ITU-T O 6-1988 1020 Hz REFERENCE TEST FREQUENCY《1020赫兹参考测试频率-规格为测量设备(第4研究组)共2页》.pdf
《ITU-T O 6-1988 1020 Hz REFERENCE TEST FREQUENCY《1020赫兹参考测试频率-规格为测量设备(第4研究组)共2页》.pdf》由会员分享,可在线阅读,更多相关《ITU-T O 6-1988 1020 Hz REFERENCE TEST FREQUENCY《1020赫兹参考测试频率-规格为测量设备(第4研究组)共2页》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、INTERNATIONAL TELECOMMUNICATION UNION)45G134 / TELECOMMUNICATIONSTANDARDIZATION SECTOROF ITU30%#)&)#!4)/.3G0G0&/2G0G0-%!352).G0G0%15)0-%.4G0G0(ZG0G02%&%2%.#%G0G04%34G0G0&2%15%.#9)45G134G0G0RecommendationG0G0/ (Extract from the “LUEG0“OOK)NOTES1 ITU-T Recommendation O.6 was published in Fascicle VI.4
2、 of the Blue Book. This file is an extract from theBlue Book. While the presentation and layout of the text might be slightly different from the Blue Book version, thecontents of the file are identical to the Blue Book version and copyright conditions remain unchanged (see below).2 In this Recommend
3、ation, the expression “Administration” is used for conciseness to indicate both atelecommunication administration and a recognized operating agency. ITU 1988, 1993All rights reserved. No part of this publication may be reproduced or utilized in any form or by any means, electronic ormechanical, incl
4、uding photocopying and microfilm, without permission in writing from the ITU.Fascicle IV.1 - Rec. 0.6 1Recommendation O.6Fascicle IV.1 - Rec. 0.61020 Hz REFERENCE TEST FREQUENCY(Melbourne, 1988)1 IntroductionThe intent of this Recommendation is to specify a single nominal reference frequency of 1020
5、 Hz in order toprovide guidance to manufacturers and Administrations in the design and operation of new equipment and systems. ThisRecommendation is not intended to have an effect on existing equipment or systems except where modifications arerequired to allow for interworking. For instance, an olde
6、r analogue exchange would need to be provided with newreference frequency capability if circuits were provided between it and digital exchanges.2 Test frequencies on circuits routed over PCM systemsThe selection of a suitable test frequency is a major consideration when testing circuits routed over
7、PCMsystems. An error in level measurement can arise on circuits routed over PCM systems if the test frequency is a sub-multiple of the PCM sampling rate. This error can be nearly as great as 0.15 dB at 800 Hz and 0.20 dB at 1000 Hzwith a sampling rate of 8000 Hz employing 8-bit coding. In addition,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTO619881020HZREFERENCETESTFREQUENCY1020 赫兹 参考 测试 频率 规格 测量 设备 研究 PDF

链接地址:http://www.mydoc123.com/p-800437.html