NACE NO 10-2002 Fiberglass-Reinforced Plastic (FRP) Linings Applied to Bottoms of Carbon Steel Aboveground Storage Tanks (Item No 21093 SSPC-PA 6).pdf
《NACE NO 10-2002 Fiberglass-Reinforced Plastic (FRP) Linings Applied to Bottoms of Carbon Steel Aboveground Storage Tanks (Item No 21093 SSPC-PA 6).pdf》由会员分享,可在线阅读,更多相关《NACE NO 10-2002 Fiberglass-Reinforced Plastic (FRP) Linings Applied to Bottoms of Carbon Steel Aboveground Storage Tanks (Item No 21093 SSPC-PA 6).pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Item No. 21093Joint StandardNACE No. 10/SSPC-PA 6Fiberglass-Reinforced Plastic (FRP) LiningsApplied to Bottoms of Carbon Steel AbovegroundStorage TanksThis NACE International (NACE)/SSPC: The Society for Protective Coatings standard represents aconsensus of those individual members who have reviewed
2、 this document, its scope, andprovisions. It is intended to aid the manufacturer, the consumer, and the general public. Itsacceptance does not in any respect preclude anyone, whether he has adopted the standard or not,from manufacturing, marketing, purchasing, or using products, processes, or proced
3、ures notaddressed in this standard. Nothing contained in this NACE/SSPC standard is to be construed asgranting any right, by implication or otherwise, to manufacture, sell, or use in connection with anymethod, apparatus, or product covered by Letters Patent, or as indemnifying or protecting anyoneag
4、ainst liability for infringement of Letters Patent. This standard represents current technology andshould in no way be interpreted as a restriction on the use of better procedures or materials.Neither is this standard intended to apply in all cases relating to the subject. Unpredictablecircumstances
5、 may negate the usefulness of this standard in specific instances. NACE and SSPCassume no responsibility for the interpretation or use of this standard by other parties and acceptresponsibility for only those official interpretations issued by NACE or SSPC in accordance withtheir governing procedure
6、s and policies which preclude the issuance of interpretations by individualvolunteers.Users of this NACE/SSPC standard are responsible for reviewing appropriate health, safety,environmental, and regulatory documents and for determining their applicability in relation to thisstandard prior to its use
7、. This NACE/SSPC standard may not necessarily address all potentialhealth and safety problems or environmental hazards associated with the use of materials,equipment, and/or operations detailed or referred to within this standard. Users of thisNACE/SSPC standard are also responsible for establishing
8、 appropriate health, safety, andenvironmental protection practices, in consultation with appropriate regulatory authorities ifnecessary, to achieve compliance with any existing applicable regulatory requirements prior to theuse of this standard.CAUTIONARY NOTICE: NACE/SSPC standards are subject to p
9、eriodic review, and may berevised or withdrawn at any time without prior notice. The user is cautioned to obtain the latestedition. NACE and SSPC require that action be taken to reaffirm, revise, or withdraw this standardno later than five years from the date of initial publication.Approved February
10、 2002ISBN 1-57590-129-32002, NACE International and SSPC: The Society for Protective CoatingsNACE International1440 South Creek DriveHouston, TX 77084-4906(telephone +1 281/228-6200)SSPC: The Society for Protective Coatings40 24th Street, Sixth FloorPittsburgh, PA 15222(telephone +1 412/281-2331)Pri
11、nted by NACE InternationalNACE No. 10/SSPC-PA 6NACE International i_ForewordThis standard recommended practice specifies the procedures to design, apply, and inspectfiberglass-reinforced plastic (FRP) linings that are applied internally to the bottom of carbon steelaboveground storage tanks (ASTs).
12、FRP linings are used worldwide to prevent the corrosion anddeterioration of storage tank bottoms in petroleum, petrochemical, and other services. Experiencehas shown that the useful life of an FRP lining may exceed 25 years. API(1)Standard 6531permits aminimum remaining thickness of the tank bottom
13、plate to be 1.25 mm (0.050 in.) when lined with FRPcompared to a thickness of 2.5 mm (0.10 in.) if unlined or lined with a nonreinforced coating systemand not equipped with a tank bottom leak detection system. This standard will serve as a resource forfacility owners preparing specifications to achi
14、eve successful lining applications in ASTs in thepetroleum/petrochemical industry. The practices described are also useful during preparation ofspecifications for ASTs in other services.This joint standard was prepared by the SSPC/NACE Task Group 009 on Fiberglass-ReinforcedPlastic Linings for Above
15、ground Storage Tank Floors. This task group is administered by NACESpecific Technology Group (STG) 80 on Intersociety Joint Coatings Activities, and also sponsored bySTG 03 on Protective Coatings and LiningsImmersion/Buried. This standard is published by NACEunder the auspices of STG 80, and by SSPC
16、._(1)American Petroleum Institute (API), 1220 L St. NW, Washington, DC 20005-4070.NACE No. 10/SSPC-PA 6ii NACE International_Joint StandardNACE No. 10/SSPC-PA 6Fiberglass-Reinforced Plastic (FRP) Linings Applied toBottoms of Carbon Steel Aboveground Storage TanksContents1. General 12. Definitions 13
17、. Lining Materials 24. Storage Tank Preparation 35. Applicator Qualifications and Submissions 36. Surface Preparation . 37. Holding Primer Application . 48. Caulking and Coving Application . 49. Laminate Application 510. Roof Leg Bearing (Striker) Plates 711. FRP Lining Inspection, Testing, and Repa
18、ir . 7References 8Bibliography 9Appendix A: Documents and Standards to Be Used in Conjunction with this Standard 10Figure 1: Squeegee Application of Caulk . 4Figure 2: Schematic of Overlap at Floor Plate or Striker Plate Showing Caulking andSingle Laminate Application 5Figure 3: Schematic of Caulkin
19、g and Single Laminate Applied at Juncture of Sketch Plateand Shell Plate 5Figure 4: Wet-Film Thickness Gauge . 6Table 1: Items Evaluated by Inspector . 8_NACE No. 10/SSPC-PA 6NACE International 1_Section 1: General1.1 Procedures outlined below and detailed in subsequentsections of this standard shal
20、l be followed for the successfulapplication of a FRP lining system.1.1.1 Abrasive blast clean the storage tank bottomand, as a minimum, the lower 60 cm (24 in.) of the tankshell. The owner should confirm that this minimumtank shell height is acceptable. Inspect cleanedsurfaces just prior to primer o
21、r coating application.1.1.2 If required, apply primer to the storage tank floorand the lower 60 cm (24 in.) of the tank shell.1.1.3 Apply caulk to the properly prepared tank floor,deep pits, equipment supports, striker (bearing) plates,and chine angle, as required.1.1.4 Apply resin and glass reinfor
22、cement to the tankbottom and lower shell course. If a two-layer or doublelaminate system is applied, extend the first layer 45 cm(18 in.) up the tank shell and the second 30 cm (12 in.)up the tank shell. At least 15 cm (6 in.) of blasted andprimed shell wall shall be visible above the first coat ofl
23、aminate.1.1.5 Repair defects in the laminate prior to theapplication of the topcoat. (See Section 2.)1.1.6 Apply a topcoat to the laminate applied to thefloor and to the tank shell.1.1.7 During all phases of the tank lining systemapplication, inspection shall be carried out by theapplicator and, whe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NACENO102002FIBERGLASSREINFORCEDPLASTICFRPLININGSAPPLIEDTOBOTTOMSOFCARBONSTEELABOVEGROUNDSTORAGETANKSITEMNO21093SSPCPA6PDF

链接地址:http://www.mydoc123.com/p-835765.html