1、*USACE / NAVFAC / AFCESA / NASA UFGS-23 74 33.00 40 (February 2011)-Preparing Activity: NASA SupersedingUFGS-23 74 33 (November 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated January 2011*SECTION TABLE OF CONTENTSDIVISION 23 - HEATING, VENTILATING, AND AIR CO
2、NDITIONINGSECTION 23 74 33.00 40PACKAGED, OUTDOOR, HEATING AND COOLING MAKEUP AIR-CONDITIONERS02/11PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 GENERAL REQUIREMENTSPART 2 PRODUCTS2.1 MANUFACTURED UNITS2.1.1 Window-Type, Packaged, Self-Contained (WAC)2.1.2 Console-Type, Packaged, Self-Contained (CAC
3、)2.1.3 Remote-Split-Type, Packaged, Self-Contained (RSAC)2.1.3.1 Compressor2.1.3.2 Cooling Coil2.1.3.3 Fans2.1.3.4 Casing2.1.3.5 Controls2.1.3.6 Filters2.1.3.7 Air-Cooled Condenser2.1.3.8 Water-Cooled Condenser2.2 COMPONENTS2.2.1 Vibration IsolatorsPART 3 EXECUTION3.1 INSTALLATION3.2 TESTING3.2.1 Qu
4、ality Control3.3 OPERATION AND MAINTENANCE- End of Section Table of Contents -SECTION 23 74 33.00 40 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-23 74 33.00 40 (February 2011)-Preparing Activity: NASA Su
5、persedingUFGS-23 74 33 (November 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated January 2011*SECTION 23 74 33.00 40PACKAGED, OUTDOOR, HEATING AND COOLING MAKEUP AIR-CONDITIONERS02/11*NOTE: This guide specification covers the requirements for packaged-air cond
6、itioning units.Show cooling and dehumidification requirements, capacity, mounting details, power connections, etc. on drawings or schedule.Heating provisions are not included.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, c
7、hoose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change
8、Request (CCR).*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Re
9、ference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.SECTION 23 74 33.00 40 Page 2Provided by IHSNot for Res
10、aleNo reproduction or networking permitted without license from IHS-,-,-References not used in the text are automatically deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this spe
11、cification to the extent referenced. The publications are referred to within the text by the basic designation only.AIR-CONDITIONING, HEATING AND REFRIGERATION INSTITUTE (AHRI)AHRI 450 (2007) Water-Cooled Refrigerant Condensers, Remote TypeANSI/AHRI 210/240 (2008) Performance Rating of Unitary Air-C
12、onditioning R 2008) Load Ratings and Fatigue Life for Ball BearingsAMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS (ASHRAE)ASHRAE 52.1 (1992; Interpretation 1 2007) Gravimetric and Dust-Spot Procedures for Testing Air-Cleaning Devices Used in General Ventilation for Removin
13、g Particulate MatterASHRAE 90.1 - IP (2010) Energy Standard for Buildings Except Low-Rise Residential BuildingsASHRAE 90.1 - SI (2007; Supplement 2008; Errata 2009; Errata 2009; INT 1-3 2009; Errata 2010) Energy Standard for Buildings Except Low-Rise Residential BuildingsASME INTERNATIONAL (ASME)ASM
14、E BPVC SEC VIII D1 (2007; Addenda 2008; Addenda 2009) BPVC Section VIII-Rules for Construction of Pressure Vessels Division 1U.S. DEPARTMENT OF ENERGY (DOE)DOE CE-3 (2001) How to Buy an Energy-Efficient Commercial Unitary Air ConditionerSECTION 23 74 33.00 40 Page 3Provided by IHSNot for ResaleNo re
15、production or networking permitted without license from IHS-,-,-DOE RA-1 (2000) How to Buy an Energy-Efficient Room Air Conditioner1.2 SUBMITTALS*NOTE: Review Submittal Description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals re
16、quired for the project. Keep submittals to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and
17、 can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Army projects, use a code of up to three characters within the submittal tags following the
18、“G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and
19、“PO“ for Project Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects.*Government approval is required for submittals with a “G“ desig
20、nation; submittals not having a “G“ designation are for Contractor Quality Control approval.for information only. When used, a designation following the “G“ designation identifies the office that reviews the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMI
21、TTAL PROCEDURES:SD-02 Shop DrawingsSubmit Fabrication drawings for the following items consisting of fabrication and assembly details to be performed in the factory.Packaged UnitCompressorCooling CoilControlsSECTION 23 74 33.00 40 Page 4Provided by IHSNot for ResaleNo reproduction or networking perm
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NASAUFGS23743300402011PACKAGEDOUTDOORHEATINGANDCOOLINGMAKEUPAIRCONDITIONERS 包装 外加 热和 冷却 组成 空调 PDF

链接地址:http://www.mydoc123.com/p-836593.html