ITU-T V 54-1988 LOOP TEST DEVICES FOR MODEMS《用于调制解调器的回路测试设备-电话网络上的数据交流 第XVII研究组 第17页》.pdf
《ITU-T V 54-1988 LOOP TEST DEVICES FOR MODEMS《用于调制解调器的回路测试设备-电话网络上的数据交流 第XVII研究组 第17页》.pdf》由会员分享,可在线阅读,更多相关《ITU-T V 54-1988 LOOP TEST DEVICES FOR MODEMS《用于调制解调器的回路测试设备-电话网络上的数据交流 第XVII研究组 第17页》.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、INTERNATIONAL TELECOMMUNICATION UNION)45G134 6 TELECOMMUNICATIONSTANDARDIZATION SECTOROF ITU$!4!G0G0#/-5.)#!4)/./6%2G0G04(%G0G04%,%0(/.%G0G0.%47/2+,/0G0G04%34G0G0$%6)#%3G0G0 amended at Geneva, 1980,Malaga-Torremolinos, 1984 and at Melbourne, 1988)1 IntroductionThe CCITT,consideringthe increasing use
2、 being made of data transmission systems, the volume of the information circulating on datatransmission networks, the savings to be made by reducing interruption time on such links, the importance of being ableto determine responsibilities in maintenance questions for networks, of necessity involvin
3、g several parties, and theadvantages of standardization in this field,unanimously declares the following:The locating of faults can be facilitated in many cases by looping procedures in modems. These loops allowlocal or remote measurements, analogue or digital, to be carried out optionally by the Ad
4、ministrations and/or usersconcerned.2 ScopeThis Recommendation specifies modem loop testing procedures for the following cases:- for synchronous mode of operation over point-to-point leased circuit, multipoint, tandem and generalswitched telephone network (GSTN) connections;- for start-stop mode of
5、operation over point-to-point leased circuit and GSTN connections.3 Definition of the loopsFour loops are defined (numbered 1 to 4) and their locations as seen from DTE A are shown in Figure 1/V.54. Asymmetrical set of four loops could exist as seen from DTE B.2 Fascicle VIII.1 - Rec. V.543.1 Loop 1
6、This loop is used as a basic test on the operation of the DTE, by returning transmitted signals to the DTE forchecking. The loop should be set up inside the DTE as close as possible to the interface.While the DTE is in the loop 1 test condition:- transmitted data (circuit 103) are connected to recei
7、ved data (circuit 104) within the DTE;- circuit 108/1 or 108/2 must be in the same condition as it was before the test;- circuit 105 must be in the OFF condition;- circuit 125 should continue to be monitored by the DTE so that an incoming call can be given priority overa routine loop test.Interchang
8、e circuit 103 as presented to the DCE must be in the binary 1 condition.The conditions of the other interchange circuits are not specified but they should if possible permit normalworking. The transmitter timing information, in particular if it comes from the DCE, will continue to be sent (seeRecomm
9、endation V.24, 4.6.2).Note - When circuits 108 and 105 are not used by the DTE (for applications on leased lines, for example) theDCE will not be informed of the test condition. This is considered acceptable provided that the remote station is notdisturbed.3.2 Loop 3This is a local loop established
10、in analogue mode as close as possible to the line to check the satisfactoryworking of the DCE. The loop should include the maximum number of circuits used in normal working (in particular thesignal conversion function, if possible) which may in some cases necessitate the inclusion of devices for att
11、enuatingsignals, for example.The establishment of the loop presents no difficulty when using a 4-wire line, except in certain cases in whichparts of the line equalization system are removed from service.For certain 2-wire lines the loop may be obtained by simple unbalance of the hybrid transformer.W
12、hile the DCE is in the loop 3 test condition:- the transmission line is suitably terminated, as required by national regulations;- all interchange circuits are operated normally, except in the case of 2-wire half-duplex operation where themandatory clamping involving circuits 105 and 109 (as specifi
13、ed in Recommendation V.24, 4.3.2 a) isdisabled;- circuit 125 should continue to be monitored by the DTE so that an incoming call can be given priority overa routine loop test, after abandoning the loop 3 condition;- no signal is transmitted to line on the data channel.Since most interchange circuits
14、 operate normally, a diagram of interchange circuit operation sequence is notpresented.Note 1 - In certain switched networks the loop 3 procedure may clear the connection due to national regulations.During the loop 3 condition, however, the DCE must not be switched to the line, if not already connec
15、ted.Note 2 - In 4-wire point-to-point connections circuit 105 may be continuously ON. If in such cases synchronousmodems are used, no test data should be transmitted until circuits 106, 109 and 142 are in the ON condition.3.3 Loop 2Loop 2 is designed to permit station A or the network to check the s
16、atisfactory working of the line (or part of theline) and of the DCE B. It can only be used with a duplex DCE; the application to the backward channel is left forFascicle VIII.1 - Rec. V.54 3further study. Pseudo loop 2 may be defined for a half-duplex DCE and will be specified in the Recommendation
17、relatingto the DCE concerned.The establishment of the loop will be effective when the control is applied, regardless of the condition ofcircuit 108 presented by the DTE associated with the DCE in which the loop is set up.While the DCE B is in the loop 2 test condition:- circuit 104 is connected inte
18、rnally in the DCE to circuit 103 (see Note 1);- circuit 104 to the DTE is maintained in the binary 1 condition;- circuit 109 is connected internally in the DCE to circuit 105 (see Note 1);- circuit 109 to the DTE is maintained in the OFF condition;- circuit 106 to the DTE is maintained in the OFF co
19、ndition;- circuit 107 to the DTE is maintained in the OFF condition;- circuit 115 is connected internally in the DCE to circuit 113 if provided (see Note 1);- circuit 115 and circuit 114, if provided, to the DTE continue to function.Note 1 - For the internal DCE connections, the electrical signal ch
20、aracteristics may either be that of theinterchange circuits or that of the logic level used inside the DCE.Note 2 - In certain applications, it may not be desirable to connect circuit 115 to circuit 113. In these cases aflexible buffer between circuits 104 and 103 might be recommended. Alternatively
21、, changes in the transmit clock may bedone in a phase-continuous manner.3.4 Loop 4This loop arrangement is only considered in the case of 4-wire lines. Loop 4 is designed for the maintenance oflines by Administrations using analogue-type measurements. When receiving and transmitting pairs are connec
22、ted intandem, such a connection cannot be measured as a data circuit (conformity with a line characteristic curve, forexample).In the loop position the two pairs are disconnected from the DCE and are connected to each other through asymmetrical attenuator designed to prevent any oscillation of the c
23、ircuit (the loop, therefore, does not include any of theamplifiers and/or distortion correctors used in the DCE). The value of the attenuator will be fixed by each Administrationin compliance with Recommendation G.122 1.Loop 4 may be established inside the DCE or in a separate unit.When loop 4 is in
24、side the DCE, and while in the test condition, the DCE presents circuits 107 and 109 to theDTE in the OFF condition and circuit 142 is in the ON condition. When loop 4 is in a separate unit, these conditions aredesirable but not mandatory.4 Loop controlTwo (non-exclusive) types of control might be p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTV541988LOOPTESTDEVICESFORMODEMS 用于 调制解调器 回路 测试 设备 电话 网络 数据 交流 XVII 研究 17 PDF

链接地址:http://www.mydoc123.com/p-804372.html