ARMY MIL-PRF-62625 B-2009 VALVE FUEL-DRAIN《放油阀》.pdf
《ARMY MIL-PRF-62625 B-2009 VALVE FUEL-DRAIN《放油阀》.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-PRF-62625 B-2009 VALVE FUEL-DRAIN《放油阀》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 Comments, suggestions, or questions on this document should be addressed to U.S. Army RDECOM, Tank Automotive Research, Development and Engineering Center, ATTN: RDTA-EN/STND/TRANS MS #268, 6501 E. 11 Mile Road, Warren, MI 48397-5000 or emailed to DAMI_STANDARDIZATIONconus.army.mil. Since contact i
2、nformation can change, you may want to verify the currency of this address information using the ASSIST Online database at http:/assist.daps.dla.mil. AMSC N/A FSC 2910 METRIC MIL-PRF-62625B(AT) 6 November 2009 SUPERSEDING MIL-PRF-62625A(AT) 8 December 1995 PERFORMANCE SPECIFICATION VALVE, FUEL-DRAIN
3、 This specification is approved for use by the U.S. Army Tank Automotive Research, Development and Engineering Center (TARDEC), Research, Development and Engineering Command (RDECOM), Department of the Army, and is available for use by all Departments and Agencies of the Department of Defense. 1. SC
4、OPE 1.1 Scope. This specification covers a check valve used for draining fuel. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification o
5、r recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether or not they are list
6、ed. 2.2 Government documents. 2.2.1 Specifications, standards and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (
7、see 6.2). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-62625B(AT) 2 FEDERAL SPECIFICATIONS A-A-52557 - Fuel Oil, Diesel; for Posts, Camps and Stations DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-DTL-5624 - Turbine Fuel, Aviation, Grades JP-4
8、and JP-5 MIL-PRF-7024 - Calibrating Fluids, Aircraft Fuel System Components (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2.2 Other Government
9、 documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). US ARMY TACOM
10、 DRAWINGS 12302407 - Valve, Fuel-Drain (Copies of this drawing are available from DAMI_STANDARDIZATIONconus.army.mil or U.S. Army RDECOM, Tank Automotive Research, Development and Engineering Center, ATTN: RDTA-EN/STND/TRANS MS #268, 6501 E. 11 Mile Road, Warren, MI 48397-5000.) 2.3 Non-Government p
11、ublications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (see 6.2). AMERICAN SOCIETY FOR QUALITY (ASQ) ANSI/ASQ Z1.4 - Sampling Procedures and Tables for
12、 Inspection by Attributes (Copies of this document are available from www.asq.org or American Society for Quality, 600 North Plankinton Avenue, Milwaukee, WI 53203.) 2.4 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this documen
13、t and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-
14、,-MIL-PRF-62625B(AT) 3 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a first article sample shall be subjected to first article inspection in accordance with 4.2. 3.2 Materials. Materials used shall be in accordance with the manufacturers materials specifications for valves. The mater
15、ials shall be capable of meeting all of the operational and environmental requirements specified herein (see 4.4.1). 3.2.1 Metallic materials. Metallic materials shall be either corrosion resistant or protected to prevent corrosion (see 4.4.1). 3.2.2 Compatibility. The valve shall be capable of func
16、tioning with, and shall not deteriorate from contact with, the following fluids (see 4.4.1). a. Turbine fuel per MIL-DTL-5624 b. Calibration fluid per MIL-PRF-7024 c. Diesel fuel oil per A-A-52557 3.2.3 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environment
17、ally preferable materials should be used to the maximum extent possible, provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle costs (see 4.4.1). 3.3 Design and construction. 3.3.1 Envelope. The envelope of the val
18、ve shall be as specified on drawing 12302407. 3.4 Performance. 3.4.1 Open-close pressure. When pressure is applied in the closed flow path, the valve shall close between 55 kiloPascal (kPa) and 75 kPa (between 8 and 11 pounds per square inch gage (psig). When the air pressure is decreased, the valve
19、 shall open between 75 and 55 kPa (between 11 and 8 psig) (see 4.4.4). 3.4.2 Proof pressure. The valve shall be capable of operating at 2068 kPa (300 psig) and shall be capable of withstanding a proof pressure of 3103 kPa (450 psig) with no signs of damage or external leakage (see 4.4.5). 3.4.3 Burs
20、t pressure. The valve shall be capable of withstanding a burst pressure of 5171 kPa (750 psig) without rupturing. The valve is not required to be operational after meeting this requirement (see 4.4.6). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-
21、MIL-PRF-62625B(AT) 4 3.4.4 Leakage. Leakage of calibration fluid conforming to MIL-PRF-7024, type II, or an equivalent, at 4137 138 kPa (600 20 psig) through the closed flow path shall be not more than 0.5 cubic centimeters per minute (cm3/min). There shall be no external leakage (see 4.4.7). 3.4.5
22、Drainage. The valve shall drain calibration fluid conforming to MIL-PRF-7024, type II, or an equivalent, at a rate of not less than 3500 cm3/min with a pressure of 3.45 kPa (0.5 psig) (see 4.4.8). 3.4.6 Environmental. The valve shall not be damaged and shall meet the requirements of 3.4.1 to 3.4.5 d
23、uring exposure to the following environments (see 4.4.9): a. Ambient temperature range of -51 to 371 degrees Celsius (C) (-60 to 700 degrees Fahrenheit (F). b. Fluid temperature range of -51 to 371 C (-60 to 700 F). 3.5 Identification and markings. The valve shall be permanently marked for identific
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF62625B2009VALVEFUELDRAIN 放油阀 PDF