NACE TM0211-2011 Durability Test for Copper Copper Sulfate Permanent Reference Electrodes for Direct Burial Applications (Item No 21257)《直埋用铜 硫酸铜永久性参考电极的耐久性测试 项目编号21257》.pdf
《NACE TM0211-2011 Durability Test for Copper Copper Sulfate Permanent Reference Electrodes for Direct Burial Applications (Item No 21257)《直埋用铜 硫酸铜永久性参考电极的耐久性测试 项目编号21257》.pdf》由会员分享,可在线阅读,更多相关《NACE TM0211-2011 Durability Test for Copper Copper Sulfate Permanent Reference Electrodes for Direct Burial Applications (Item No 21257)《直埋用铜 硫酸铜永久性参考电极的耐久性测试 项目编号21257》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、 Standard Test Method Durability Test for Copper/Copper Sulfate Permanent Reference Electrodes for Direct Burial Applications This NACE International standard represents a consensus of those individual members who have reviewed this document, its scope, and provisions. Its acceptance does not in any
2、 respect preclude anyone, whether he or she has adopted the standard or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not in conformance with this standard. Nothing contained in this NACE International standard is to be construed as granting any right, b
3、y implication or otherwise, to manufacture, sell, or use in connection with any method, apparatus, or product covered by Letters Patent, or as indemnifying or protecting anyone against liability for infringement of Letters Patent. This standard represents minimum requirements and should in no way be
4、 interpreted as a restriction on the use of better procedures or materials. Neither is this standard intended to apply in all cases relating to the subject. Unpredictable circumstances may negate the usefulness of this standard in specific instances. NACE International assumes no responsibility for
5、the interpretation or use of this standard by other parties and accepts responsibility for only those official NACE International interpretations issued by NACE International in accordance with its governing procedures and policies which preclude the issuance of interpretations by individual volunte
6、ers. Users of this NACE International standard are responsible for reviewing appropriate health, safety, environmental, and regulatory documents and for determining their applicability in relation to this standard prior to its use. This NACE International standard may not necessarily address all pot
7、ential health and safety problems or environmental hazards associated with the use of materials, equipment, and/or operations detailed or referred to within this standard. Users of this NACE International standard are also responsible for establishing appropriate health, safety, and environmental pr
8、otection practices, in consultation with appropriate regulatory authorities if necessary, to achieve compliance with any existing applicable regulatory requirements prior to the use of this standard. CAUTIONARY NOTICE: NACE International standards are subject to periodic review, and may be revised o
9、r withdrawn at any time in accordance with NACE technical committee procedures. NACE International requires that action be taken to reaffirm, revise, or withdraw this standard no later than five years from the date of initial publication and subsequently from the date of each reaffirmation or revisi
10、on. The user is cautioned to obtain the latest edition. Purchasers of NACE International standards may receive current information on all standards and other NACE International publications by contacting the NACE International FirstService Department, 1440 South Creek Dr., Houston, Texas 77084-4906
11、(telephone +1 281-228-6200). Approved 2011-06-24 NACE International 1440 South Creek Drive Houston, Texas 77084-4906 +1 281-228-6200 ISBN 1-57590-247-8 2011, NACE InternationalNACE Standard TM0211-2011 Item No. 21257 TM0211-2011 NACE International i _ Foreword Copper/copper sulfate (Cu/CuSO4) perman
12、ent reference electrodes(1) (PREs) have been used for many years to monitor buried structures susceptible to corrosive elements. These Cu/CuSO4PREs vary in both design and construction. They typically consist of pure copper in contact with an aqueous solution saturated with copper sulfate (CuSO4). T
13、his standard test method was developed to assess the relative durability provided by various Cu/CuSO4PRE designs. This standard is intended for PRE users to determine the relative durability of Cu/CuSO4PREs. The test method described in this standard may be used by PRE manufacturers for describing t
14、he performance of their Cu/CuSO4 PREs. The standard should be used by Cu/CuSO4 PRE users for specifying minimum acceptance criteria or for identifying products that may provide a longer service life. This standard was prepared by NACE Task Group (TG) 256, Electrodes, Field-Grade: Test Methods. TG 25
15、6 is administered by Specific Technology Group (STG) 62, Corrosion Monitoring and Measurement Science and Engineering Applications. It is also sponsored by STG 05, Cathodic/Anodic Protection,67*Oil and Gas Production Cathodic Protection, and STG 35, Pipelines, Tanks, and Well Casings. This standard
16、is issued by NACE International under the auspices of STG 62. In NACE standards, the terms shall, must, should, and may are used in accordance with the definitions of these terms in the NACE Publications Style Manual. The terms shall and must are used to state a requirement, and are considered manda
17、tory. The term should is used to state something good and is recommended, but is not considered mandatory. The term may is used to state something considered optional. _ (1) $OVRUHIHUUHGWRDVSHUPDQHQWUHIHUHQFHKDOI -FHOODQGLPSUHFLVHODVSHUPDQHQWUHIHUHQFHFHOOWKHVHUHIH UHQFHHOHFWURGHVKDYHILQLWHOLIHand co
18、uld more preciVHOEHFDOOHGSHUPDQHQWOLQVWDOOHG+RZHYHUWKLVVWDQGDUGXVHVWKHPRUHFRPPRQSHUPDQHQWUHIHUHQFHHOHFWURGH(PRE) nomenclature to describe these. TM0211-2011 ii NACE International _ NACE International Standard Test Method Durability Test for Copper/Copper Sulfate Permanent Reference Electrodes for Di
19、rect Burial Applications Contents 1. General .1 2. Test Equipment and Reagents 1 3. Test Procedure2 References 6 FIGURES Figure 1: Schematic of test apparatus for CuSO4leaching test .3 Figure 2: Schematic of test apparatus for chloride contamination test 4 _ TM0211-2011 NACE International 1 _ Sectio
20、n 1: General 1.1 This standard describes a test method to measure specific physical properties and the relative stability of Cu/CuSO4PREs when they are subjected to specific environmental stresses. These reference HOHFWURGHVZKLOHSHUPDQHQWLQWKHSKVLFDOVHQVH(they are not commonly removed), do exhibit a
21、 finite service life. This test method is intended to provide a measure of the relative durability that may be expected. The test method specifically focuses on the ability of the Cu/CuSO4PRE to (1) resist migration of CuSO4from within the PRE into its surrounding environment and (2) to resist the m
22、igration of chloride from its surrounding environment into the PRE. 1.2 Unique field conditions may alter the durability of Cu/CuSO4PREs. Factors such as temperature, sunlight, and soil contaminants can significantly affect PRE durability. Although consideration of these parameters is outside the sc
23、ope of this standard, they may require consideration in certain field applications. 1.3 Environmental factors must be accounted for while performing durability testing. Articles have been written indicating possible factors resulting in erroneous potential measurements from a half-cell and their rel
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NACETM02112011DURABILITYTESTFORCOPPERCOPPERSULFATEPERMANENTREFERENCEELECTRODESFORDIRECTBURIALAPPLICATIONSITEMNO21257

链接地址:http://www.mydoc123.com/p-835896.html