1、EIA/JEDECPUBLICATIONSignature AnalysisJEP136JULY 1999ELECTRONIC INDUSTRIES ALLIANCEJEDEC Solid State Technology AssociationNOTICEEIA/JEDEC standards and publications contain material that has been prepared, reviewed, andapproved through the JEDEC Board of Directors level and subsequently reviewed an
2、d approvedby the EIA General Counsel.EIA/JEDEC standards and publications are designed to serve the public interest througheliminating misunderstandings between manufacturers and purchasers, facilitatinginterchangeability and improvement of products, and assisting the purchaser in selecting andobtai
3、ning with minimum delay the proper product for use by those other than JEDEC members,whether the standard is to be used either domestically or internationally.EIA/JEDEC standards and publications are adopted without regard to whether or not theiradoption may involve patents or articles, materials, o
4、r processes. By such action JEDEC does notassume any liability to any patent owner, nor does it assume any obligation whatever to partiesadopting the EIA/JEDEC standards or publications.The information included in EIA/JEDEC standards and publications represents a sound approachto product specificati
5、on and application, principally from the solid state device manufacturerviewpoint. Within the JEDEC organization there are procedures whereby an EIA/JEDECstandard or publication may be further processed and ultimately become an ANSI/EIA standard.No claims to be in conformance with this standard may
6、be made unless all requirements stated inthe standard are met.Inquiries, comments, and suggestions relative to the content of this EIA/JEDEC standard orpublication should be addressed to JEDEC Solid State Technology Association, 2500 WilsonBoulevard, Arlington, VA 22201-3834, (703)907-7560/7559 or w
7、ww.jedec.orgPublished by ELECTRONIC INDUSTRIES ALLIANCE 1999Engineering Department2500 Wilson BoulevardArlington, VA 22201-3834This document may be downloaded free of charge, however EIA retains thecopyright on this material. By downloading this file the individual agrees not tocharge or resell the
8、resulting material.PRICE: Please refer to the currentCatalog of JEDEC Engineering Standards and Publications or call Global EngineeringDocuments, USA and Canada (1-800-854-7179), International (303-397-7956)Printed in the U.S.A.All rights reservedPLEASE!DON”T VIOLATETHELAW!This document is copyright
9、ed by the Electronic Industries Alliance and may not bereproduced without permission.Organizations may obtain permission to reproduce a limited number of copiesthrough entering into a license agreement. For information, contact:JEDEC Solid State Technology Association2500 Wilson BoulevardArlington,
10、Virginia 22201-3834or call (703) 907-7559JEDEC Publication No. 136- i-SIGNATURE ANALYSISCONTENTSPage1 Introduction 12 Purpose 23 Scope 24 Definitions 35 Signature analysis procedure for an ongoing process 35.1 Overview 35.2 SA process flow 45.3 Signature analysis definition phase 45.4 SA validation
11、55.5 Revalidation 56 Signature analysis procedure for a finite population 57 Examples 67.1 Finite population case 67.2 Ongoing process 6Annex A An approach of signature analysis risk assessment proceduresfor an ongoing process 7A.1 Statistical terms and variables 7A.2 Statistical derivation of an es
12、timate for 8A.3 Statistical derivation of confidence intervals for A 9Annex B An approach to signature analysis risk assessment proceduresfor a finite population 11Annex C An approach to signature analysis risk assessment proceduresfor a process with correlated failures 13C.1 Statistical terms and d
13、efinitions 13JEDEC Publication No. 136-ii-JEDEC Publication No. 136Page 1SIGNATURE ANALYSIS(From JEDEC Board Ballot JCB-98-124, formulated under the cognizance of the 14.6Committee on Failure Analysis.)1 IntroductionDevice Analysis is a limited resource that should be targeted at solving unknown pro
14、blems,rather than analyzing repetitive failures. Signature Analysis (SA) is a lab resource managementtool in that it provides a formal method of reducing the number of these repetitive failuresrequiring full analysis. Two statistical models are presented, both of which assign a confidencelevel to an
15、y number of units with the same failure characteristics (i.e., signature) and same failuremechanism, allowing the statement “I am A% sure that greater than B% of other parts with thissignature will also have this failure mechanism”. One model is for use when the failingpopulation size is finite and
16、known, and will be referred to as finite population analysis (FPA).It would be used, for example, to define the sampling plan for a low yielding wafer lot, i.e., todetermine how many failing dice from each failure category must be fully analyzed in order toinfer information about that whole wafer lo
17、t. The other model, referred to as ongoing processanalysis (OPA) assumes the population of future fails is unknown or infinite, and would be usedto infer information about failures collected over time from multiple events, lots or labs. The useof two models also allows us to build-in the engineering
18、 bias that we would expect higherconfidence levels when we do failure analysis by inference on finite population failures, than onones collected over time.The backlog of analysis labs often includes device failures for which both the product engineerand analyst know what will be found during analysi
19、s. However, corporate specifications and/orcustomer requirements often dictate that the analysis be performed anyway. There is a need to beable to assign a failure mechanism (with a statistically determined confidence level) to devicesthat are analyzed by inference to historical data.There is a desi
20、re to promote a common definition of this system of analysis by inference, usingthe same statistical techniques, and to recognize that it is a formal means of doing failureanalysis.JEDEC Publication No. 136Page 22 PurposeThe purposes of these guidelines are the following:(a) To define a process of a
21、nalyzing failures by inference to previous traditional analyses ofdevices with the same failure characteristics, using a statistical and quantitative approach.(b) To provide statistical models for assigning confidence levels to analysis by inference.(c) To help gain acceptance of analysis by inferen
22、ce techniques through consensus ofterminology and methodology.(d) To provide examples of its use.3 ScopeThis method of analysis by inference may be applied to customer returns, failures from qualityconformance testing, reliability failures, qualification failures, and devices from engineeringexperim
23、ents and yield issues.Analysis by inference may be used either when the failing population is known and finite, (todefine a yield analysis sampling plan of a wafer lot, for example), or when the failing populationis unknown and assumed to be infinite.Using SA does not necessarily imply that the root
24、 cause is known or understood, nor does itnecessarily imply that a corrective action will or should take place, but SA can be used inconjunction with other programs that address these needs.It is not the intention of this document to do the following:(a) Define acceptable confidence levels.(b) Defin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- JEDECJEP1361999SIGNATUREANALYSIS 信号 分析 PDF