ITU-T O 163-1988 EQUIPMENT TO PERFORM IN-SERVICE MONITORING ON 1544 kbit s SIGNALS《对1544 kbit s信号进行在线业务监测的设备-测试设备规范 第5页》.pdf
《ITU-T O 163-1988 EQUIPMENT TO PERFORM IN-SERVICE MONITORING ON 1544 kbit s SIGNALS《对1544 kbit s信号进行在线业务监测的设备-测试设备规范 第5页》.pdf》由会员分享,可在线阅读,更多相关《ITU-T O 163-1988 EQUIPMENT TO PERFORM IN-SERVICE MONITORING ON 1544 kbit s SIGNALS《对1544 kbit s信号进行在线业务监测的设备-测试设备规范 第5页》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、INTERNATIONAL TELECOMMUNICATION UNION)45G134 / TELECOMMUNICATIONSTANDARDIZATION SECTOROF ITU30%#)b) detect and accumulate the counts of occurrences of loss of frame alignment;c) measure and display the error performance of 24-frame multiframe signals by monitoring the cyclicredundancy check (CRC-6)
2、bits and performing a CRC-6 procedure in accordance withRecommendation G.704 1 and as described below;d) detect and display the various alarm or fault conditions including loss of signal, loss of frame alignment,and other alarm conditions indicated by specific bit patterns.1.3 The equipment may opti
3、onally provide the following additional capabilities:a) detect and display the code violations in the 1544 kbits signal in accordance with Recommen-dation O.161;b) provide an external interface for extracting the information bits conveyed in any selected channel timeslot;c) provide an external inter
4、face for extracting the 4 kbit/s data link bits defined in the 24-frame multiframestructure;d) provide an external interface for extracting the signalling bits in the 12-frame and 24-frame structures.2 Input requirements2.1 InterfaceThe monitoring equipment shall be capable of operating with a test
5、load impedance at a 1544 kbit/s interfaceas defined in 2 of Recommendation G.703 2. It shall also be capable of operating when connected to protectedmonitoring points1)(see also Recommendation G.772 3).2.2 Input impedance2.2.1 Input impedance (resistive) 100 ohms2.2.2 Return loss (20 kHz to 1600 kHz
6、) 20 dB2.3 Input sensitivityAs a minimum, the monitoring equipment shall operate properly in the line terminating mode over the range ofbit rates, pulse shapes and signal levels defined in 2 of Recommendation G.703 2. It shall also be equipped with anadditional gain to compensate for the isolation l
7、oss incurred at protected monitoring points1)(see also Recommen-dation G.772 3). A signal level indicator, or other means, shall be provided for the proper adjustment of inputsensitivity._1)The specification of protected monitoring points is under study in SG XV and SG IV2 Fascicle IV.4 - Rec. O.163
8、2.4 Input jitter toleranceThe monitoring equipment shall be able to tolerate input jitter specified in Table 2/G.824 4 withoutdegradation of measuring accuracy.2.5 Input line codesThe monitoring equipment is intended for use with both AMI and B8ZS line codes. The instrument shall havethe capability
9、to select either AMI or B8ZS, through a switch or other appropriate means. The instrument should indicatewhen it is receiving B8ZS when switched to the AMI mode, and vice versa.3 Detection, measurement, and indication requirements3.1 Detection and indication of fault conditions3.1.1 Loss of line sig
10、nalUnder study.3.1.2 Loss of frame alignmentThe equipment shall recognize the loss of frame alignment as defined in Recommendation G.706 5, and anappropriate indication shall be given.3.1.3 Recovery of frame alignmentThe procedure for determining recovery of frame alignment shall be in accordance wi
11、thRecommendation G.706 5. When frame recovery is complete, the indication of loss of frame alignment shall cease.3.1.4 Alarm indication signal (AIS) from an upstream failureThe equipment shall recognize the presence of an alarm indication signal (AIS) indicating an upstream failure,and an appropriat
12、e indication shall be given. The binary equivalent of the AIS corresponds to an all ones signal. Thestrategy for the detection of the presence of an AIS shall be such that with a high probability, it is detected even in thepresence of a code violation ratio of 1 in 1000.3.1.5 Distant alarm indicatio
13、n signal (DAIS)The equipment shall recognize the presence of distant alarm indication signal as defined inRecommendation G.733 6, 4.2.4 for both 12-frame and 24-frame multiframe signals, and an appropriate indicationshall be given. The strategy for the detection of the presence of this distant alarm
14、 indication signal shall be such that witha high probability, it is detected even in the presence of a code violation ratio of 1 in 1000.3.2 Frame alignment signal (FAS) error performance measurements3.2.1 Count of errored secondsThe equipment shall be capable of counting the number of one second in
15、tervals in which one or more errorsoccur in the FAS bits associated with the 12-frame or 24-frame structures as defined in Recommendation G.704 1. Thenumber of errored seconds in a selectable time period (see 4.1) shall be counted and displayed. The equipment shallestablish one-second intervals inde
16、pendent of the occurrence of errors.3.2.2 Count of errorsThe equipment shall be capable of counting the number of FAS bit errors occurring in a selectable timeperiod (see 4.1).3.3 CRC-6 error performance monitoring3.3.1 Count of errored secondsThe equipment shall be capable of counting the number of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTO1631988EQUIPMENTTOPERFORMINSERVICEMONITORINGON1544KBITSSIGNALS 1544 KBITS 信号 进行 在线 业务 监测 设备 测试 规范

链接地址:http://www.mydoc123.com/p-800387.html