NAVY A-A-50623-1994 ALARM SWITCHBOARD TYPE IC SM《IC/SM警报配电盘》.pdf
《NAVY A-A-50623-1994 ALARM SWITCHBOARD TYPE IC SM《IC/SM警报配电盘》.pdf》由会员分享,可在线阅读,更多相关《NAVY A-A-50623-1994 ALARM SWITCHBOARD TYPE IC SM《IC/SM警报配电盘》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、A-A-50623 9999974 OLb5272 980 A-A- 50623 16 September 1994 SUPERSEDING MIL-A-17196E (IN PART) 7 October 1977 (See Note i) COMMERCIAL ITEM DESCRIPTION ALARM SWITCHBOARD TYPE IC/SM The General Services Administration has authorized the use of this commercial item description as a replacement for Type
2、IC/SM Switchboards in MIL-A- 17196E(SH). Abstract. This Commercial Item Description covers requirements for IC/SM Alarm Switchboards which will enable one operator to monitor equipment functions or environmental conditions of remote equipment. IC/SM Alarm Switchboards shall be capable of being conne
3、cted to mechanical, electrical, electronic, electromechanical and environmental-sensing devices. Alarm switchboards shall be such that remote sensors located at each monitor point will provide switch closure to signal the alarm detection circuit of a fault condition. In addition, this circuit will p
4、rovide a supervisory current loop which provides for operational confidence in the remote sensor circuit. Alarm switchboards shall include provisions for remote audible and visual indication of alarm conditions in addition to the central displays. Salient characteristics. 1. Type IC/SM Alarm Switchb
5、oards shall be composed of an ICJSM alarm panel, such as shown in Figures 1 thru 8, and IC/M alarm modules mounted within the alarm panel. 2. General requirements Integral Components. a. Power requirements. The alarm switchboards shall be designed for operation from a normal source of power conformi
6、ng to Type I, 115 V, 60 Hz, 1 phase. A rectifier shall be provided to supply power for the line circuits, lamp flasher , ground detector lamps and pilot lamp. The supervisory voltage shall be 5 +1/-0 Vdc, full wave, rectified (unfiltered) . Beneficial comments, recommendations, additions, deletions,
7、 clarifications, etc. and any other data which may improve this document should be sent by letter to: Commander, Naval Sea System Command, Attn: 03R42, 2531 Jefferson Davis Highway, Arlington, VA 22242-5160. AMSC N/A FSC: 6320 DISTRIBUTION STATEMENT A. Approved for public release; distribution is un
8、limited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A- 50623 A-A-50623 m 9999974 O365273 37 m * FIGURE 1 - IC/SM-4 4 LINE SWITCHBOARD 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-_ A-A-506
9、23 9999974 0365274 753 = asbestos compounds: and asbestos-filled molding compounds Lithium and lithium compounds Magnesium or magnesium alloy Zinc or Zinc alloy Carcinogens Radioactive material Polychlorinated Biphenyl (PCB) Polyvinyl Chloride (PVC), except where used for component leads Mercury or
10、its compounds and amalgams Cadmium c. Preservation. All parts shall be of suitable corrosion resistance material or materials treated in a satisfactory manner to render them adequately resistant to corrosion caused by sea water. d. Painting. Sheet metal and cast enclosures shall be completely painte
11、d, in accordance with the ordering data, in accordance with best commercial practices utilizing latex or epoxy based paints. Composite enclosures (if used) normally shall not be painted. e. Temperature and humidity. Alarm switchboards and alarm modules shall operate without mechanical or electrical
12、damage in any ambient temperature between the limits of O and 50“ C (Centigrade) and with a relative humidity of 95 percent. f. Shock and vibration. For naval procurement all switchboard units shall satisfactorily withstand, without mechanical or electrical damage, Grade (BI, Type A, Class I, Light
13、Weight shock in accordance with MIL-S-901, and vibration testing in accordance with MIL-STD-167, Type 1, Vital. g. Electromagnetic Interference (EMI). For naval procurement switchboard units shall satisfactorily meet the requirements of MIL-STD-461 as demonstrated following the procedures of MIL-STD
14、-462. h. Reliability. IC/SM Alarm Switchboards and IC/M Alarm Modules shall have a Mean Time Between Failure (MTBF) of at least 30K Hours. 3. IC/M Alarm Module. Each remote sensing device in an alarm circuit shall be monitored by a type IC/M module, constructed in accordance with FIGURE 9. Each modu
15、le shall include one set of electrically isolated, normally open contacts which shall close on alarm condition. They shall be suitable for making and breaking an external resistive load of at least 3A at 28 Vdc and shall not be in the completed circuit when the module is operated in the test mode. U
16、pon closure of an alarm sensor, momentary or otherwise, each module shall latch-in and shall not clear even if the alarm sensor re-opens. The switch shall have to be moved to the STANDBY position in order to silence the audible alarm. An alarm condition cleared indication shall be given in the STAND
17、BY switch position alerting the operator to return the switch to NORMAL. a. Moisture proofing. All electronic PC board components shall be conformal coated to ensure operability in a moisture laden environment. b. Weight and size. The maximum weight of the IC/M Module shall not exceed 0.500 Kg nor t
18、he size shown in FIGURE 9. 10 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- A-A-50b23 W 99999Li OLb5282 82T = A- A- 5 O 62 3 4. IC/SM Switchboard. a. Alarm section. The common alarm section shall have the following parts mounted on or in the face
19、of the panel: “me IC/SM Audible speaker. Module lamp dimmer control. Ground lights (two). Switchboard identification plate. Silent alarm switch. Silent alarm lamp. Main power fuse indicator. Extension alarm blown fuse indicator b. Ground Indicators. The ground indicators shall sense an absolute grou
20、nd between the terminal board and the enclosure, with one light connected to indicate a positive ground, and the other connected to indicate a negative ground. c. Supervisory current. A continuous supervisory alarm current, not to exceed 1.2 milliamperes (ma), shall flow through each alarm line modu
21、le. The circuit for the determination of the normal supervisory current shall include a current limiting resistor, installed in the most electrically remote sensing device in the circuit. A single line alarm module shall trigger a supervisory alarm for supervisory current at 0.1 ma, +0.2 ma/-0.05 ma
22、, but no supervisory alarm shall be generated above 0.3 ma. The module shall trigger a normal alarm for 4.0 ma and higher current flow. d. Enclosure. All switchboards shall be enclosed in a dripproof metal, or composite, cabinet. Each panel shall be arranged to hinge out from the left side, such tha
23、t all parts shall be accessible from the front of the cabinet. Terminal strips for connecting the ship cables shall be provided in the rear of the enclosure. All flexing cables to hinged panels shall be designed with a maximum amount of slack to distribute bending over the longest practical length o
24、f cable. The type of conductors, and the method of cabling the conductors shall be specifically designed for flexing service. Electrical connectors for the sensor lines shall be capable of accepting a bare wire connection from the sensor, without requiring the use of plugs or pins. shall be as indic
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYAA506231994ALARMSWITCHBOARDTYPEICSMIC SM 警报 配电盘 PDF

链接地址:http://www.mydoc123.com/p-976320.html