NAVY MIL-PRF-7032 1 G-2010 INVERTER AIRCRAFT DC TO AC 750 VA 3-PHASE 1000 VA 1-PHASE AND 1000 VA 3-PHASE MULTI-PURPOSE CLASS B [Superseded NAVY MS17406 REV C CANC NOTICE 3 NAVY MS1NOT.pdf
《NAVY MIL-PRF-7032 1 G-2010 INVERTER AIRCRAFT DC TO AC 750 VA 3-PHASE 1000 VA 1-PHASE AND 1000 VA 3-PHASE MULTI-PURPOSE CLASS B [Superseded NAVY MS17406 REV C CANC NOTICE 3 NAVY MS1NOT.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-PRF-7032 1 G-2010 INVERTER AIRCRAFT DC TO AC 750 VA 3-PHASE 1000 VA 1-PHASE AND 1000 VA 3-PHASE MULTI-PURPOSE CLASS B [Superseded NAVY MS17406 REV C CANC NOTICE 3 NAVY MS1NOT.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、 INCH-POUND MIL-PRF-7032/1 10 September 2010 SUPERSEDING MS17406C 14 June 1974 PERFORMANCE SPECIFICATION SHEET INVERTER, AIRCRAFT, DC TO AC, 750 VA 3-PHASE, 1000 VA 1-PHASE, AND 1000 VA 3-PHASE, MULTI-PURPOSE, CLASS B This specification is approved for use by all Departments and Agencies of the Depa
2、rtment of Defense. The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF-7032. SCOPE 1. Inverter class. The inverter is classified as a class B as modified herein. 2. Part or identifying number (PIN). Inverters covered by this specification
3、 sheet are identified using the following PIN: Rotary inverter M7032/1-1, M7032/1-2 (see figure 1) Static inverter M7032/1-3, M7032/1-4, M7032/1-5 (see figure 2) Static inverter M7032/1-6 (see figure 2) APPLICABLE DOCUMENTS 1. Add the following specification to MIL-PRF-7032. 2.2.1 Specifications and
4、 standards. Add the following document: MIL-M-7793/6 Meter, Time Totalizing, Miniature, Digital, 115 V 400 Hz. (Inactive for new design) AMSC N/A FSC 6125 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-7032/1 2 2.3 Non-Government publication
5、s. Add the following documents: SAE-AS31061 Connector, Plug, Electric, Straight, Solder Contacts, AN Type. (DoD adopted) SAE-AS31081 Connectors, Plug, Electric, Solder Contact, 90 Degree, AN Type. (DoD adopted) REQUIREMENTS 1. Description. Power ratings and characteristics of the inverters covered b
6、y this specification sheet are shown in table I. TABLE I. Inverter description. 1/ = Phase 2. M7032/1-1 and /1-2 inverters shall be provided with a time totalizing meter conforming to MIL-M-7793/6. The meter shall be located on the left side of the control box facing the connector end. 3. MIL-PRF-70
7、32 variance: The inverters shall comply with MIL-PRF-7032 except that the following paragraphs of MIL-PRF-7032 shall be modified: 3.4.2.1.1 External electric connections. Delete the last sentence and substitute: “Input and output connections for appropriate single-phase and three-phase operation sha
8、ll be as shown on figure 3 of this specification sheet. 3.4.2.1.1.3 Output voltage jacks. Delete the first sentence and substitute: “One set of placarded pin jacks shall be provided on the inverter as shown on figures 1 and 2 of this specification sheet, between which the output voltage can be measu
9、red.” Part no. Power Rating 1/ Power factor Max weight (lb) Superseding M7032/1-1 750VA, 3/1 0.8 MIN LAG 23 MS17406-1A M7032/1-2 750VA, 3/1 0.95 MIN LEAD 23 MS17406-2A M7032/1-3 750VA, 3 23 MS17406-3 M7032/1-4 1000VA, 1 0.75 MIN LAG 23 MS17406-4 M7032/1-5 1000VA, 1, Low Input Voltage 0.95 MIN LEAD 2
10、3 MS17406-5 M7032/1-6 1000VA, 3 23 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-7032/1 3 3.4.2.2.2.1 Voltage setting. At the end of the paragraph: Add: “For the M7032/1-1 and M7032/1-2 inverters, a means of voltage adjustment shall be loca
11、ted on the connector end above the horizontal centerline of the inverter.” 3.4.3.5 Cooling. Delete the last sentence and substitute the following: “The direction of air flow shall be as follows:” M7032/1-1 Airflow exhaust from center M7032/1-2 Airflow exhaust from connector end M7032/1-3 Airflow exh
12、aust from the end opposite the connectors M7032/1-4 Airflow exhaust from the connector end M7032/1-5 Airflow exhaust from the connector end M7032/1-6 Airflow exhaust from the end opposite the connectors 3.4.3.8 Size and weight. Delete the first sentence and substitute: “The size and dimensions of th
13、e inverters shall be as shown on figures 1 and 2 of this specification sheet. Unless otherwise specified, all dimensions are in inches and tolerances are 0.015 inch. Inverter weights shall be as required in table I of this specification sheet.” 3.5.1.1.a Delete the subparagraph in its entirety and s
14、ubstitute: “The normal input voltage range shall be as required in table II of this specification sheet.” 3.5.1.1.b Delete the subparagraph in its entirety and substitute: “The abnormal input voltage range shall be as required in table II of this specification sheet.” 3.5.1.1.c Delete the subparagra
15、ph in its entirety and substitute: “The low input voltage range shall be as required in table II of this specification sheet and applies only to M7032/1-5 inverter. 3.5.1.3 Output frequency regulation. Delete the second sentence and substitute: “The steady state frequency for rotary inverters, M7032
16、/1-1 and M7032/1-2, shall be as required in table II of this specification sheet. Static inverters shall maintain a steady-state frequency of 400 7 Hertz under all specified input voltages (see 3.5.1.1), load, temperature, and altitude conditions specified (see 4.5.2).” 3.5.1.4 Efficiency. Delete th
17、e first sentence and substitute: “The minimum efficiency of rotary inverters shall be 50 percent for 3-phase and 45 percent for 1-phase inverters (see 4.5.3). ” 3.5.1.7.1 Static inverters. Delete the first sentence and substitute: “The steady-state output voltage limits within two seconds after appl
18、ication of input voltage for conditions 1 through 5 shall be as required in table II of this specification sheet. For the M7032/1-6 inverter only, the output voltage during input power application shall be within and remain within limits of this specification sheet within 400 milliseconds after appl
19、ication of input voltage.” Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-7032/1 4 3.5.1.7.2 Rotary inverters. Add the following new second and third sentences: “The maximum controlled output voltage is condition 6, as required in table II o
20、f this specification sheet. The steady-state output voltage limits for conditions 1 through 5 shall be as required in table II of this specification sheet.” 3.5.1.8.1 Overload. Add the following sentence at the end of the paragraph: “The minimum output voltage during overload conditions is condition
21、 7, as required in table II of this specification sheet.” 3.5.1.10.1 Voltage. Add the following sentence to the end of the paragraph: For M7032/1-6 only, the output voltage modulation shall not exceed 1.0 percent under normal input voltage conditions at full load, half load, and no load, and 1.5 per
22、cent from 24.0 to 26.0 volts DC (see 3.5.1.1 and 4.5.9.1). 3.5.1.16 Acoustical noise. Not applicable. 3.5.2.1 Temperature altitude. Delete the paragraph in its entirety and substitute: “All inverters covered by this specification sheet are class B. The inverter shall be capable of operation without
23、degradation of performance throughout the temperature-altitude range specified in 3.5.2.1.2.” 3.7.1 Terminals. Delete the paragraph in its entirety and substitute: “The input and output connectors and voltage pin jacks shall be marked as shown on figures 1 and 2 of this specification sheet (see 4.5.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILPRF70321G2010INVERTERAIRCRAFTDCTOAC750VA3PHASE1000VA1PHASEAND1000VA3PHASEMULTIPURPOSECLASSBSUPERSEDEDNAVYMS17406REVCCANCNOTICE3NAVYMS1NOTPDF

链接地址:http://www.mydoc123.com/p-981034.html