NAVY MIL-PRF-7115 2 B-2012 CONVERTER AIRCRAFT AC TO DC 200 AMPERE TYPE II CLASS A.pdf
《NAVY MIL-PRF-7115 2 B-2012 CONVERTER AIRCRAFT AC TO DC 200 AMPERE TYPE II CLASS A.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-PRF-7115 2 B-2012 CONVERTER AIRCRAFT AC TO DC 200 AMPERE TYPE II CLASS A.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、AMSC N/A FSC 6130 INCH-POUND MIL-PRF-7115/2B(AS) 11 July 2012 SUPERSEDING MIL-C-7115/2A(AS) 15 August 1986 PERFORMANCE SPECIFICATION SHEET CONVERTER, AIRCRAFT, AC TO DC, 200 AMPERE, TYPE II, CLASS A This specification is approved for use by the Department of the Navy and is available for use by all
2、Departments and Agencies of the Department of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-7115. SCOPE 1. Converter type. The converter is Type II, non-regulated, designed for a nominal 28 VDC output. 2. Converter class. T
3、he converter is class A as modified herein. 3. Part or identifying number (PIN). The converter covered by this specification sheet is identified using the following PIN: Non-regulated converter M7115/2-1 (see figure 1) REQUIREMENTS 1. Dimensions. The dimensions of the converter shall be as shown on
4、figure 1 of this specification sheet. 2. Description. The power characteristics and weight of the converter covered by this specification sheet are shown in table I. Inactive for new design after 10 May 1999 and is no longer used, except for replacement purposes. Provided by IHSNot for ResaleNo repr
5、oduction or networking permitted without license from IHS-,-,-MIL-PRF-7115/2B(AS) 2 TABLE I. Converter description. AC INPUT: (full performance) Voltage Range Frequency Range 108 118 Volts 380 420 Hz DC OUTPUT: Voltage Full Rated Load Current See figure 3 200 Amperes WEIGHT: 17.5 lbs (max) 3. MIL-PR
6、F-7115 variance: The converter shall comply with MIL-PRF-7115 except as follows: 3.1 The following paragraphs are not applicable: 3.5.1.2.1.1a (Full performance subparagraph for Type I regulated converters) 3.5.1.2.4.1 Type I, regulated converters. 3.5.1.2.5 Parallel operation. ( including all subpa
7、ragraphs) 3.5.1.2.6 Output overvoltage protection (Type I, regulated converters only). 3.5.1.6 Pressure drop (blast-cooled converters only). 3.5.2.2 Acceleration. 3.5.2.9 Explosive atmosphere. 3.8.1 Burn-in (Type I regulated converters only). 4.6.2.13 Parallel operation. 4.6.3.3 Pressure drop (blast
8、-cooled converters only). 4.6.3.4 Acceleration. 4.6.3.11 Explosive atmosphere. 4.6.6 Burn-in (Type I, regulated converters only). Table VIII Number of burn-in cycles. Figure 14 Typical burn-in test cycle. 3.2 Modify the following paragraphs of MIL-PRF-7115. 3.4.2.1.1 External electric connections. A
9、dd: “Input and output connections shall be as shown on figure 2 of this specification sheet.” 3.4.3.4 Cooling. Add: “Airflow shall exhaust from the end opposite the connectors, as shown on figure 1 of this specification sheet.” Provided by IHSNot for ResaleNo reproduction or networking permitted wit
10、hout license from IHS-,-,-MIL-PRF-7115/2B(AS) 3 3.4.3.7 Size and weight. Add: “The size and dimensions of the converter shall be as shown on figure 1 of this specification sheet. Unless otherwise specified, all dimensions are in inches and tolerances are .015 inch. Converter weight shall be as requi
11、red in table I of this specification sheet.” 3.5.1.2.1.1b (Full Performance, sub-paragraph b). Delete sentence and substitute: “For Type II Unregulated Converters, the steady state output voltage shall comply with figure 3, Output voltage limits, of this specification sheet.” 3.5.1.2.1.1c (Full Perf
12、ormance, sub-paragraph c). Delete sentence and substitute: “Peak-to-peak ripple voltage shall not exceed 1.5 volts.” 3.5.1.5 Acoustical noise. Sound pressure levels of the converter shall not exceed those listed below. Octave Band Hz Sound Pressure Level dB (ref -0.0002 Microbar) 31 91 63 92 125 93
13、250 94 500 90 1000 87 2000 87 4000 77 3.5.2.1 Temperature altitude. The converter is class A. 3.7.1 Terminals. Delete the paragraph in its entirety and substitute: “The input and output connections shall be marked as shown on figures 1 and 2 of this specification sheet (see 4.6.1).” 3.7.3 Nameplate.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILPRF71152B2012CONVERTERAIRCRAFTACTODC200AMPERETYPEIICLASSAPDF

链接地址:http://www.mydoc123.com/p-981036.html