ITU-T L 57-2003 Air-assisted installation of optical fibre cables (Study Group 6)《光缆的空气辅助安装系列L 建造 安装和电缆保护以及外部设备其它元素的研究组》.pdf
《ITU-T L 57-2003 Air-assisted installation of optical fibre cables (Study Group 6)《光缆的空气辅助安装系列L 建造 安装和电缆保护以及外部设备其它元素的研究组》.pdf》由会员分享,可在线阅读,更多相关《ITU-T L 57-2003 Air-assisted installation of optical fibre cables (Study Group 6)《光缆的空气辅助安装系列L 建造 安装和电缆保护以及外部设备其它元素的研究组》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、 INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.57TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (05/2003) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT Air-assisted installation of optical fibre cables ITU-T Recommendation L.57 ITU-T Rec. L.57 (05
2、/2003) i ITU-T Recommendation L.57 Air-assisted installation of optical fibre cables Summary This Recommendation describes air-assisted methods for installation of optical fibres cables in ducts. These methods can be used to install micro cables into mini tubes, or jacketed cables into ducts or cond
3、uits. Installing conditions and equipment required shall be different in each case. Source ITU-T Recommendation L.57 (2003) was prepared by ITU-T Study Group 6 (2001-2004) and approved under the WTSA Resolution 1 procedure on 14 May 2003. ii ITU-T Rec. L.57 (05/2003) FOREWORD The International Telec
4、ommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications. The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them
5、with a view to standardizing telecommunications on a worldwide basis. The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics. The approval of ITU-T R
6、ecommendations is covered by the procedure laid down in WTSA Resolution 1. In some areas of information technology which fall within ITU-Ts purview, the necessary standards are prepared on a collaborative basis with ISO and IEC. NOTE In this Recommendation, the expression “Administration“ is used fo
7、r conciseness to indicate both a telecommunication administration and a recognized operating agency. Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure e.g. interoperability or applicability) and compliance with the Recom
8、mendation is achieved when all of these mandatory provisions are met. The words “shall“ or some other obligatory language such as “must“ and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any pa
9、rty. INTELLECTUAL PROPERTY RIGHTS ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property
10、Rights, whether asserted by ITU members or others outside of the Recommendation development process. As of the date of approval of this Recommendation, ITU had received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementor
11、s are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database. ITU 2003 All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU. ITU-T Rec. L.57 (
12、05/2003) iii CONTENTS Page 1 Introduction 1 2 References. 1 3 Installation of jacketed cables in ducts . 1 3.1 Considerations about elements when installing cable 1 3.2 Variants of air-assisted installation 2 3.3 Operations. 3 4 Installation of microcables in minitubes. 4 Appendix I Indian experienc
13、e: Installation of Optical Fibre Cables (OFC) by Air blowing method 5 ITU-T Rec. L.57 (05/2003) 1 ITU-T Recommendation L.57 Air-assisted installation of optical fibre cables 1 Introduction Air-assisted installation is based on forcing a continuous high-speed airflow along the cable with an air sourc
14、e. Moving air force pushes the cable and makes it advance forward at a typical speed supported by the equipment. Generally, the load on the cable is an order of magnitude lower than the typical force involved with other installation methods, like pulling techniques, reducing installation hazards. Ad
15、ditionally, with this technique, bends in duct run are not as important a matter of concern as they are in pulling techniques, so that installation speed increases and longer lengths of cable can be installed. Cables are installed without virtual stress, leaving the cable relaxed in the duct upon co
16、mpletion of the installation. There are several variants of installation: with/without a piston at the front end of the cable, or with a leaking piston. For variants without a piston, there is no pulling force at the front end of the cable: air flow exerts a distributed force along the entire cable.
17、 In addition, the connection to a pulling cord is not needed. 2 References The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publication, the editions indicated were valid. A
18、ll Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the currently valid ITU-T Recommendations is r
19、egularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation. 1 ITU-T Recommendation L.1 (1988), Construction, installation and protection of telecommunication cables in public networks. 2 ITU-T Recommendation
20、L.10 (2002), Optical fibre cables for duct and tunnel applications. 3 ITU-T Recommendation L.12 (2000), Optical fibre joints. 4 ITU-T Recommendation L.35 (1998), Installation of optical fibre cables in the access network. 3 Installation of jacketed cables in ducts 3.1 Considerations about elements w
21、hen installing cable 3.1.1 Cable duct The combination of duct parameters and materials are critical in determining the installation requirements of specific cable designs when using air-assisted techniques (e.g., air tightness, circular shape, friction coefficient, wall thickness, etc.). Maximum duc
22、t diameter depends on the type of machine used. Inner duct diameter shall guarantee correct installation of cable. 2 ITU-T Rec. L.57 (05/2003) 3.1.2 Cable Maximum installation length is influenced by the stiffness and weight of the cable. A very flexible cable can only be pushed with a low pushing f
23、orce and it might be necessary to use an additional element at the front end of the cable, like an open shuttle, which allows the air stream to flow through its centre bore and exert a low pulling force at the front end of the cable. This element might also be necessary when the diameter of the cabl
24、e is very small compared with the internal diameter of the duct. When using a piston at the front end of the cable, a pulling force is exerted on the cable. In this case, maximum cable stress, which depends on the cable design, shall not be exceeded. Cable sheath friction coefficient and friction pr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTL572003AIRASSISTEDINSTALLATIONOFOPTICALFIBRECABLESSTUDYGROUP6 光缆 空气 辅助 安装 系列 建造 电缆 保护 以及 外部设备 其它

链接地址:http://www.mydoc123.com/p-799549.html