1、A-A-59008 9399774 0175216 T5T I INCH-POUND I A-A-59008 22 July 1997 COMMERCIAL ITEM DESCRIPTION STRAINERS, SELF-CLEANING, BACKFLUSH TYPE (MANUAL OR AUTOMATED) The General Service Administration has authorized the use of this commercial item description, for all federal agencies. 1. SCOPE 1.1 Score.
2、This commercial item description covers both manual and automated backflush type self-cleaning strainers. 1.2 Intended use. The strainers specified are intended for installation in sea water piping systems on the discharge side of the pump. 2. CLASSIFICATION 2.1 Classification. Backflush type self-c
3、leaning strainers shall be of the following types, classes, styles, and sizes as specified (see 7.1): Type I - Manual. Type II - Automated. Class 150 - 150 pounds per square inch gage (psig) pressure Class 250 - 250 psig pressure rating. rating. Style 1 - Rotational divider, sizes 2, 3, 4, 6, 8, 10,
4、 12, Style 2 - Rotational backwash arm, sizes 2, 3, 4, 6, 8, 10, 14, 16, 20 and 24 inch. 12, 14, 16, 18, 20 and 24 inch. Beneficial comments, recommendations, additions, deletions, clarifications etc. and any other data which may improve this document should be sent to: Commander, SEA 03R42, Naval S
5、ea Systems Command, 2531 Jefferson Davis Hwy, Arlington, VA 22242-5160. AMSC N/A FSC 4730 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A - A-5 9 O O 8 D 9999974 0175
6、217 996 A-A-59 008 3. SALIENT CHARACTERISTICS 3.1 Codes and standards. Strainer shall comply with the applicable requirements of Table I. 3.2 Desian and constxuction. Each strainer shall be of the type, class, style, and size as specified (see 2.1). The self cleaning action shall remove particulate
7、contaminants from the sea water system without interrupting the operation of that system. The straining element shall be cleaned in segments such that the particulate contaminants are flushed free of the strainer. 3.3 Material. The material requirements for all strainer components shall be in accord
8、ance with Table II. TABLE I. Reference data. MIL-F-20042 raised face flanges MIL-M-17059 3.4 Strainina element. The straining element shall be made of one unit. The element shall be of the perforated plate or plate type construction. All seam welds shall be continuous. 3.4.1 Strainino element comtme
9、ssion strenoth test. The straining element shall be tested by applying a differential pressure (outside-inside) across the straining element equal to 100 percent of the specified strainer design pressure for the applicable type and class, using water for a duration of 5 minutes. or less. Differentia
10、l pressure shall be applied in a rapid manner, one minute 3.4.2 Straininu element emansion strenuth test. The straining element shall be tested by applying a differential pressure (inside-outside) across the straining element equal to 100 percent of the specified strainer design pressure for the app
11、licable type and class, using water for a duration of 20 minutes. Differential pressure shall be applied in a rapid manner, one minute or less. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-59008 m 9999974 0375238 822 m . A-A- 5 90 08 3.5 Act
12、uation. Each strainer shall be fitted with a shaft along its rotational axis, which penetrates the compartment cover through a watertight seal. Outside the housing, the shaft shall be capable of being fitted with either a handle (Type I) or an electric motor actuator (Type II). Each type I strainer
13、shall be sized and configured so that maximum required operating force is less than 50 pounds. For certain hazard areas, such as installation in a JP-5 pump room, type II strainer motors shall be explosion proof. TABLE II. Materials reauired for strainers. Part Bodies, covers Col lar, hand1 e self c
14、leaning mechanism Threaded fasteners O II -ring Straining element Mat er i al Copper-nickel NiA1 bronze Cast tin bronze CRES NiA1 bronze NiCu alloy Fluorocarbon CuNi plate NiCu date Applicable documents Remarks ASTM B 369 C96400 ASTM B 148 C95800 ASTM B .61 C92200, ASTM A 276 C31600 ASTM B 127 NO440
15、0 ASTM B 148 C95800 ASTM F 467 N04400, NO4405 ASTM F 468 MIL-R-83248/1 For all except threaded bosses MIL-R-83248/2 Threaded bosses 1 ASTM B 122 C71500 3.6 Self cleanina mechanism. 3.6.1 Stvle 1. The straining element is divided by a vertical partition which yields 2 - halves of a cylindrical elemen
16、t. At the bottom of each half, there is a drain connection which will be used to connect backflush valves at installation. Backflushing is accomplished by rotating the divider handle 180, diverting flow to the clean half of the element, and then opening the drain valve of the dirty half. A portion o
17、f the fluid, flows back through the dirty element freeing the contaminant and allowing the debris to be flushed from the strainer. Fluid use to flush the debris out of the strainer shall not exceed 15% percent of the total flow through the strainer assembly. Strainer shall be fitted with two flushin
18、g connections one for each partitioned straining compartment. 3.6.2 Stvle 2. The straining element is cleaned by a hollow backwash arm which rotates inside the element. Backflushing is accomplished by opening the drain valve, diverting fluid flow back through a portion of the element. The debris flo
19、ws into hollow backwash arm and out of the strainer. The backwash arm then rotates to the next portion of the element. Fluid used to flush the debris out of the strainer shall not exceed 15% percent of the total flow through the strainer assembly. 3 Provided by IHSNot for ResaleNo reproduction or ne
20、tworking permitted without license from IHS-,-,-A-A-59008 D 9999974 OL752L9 769 D A-A- 5 900 8 3.7 Covers. Covers shall be flanged and attached to the body by bolts. Each cover shall effect a positive seal on an O-ring. 3.8 Functional Derformance. Unless otherwise specified (see 7-11, design flow ca
21、pacity, design temperature, and clean pressure drop shall be as specified in Table III. 3.8.1 ODerational cvclina tests. The strainer shall be tested for a total of 600 hours at design pressure and flow rates. once every hour during testing period. At the completion of the 600 hours, compliance with
22、 the required operating force of 50 pounds or less and zero leakage shall be demonstrated. Upon satisfactory completion of this test the unit shall be refurbished to new condition before being offered for delivery. 3.9 EnveoDe dimensions. Envelope dimensions shall be in accordance with Table IV. Str
23、ainer shall be backflushing 3.10 WorkmanshiD. The strainer body and covers shall be of uniform quality and condition, free from blow holes, porosity, hard spots, shrinkage defects, cracks, and other defects. All surfaces shall be smooth and well cleaned. The inside surfaces of strainers shall be wel
24、l cleaned and free from sharp edges. TABLE III. Functional Derformance. 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A- 5 9 O0 8 TABLE IV. EnveloDe dimensions. 4. REGULATORY REQUIREMENTS 4.1 Recovered ma terials . The offeror/contractor is enc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYAA590081997STRAINERSSELFCLEANINGBACKFLUSHTYPEMANUALORAUTOMATED 人工 自动 后流式 过滤器 PDF

链接地址:http://www.mydoc123.com/p-976349.html