduit, PVC Coated2.1.2 Intermediate Metal Conduit2.1.2.1 Intermediate Metal Conduit, PVC Coated2.1.3 Plastic Conduit
4、 for Direct Burial2.1.4 Plastic Duct for Concrete Encasement2.1.5 Bituminized Fiber Duct2.1.6 Innerduct2.1.7 Conduit Sealing Compound2.1.8 Fittings2.1.8.1 Metal Fittings2.1.8.2 PVC Conduit Fittings2.1.8.3 PVC Duct Fittings2.1.8.4 Outlet Boxes for Steel Conduit2.2 LOW VOLTAGE INSULATED CONDUCTORS AND
5、 CABLES2.2.1 Conductor Types2.2.2 Conductor Material2.2.3 Jackets2.2.4 Direct BuriedSECTION 33 71 02.00 20 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.2.5 In Duct2.2.6 Cable Marking2.3 LOW VOLTAGE WIRE CONNECTORS AND TERMINALS2.4 LOW VOLT
6、AGE SPLICES2.4.1 Heat Shrinkable Splice2.4.2 Cold Shrink Rubber Splice2.5 MEDIUM VOLTAGE CABLE2.5.1 Cable Configuration2.5.2 Conductor Material2.5.3 Insulation2.5.4 Shielding2.5.5 Neutrals2.5.6 Jackets2.6 MEDIUM VOLTAGE CABLE TERMINATIONS2.6.1 Cold-Shrink Type2.6.2 Heat Shrinkable Type2.6.3 Separabl
7、e Insulated Connector Type2.7 MEDIUM VOLTAGE CABLE JOINTS2.7.1 Heat-Shrinkable Joint2.7.2 Cold-Shrink Rubber-Type Joint2.8 TELECOMMUNICATIONS CABLING2.9 LIVE END CAPS2.10 TAPE2.10.1 Insulating Tape2.10.2 Buried Warning and Identification Tape2.10.3 Fireproofing Tape2.11 PULL ROPE2.12 GROUNDING AND B
8、ONDING2.12.1 Driven Ground Rods2.12.2 Grounding Conductors2.13 CAST-IN-PLACE CONCRETE2.14 UNDERGROUND STRUCTURES2.14.1 Cast-In-Place Concrete Structures2.14.2 Precast Concrete Structures, Risers and Tops2.14.2.1 General2.14.2.2 Design for Precast Structures2.14.2.3 Construction2.14.2.4 Joints2.14.3
9、Manhole Frames and Covers2.14.4 Handhole Frames and Covers2.14.5 Frames and Covers for Airfield Facilities2.14.6 Ductile Iron Frames and Covers for Airfield Facilities2.14.7 Brick for Manhole Collar2.14.8 Composite/Fiberglass Handholes and Covers2.15 CABLE SUPPORTS (RACKS, ARMS, AND INSULATORS)2.15.
10、1 Cable Racks2.15.2 Rack Arms2.15.3 Insulators2.16 CABLE TAGS IN MANHOLES2.16.1 Polyethylene Cable Tags2.17 CABLE TERMINATING CABINETS2.18 PROTECTIVE DEVICES AND COORDINATION2.19 SOURCE QUALITY CONTROL2.19.1 Arc-Proofing Test for Cable Fireproofing Tape2.19.2 Medium Voltage Cable Qualification and P
11、roduction TestsPART 3 EXECUTION3.1 INSTALLATIONSECTION 33 71 02.00 20 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.2 CABLE INSPECTION3.3 CABLE INSTALLATION PLAN AND PROCEDURE3.4 UNDERGROUND FEEDERS SUPPLYING BUILDINGS3.5 UNDERGROUND STRUCT
12、URE CONSTRUCTION3.5.1 Cast-In-Place Concrete Structures3.5.2 Precast Concrete Construction3.5.3 Pulling-In Irons3.5.4 Cable Racks, Arms and Insulators3.5.5 Field Painting3.6 DIRECT BURIAL CABLE SYSTEM3.6.1 Trenching3.6.2 Cable Installation.3.6.3 Splicing3.6.4 Bends3.6.5 Horizontal Slack3.6.6 Identif
13、ication Slabs Markers3.7 UNDERGROUND CONDUIT AND DUCT SYSTEMS3.7.1 Requirements3.7.2 Treatment3.7.3 Conduit Cleaning3.7.4 Jacking and Drilling Under Roads and Structures3.7.5 Galvanized Conduit Concrete Penetrations3.7.6 Multiple Conduits3.7.7 Conduit Plugs and Pull Rope3.7.8 Conduit and Duct Withou
14、t Concrete Encasement3.7.8.1 Encasement Under Roads and Structures3.7.9 Duct Encased in Concrete3.7.9.1 Connections to Manholes3.7.9.2 Connections to Existing Underground Structures3.7.9.3 Connections to Existing Concrete Pads3.7.9.4 Connections to Existing Ducts3.7.9.5 Partially Completed Duct Bank
15、s3.7.9.6 Removal of Ducts3.8 CABLE PULLING3.8.1 Cable Lubricants3.9 CABLES IN UNDERGROUND STRUCTURES3.9.1 Cable Tag Installation3.10 CONDUCTORS INSTALLED IN PARALLEL3.11 LOW VOLTAGE CABLE SPLICING AND TERMINATING3.11.1 Terminating Aluminum Conductors3.12 MEDIUM VOLTAGE CABLE TERMINATIONS3.13 MEDIUM
16、VOLTAGE CABLE JOINTS3.13.1 Joints in Shielded Cables3.14 CABLE END CAPS3.15 LIVE END CAPS3.16 FIREPROOFING OF CABLES IN UNDERGROUND STRUCTURES3.16.1 Fireproofing Tape3.16.2 Tape-Wrap3.17 GROUNDING SYSTEMS3.17.1 Grounding Electrodes3.17.2 Grounding Connections3.17.3 Grounding Conductors3.17.4 Ground
17、Cable Crossing Expansion Joints3.17.5 Manhole Grounding3.17.6 Fence Grounding3.18 EXCAVATING, BACKFILLING, AND COMPACTING3.18.1 Reconditioning of Surfaces3.18.1.1 Unpaved Surfaces3.18.1.2 Paving RepairsSECTION 33 71 02.00 20 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted
18、without license from IHS-,-,-3.19 CAST-IN-PLACE CONCRETE3.19.1 Concrete Slabs for Equipment3.19.2 Sealing3.20 FIELD QUALITY CONTROL3.20.1 Performance of Field Acceptance Checks and Tests3.20.1.1 Medium Voltage Cables3.20.1.2 Grounding System3.20.2 Follow-Up Verification- End of Section Table of Cont
19、ents -SECTION 33 71 02.00 20 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-33 71 02.00 20 (August 2008)-Preparing Activity: NAVFAC SupersedingUFGS 33 71 02.00 20 (February 2007)UNIFIED FACILITIES GUIDE SPE
20、CIFICATIONSReferences are in agreement with UMRL dated July 2008*SECTION 33 71 02.00 20UNDERGROUND ELECTRICAL DISTRIBUTION08/08*NOTE: This guide specification covers the requirements for underground electrical work.Edit this guide specification for project specific requirements by adding, deleting,
21、or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to t
22、he technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*NOTE: This guide specification does not cover all po
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS33710200202008UNDERGROUNDELECTRICALDISTRIBUTION 地下 配电 PDF

链接地址:http://www.mydoc123.com/p-984862.html