ITU-T L 49-2003 Micro-trench installation technique (Study Group 6)《微型沟槽安装技术系列L 建造 安装和电缆保护以及外部设备其它元素》.pdf
《ITU-T L 49-2003 Micro-trench installation technique (Study Group 6)《微型沟槽安装技术系列L 建造 安装和电缆保护以及外部设备其它元素》.pdf》由会员分享,可在线阅读,更多相关《ITU-T L 49-2003 Micro-trench installation technique (Study Group 6)《微型沟槽安装技术系列L 建造 安装和电缆保护以及外部设备其它元素》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、 INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.49TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (03/2003) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT Micro-trench installation technique ITU-T Recommendation L.49 ITU-T Rec. L.49 (03/2003) i ITU-T
2、 Recommendation L.49 Micro-trench installation technique Summary This Recommendation describes the so-called micro-trenching technique, that allows installing underground cables at a shallow depth, in small grooves. The advantages of this technique over conventional cable laying technologies lie ess
3、entially in its speed of execution, lower cost, significantly lower environmental impact and limited disruption to road and, as a consequence of the previous items, easiness in obtaining permits for the occupation of public area. Source ITU-T Recommendation L.49 was approved by ITU-T Study Group 6 (
4、2001-2004) under the ITU-T Recommendation A.8 procedure on 29 March 2003. ii ITU-T Rec. L.49 (03/2003) FOREWORD The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications. The ITU Telecommunication Standardization Sector (ITU-T) is a p
5、ermanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldwide basis. The World Telecommunication Standardization Assembly (WTSA), which meets every four years, esta
6、blishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics. The approval of ITU-T Recommendations is covered by the procedure laid down in WTSA Resolution 1. In some areas of information technology which fall within ITU-Ts purview, the necessary st
7、andards are prepared on a collaborative basis with ISO and IEC. NOTE In this Recommendation, the expression “Administration“ is used for conciseness to indicate both a telecommunication administration and a recognized operating agency. Compliance with this Recommendation is voluntary. However, the R
8、ecommendation may contain certain mandatory provisions (to ensure e.g., interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provisions are met. The words “shall“ or some other obligatory language such as “must“ and the negative equivalent
9、s are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party. INTELLECTUAL PROPERTY RIGHTS ITU draws attention to the possibility that the practice or implementation of this Recommendation may involve the use of a claimed
10、 Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside of the Recommendation development process. As of the date of approval of this Recommendation, ITU had rece
11、ived notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementors are cautioned that this may not represent the latest information and are therefore strongly urged to consult the TSB patent database. ITU 2003 All rights reserved
12、. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU. ITU-T Rec. L.49 (03/2003) iii CONTENTS Page 1 Scope 1 2 Installation requirements 1 2.1 Preparatory steps 1 2.2 Groove cutting 2 2.3 Groove cleaning and drying . 2 2.4 Cable laying
13、2 2.5 Cable protection 2 2.6 Closing the cable groove 2 2.7 Cable jointing . 3 2.8 Cable maintenance 3 3 Application criteria . 4 3.1 Entry to manholes or chambers 4 3.2 Entry to buildings . 4 3.3 Required documentation. 5 ITU-T Rec. L.49 (03/2003) 1 ITU-T Recommendation L.49 Micro-trench installati
14、on technique 1 Scope This Recommendation: gives advice on general requirements of the installation procedure; gives some application criteria. 2 Installation requirements The micro-trenching technology shall be applied on routes that involve asphalted surfaces such as roads or sidewalks with a base
15、of compact material (asphalt or concrete). Its advantages over conventional cable laying technologies lie essentially in its speed of execution, major reduction in infrastructure deployment costs, and significantly lower impact on the environment and road traffic. Protection against impact resulting
16、 from road repairing is not possible due to the shallow depths used in micro-trenching techniques. It is therefore essential to carefully plan the routes on which these techniques are to be used in order to provide long-term stability of the routes. Micro-trenching is normally carried out by cutting
17、 a groove in the asphalt to a little depth (better if not less than 7 cm), but without penetrating past the asphalt layer. Care must be taken to avoid cutting entirely through the asphalt, as this could cause the pavement along the sides of the groove to crack or split. This precaution must be borne
18、 in mind in all cases where there is no lateral protection on one or both sides of the groove which can prevent the asphalt layer from shifting, and particularly in cases where micro-trenching is performed along the edge of a road with no curb or sidewalk. In such cases, the groove shall normally be
19、 located at a suitable distance (e.g., at least one metre) from the edge of the road. Groove width may vary (e.g., 10-15 mm) in accordance with the diameter of the cable laid. The cable should meet exacting demands as to crush resistance and, in particular, temperature resistance, which is needed wh
20、en sealing the cable in the groove with hot bitumen. The bitumen temperature during the sealing operation can reasonably vary between 100 C and 170 C. The optical fibres are preferably enclosed in a metallic (e.g., copper) tube filled with a suitable filling compound and surrounded by a PE jacket. T
21、here are currently different cable types in use, containing different numbers of fibres and with different outside diameters. The cable can be manufactured and supplied in long lengths; in city networks it is however often convenient to use short or matching lengths particularly for crossing under r
22、oad or rail. 2.1 Preparatory steps As is customary, a detailed survey of the route must be carried out, the purpose of which is to identify the work required to be done before starting cable installation operations. Such work could include, for instance, the preparation at bridges, or at road or rai
23、l crossings. Further, it is necessary to determine closure locations and section ends. The route subsoil, i.e., asphalt thickness, road or sidewalk composition may have to be investigated by test drillings. 2 ITU-T Rec. L.49 (03/2003) 2.2 Groove cutting Micro-trenching is performed using an asphalt
24、cutting machine. Cutting speed will depend on the type of machine used. The route shall be free from sharp changes in direction. Where such changes are unavoidable, they shall be made by means of cuts angled as illustrated in Figure 1. L.049_F01Figure 1/L.49 Example of sharp change in route directio
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTL492003MICROTRENCHINSTALLATIONTECHNIQUESTUDYGROUP6 微型 沟槽 安装 技术 系列 建造 电缆 保护 以及 外部设备 其它 元素 PDF

链接地址:http://www.mydoc123.com/p-799525.html