1、INTERNATIONAL TELECOMMUNICATION UNION)45G134 / TELECOMMUNICATIONSTANDARDIZATION SECTOROF ITU30%#) amended Malaga-Torremolinos, 1984)1 GeneralThis specification describes an in-service code violation monitor for the first and second level in the digitaltransmission hierarchy.The pseudoternary codes t
2、o be monitored are alternate mark inversion (AMI), high density bipolar with amaximum of 3 consecutive zeros (HDB3), B6ZS and B8ZS.2 Definition of code violation1)2.1 AMITwo consecutive marks of the same polarity. This may not be the absolute number of errors.2.2 HDB3Two consecutive bipolar violatio
3、ns of the same polarity. This may not be the absolute number of errors.2.3 B6ZSTwo consecutive marks of the same polarity excluding violations caused by the zero substitution code. Thismay not be the absolute number of errors.2.4 B8ZSTwo consecutive marks of the same polarity excluding violations ca
4、used by the zero substitution code. Thismay not be the absolute number or errors.3 Input signal3.1 InterfaceThe code violation monitor shall be capable of operating at the following bit rates and corresponding interfacecharacteristics as described in the appropriate paragraphs of Recommendation G.70
5、3 1:a) 1544 kbit/s;b) 6312 kbit/s;c) 2048 kbit/s;d) 8448 kbit/s.3.2 Instrument operation3.2.1 The instrument may be equipped to monitor only one or two of the listed codes and operate at the appropriatebit rates for those codes.3.3 Input sensitivity3.3.1 The instrument is required to operate satisfa
6、ctorily under the following input conditions.3.3.1.1 Input impedances and levels in accordance with Recommendation G.703 1.3.3.1.2 The instrument shall also be capable of monitoring at protected test points on digital equipment. Therefore, ahigh impedance input and/or additional gain of 30 dB (40 dB
7、 see Note) shall be provided to compensate for the loss atthe monitoring points already provided on some equipment._1)According to the definitions of code violations in this Recommendation it should be taken into account that the code violationmonitor will not detect zero sequences which violate the
8、 relevant coding rules.2 Fascicle IV.4 - Rec. O.161Note As an option for instruments operating at an interface of 1544 kbit/s corresponding to theRecommendation cited in 1, the additional gain, where provided, shall be 40 dB.3.3.1.3 Additionally, the instrument is required to operate satisfactorily,
9、 in both the terminated and monitor mode,when connected to an interface output in accordance with Recommendation G.703 1 via a length of cable which canhave an insertion loss of 0 dB to 6 dB at the half bit rate of the signal. The insertion loss of the cable at other frequencieswill be proportional
10、to f.3.4 Input impedance3.4.1 The instrument shall have a return loss better than 20 dB under the conditions listed in Table 1/O.161.TABLE 1/O.1613.5 Signal input gating3.5.1 The instrument shall incorporate a sampling circuit, operated from the incoming digital signal, such that theinstrument sense
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTO1611988INSERVICECODEVIOLATIONMONITORSFORDIGITALSYSTEMS 数字 系统 在线 业务 代码 破坏 监测器 测试 设备 规范 PDF

链接地址:http://www.mydoc123.com/p-800381.html