1、INCH-POUNDA-A-590063 December 1996COMMERCIAL ITEM DESCRIPTIONINDICATORS, PIPELINE, FLOW, SIGHTThe General Service Administration has authorized the use of this commercialitem description, for all federal agencies.1. SCOPE1.1 Scope. This commercial item description covers sight flow pipelineindicator
2、s intended for installation in drain lines of strainer, where flowindication is necessary for backflush and draining operations.2. CLASSIFICATION2.1 Classification. Sight Flow Pipeline Indicators shall be classified as150, 250 and 300 class, in-line, flanged units as appropriate to ANSI B16.5 andMIL
3、-F-20042.3. SALIENT CHARACTERISTICS3.1 Codes and standards. Sight flow indicators shall comply with theapplicable requirements of ASME Boiler and Pressure Vessel Code Section VIII.3.2 Design. Each sight flow indicator shall be as specified by table I. Sight flow shall be designed as not to obstruct
4、flow of the fluid, is withoutinternal indicator.Beneficial comments (recommendations, additions, deletions) and any pertinentdata which may be of use in improving this document should be addressed to:Commander, SEA 03R42, Naval Sea Systems Command, 2531 Jefferson Davis Hwy,Arlington, VA 22242-5160 b
5、y using the self-addressed Standardization DocumentImprovement Proposal (DD Form 1426) appearing at the end of this document orby letter.AMSC N/A FSC 4730DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.Provided by IHSNot for ResaleNo reproduction or networking permit
6、ted without license from IHS-,-,-A-A-590062TABLE I. Reference data.Equipment/Characteristic DescriptionFluid type Sea water, Fuel oil, Lube oilOperating pressure 400 psi (MAX)Hydrostatic test pressure 600 psi (MAX) Temperature range Normal 70 to 220G45FPiping connections Class 150 and 300, ANSI B16.
7、5 raisedface flanges, straight throughconfiguration150 and 250 rating MIL-F-20042 fullface flanges, straight throughconfigurationShock resistance MIL-S-901, grade AVibration Resistance MIL-STD-167, type 13.3 Material. The material requirements for all sight flow indicatorcomponents shall be in accor
8、dance with table II. Sight flow indicators in seawater service shall utilize non-ferrous material.3.4 Construction. The sight flow indicator is composed of four basiccomponents. The body which provides in-line attachment capability and rigidity tothe sight flow indicator. The glass provides the view
9、ing window to the processflow stream. O-rings compressed to tightly seal the gap and prevent leakingbetween the glass and body. Cover provides a compression surface for the bolts tohold the gasket and glass tightly against the sight flow body.TABLE II. Materials required for sight flow indicator.Par
10、t Material Documents RemarksApplicableBody Stainless Steel ASTM A 351 Gr CF8M70-30 CuNi ASTM B 369 C96400Bronze ASTM B 61 C95800ASTM B 62Glass Borosilicate TemperedThreaded CRES MS17829fastenersASTM F 593 SHNiCu ASTM F 467 N04400, N04405ASTM F 468“O“ rings Fluorocarbon MIL-R-83248/1 Type 1 Class 13.
11、5 Piping connections. Flanges shall be in accordance with therequirements of ANSI B16.5 for stainless steel units and MIL-F-20042 for bronzeunits. Flanges shall be integrally cast with the body as applicable to theworking pressure.Provided by IHSNot for ResaleNo reproduction or networking permitted
12、without license from IHS-,-,-A-A-5900633.6 Envelope dimensions. Envelope dimensions shall be in accordance withtables III and IV.TABLE III. Envelope dimensions for 150 rated sight flow indicators.Sight flow indicator Width Flange to Flange View port I.D.size (inch) (inches) (inches) (inches)1 5.750
13、5.625 1.5002 9.313 7.875 2.8753 11.938 9.375 3.7504 11.625 11.000 4.7506 18.000 14.250 7.0008 21.000 16.125 9.000TABLE IV. Envelope dimensions for 250 and 300 rated sight flow indicators.Sight flow indicator Width Flange to flange View port ID. size (inches) (inches) (inches) (inches)1 6.438 6.875 1
14、.375 2 9.625 8.625 2.1253 13.375 11.375 3.188 4 16.500 13.250 4.2506 23.750 21.375 6.2508 23.750 22.375 6.2503.7 Identification plates. Identification plates shall be provided inaccordance with the requirements of MIL-P-15024 and MIL-P-15024/5, and shallinclude the following:(a) Commercial Item Desc
15、ription (CID) number.(b) Manufacturer.(c) Contract Number.(d) The nominal pipe size of the inlet and outlet connections.(e) Pressure rating.3.7.1 Part numbering of interchangeable parts. The manufacturers partnumber and drawing number shall be the same. All fasteners shall be identified byan industr
16、y part number which identifies both size and material.3.8 Mechanical shock. The complete sight flow indicator assembly shall becapable of withstanding the medium impact shock test specified in 5.7.2.1.3.9 Vibration. The complete sight flow indicator assembly shall be designedand tested to function s
17、atisfactorily under the requirements of MIL-STD-167-1Type 1 environmental vibration.3.10 Workmanship. The body and flanges shall be of uniform quality andcondition, free from blow holes, porosity, hard spots, shrinkage defects, cracks,and other defects. All surfaces shall be smooth and well cleaned.
18、 The insidesurfaces shall be well cleaned and free from sharp edges.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-5900644. REGULATORY REQUIREMENTS4.1 Recovered materials. The offeror/contractor is encouraged to userecovered materials to maximum
19、 extent practicable, in accordance with paragraph23.403 of the Federal Acquisition Regulation (FAR).4.2 Prohibited material. Zinc or cadmium plating shall not be used on anypart of the sight flow indicators.4.3 Mercury exclusion. The sight flow indicators shall be free of mercurycontamination. Durin
20、g the manufacturing process, tests, and examination, theproduct to be offered for acceptance shall not come in direct contact with mercuryor any of its components, nor with any mercury containing device employing asingle boundary of containment.5. QUALITY ASSURANCE PROVISIONS5.1 Product conformance.
21、 The products provided shall meet the salientcharacteristics of this commercial item description, conform to the producers owndrawings, specifications, standards, and quality assurance practices, and be thesame product offered for sale in the commercial market. The government reservesthe right to re
22、quire proof of such conformance.5.2 Classification of inspections. The inspection requirements specifiedherein are classified as follows:(a) First article inspection (see 5.3).(b) Quality conformance inspection (see 5.4).5.3 First article inspection. First article inspection shall consist of onesigh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYAA590061996INDICATORSPIPELINEFLOWSIGHT 视觉 管道 流量 指示器 PDF

链接地址:http://www.mydoc123.com/p-976347.html