1、 International Telecommunication Union ITU-T L.63TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (10/2004) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT Safety practice for outdoor installations ITU-T Recommendation L.63 ITU-T Rec. L.63 (10/2004) i
2、 ITU-T Recommendation L.63 Safety practice for outdoor installations Summary This Recommendation has the objective to establish safety practices for personnel and operations to provide protection against fire in outdoor telecommunications installations and in shared infrastructures. Source ITU-T Rec
3、ommendation L.63 was approved on 7 October 2004 by ITU-T Study Group 6 (2001-2004) under the ITU-T Recommendation A.8 procedure. ii ITU-T Rec. L.63 (10/2004) FOREWORD The International Telecommunication Union (ITU) is the United Nations specialized agency in the field of telecommunications, informat
4、ion and communication technologies (ICTs). The ITU Telecommunication Standardization Sector (ITU-T) is a permanent organ of ITU. ITU-T is responsible for studying technical, operating and tariff questions and issuing Recommendations on them with a view to standardizing telecommunications on a worldw
5、ide basis. The World Telecommunication Standardization Assembly (WTSA), which meets every four years, establishes the topics for study by the ITU-T study groups which, in turn, produce Recommendations on these topics. The approval of ITU-T Recommendations is covered by the procedure laid down in WTS
6、A Resolution 1. In some areas of information technology which fall within ITU-Ts purview, the necessary standards are prepared on a collaborative basis with ISO and IEC. NOTE In this Recommendation, the expression “Administration“ is used for conciseness to indicate both a telecommunication administ
7、ration and a recognized operating agency. Compliance with this Recommendation is voluntary. However, the Recommendation may contain certain mandatory provisions (to ensure e.g. interoperability or applicability) and compliance with the Recommendation is achieved when all of these mandatory provision
8、s are met. The words “shall“ or some other obligatory language such as “must“ and the negative equivalents are used to express requirements. The use of such words does not suggest that compliance with the Recommendation is required of any party. INTELLECTUAL PROPERTY RIGHTS ITU draws attention to th
9、e possibility that the practice or implementation of this Recommendation may involve the use of a claimed Intellectual Property Right. ITU takes no position concerning the evidence, validity or applicability of claimed Intellectual Property Rights, whether asserted by ITU members or others outside o
10、f the Recommendation development process. As of the date of approval of this Recommendation, ITU had not received notice of intellectual property, protected by patents, which may be required to implement this Recommendation. However, implementers are cautioned that this may not represent the latest
11、information and are therefore strongly urged to consult the TSB patent database at http:/www.itu.int/ITU-T/ipr/. ITU 2008 All rights reserved. No part of this publication may be reproduced, by any means whatsoever, without the prior written permission of ITU. ITU-T Rec. L.63 (10/2004) iii CONTENTS P
12、age 1 Scope 1 2 References. 1 3 Construction infrastructure . 1 3.1 Duct systems. 2 3.2 Cable tunnels 2 3.3 Manholes 2 3.4 Sewage infrastructure installations. 3 4 Outside plant network. 3 4.1 Aerial network 3 4.2 Buried network . 3 5 Outside plant equipment. 4 6 Shared infrastructure. 4 Appendix I
13、Ukraine experience Fire safety in the duct system . 5 I.1 Duct system of Ukraine 5 I.2 Fire safety in manholes, collectors and tunnels 8 Appendix II Brazilian experience Safety of personnel for installation in infrastructures of power lines distribution 9 ITU-T Rec. L.63 (10/2004) 1 ITU-T Recommenda
14、tion L.63 Safety practice for outdoor installations 1 Scope The objective of this Recommendation is to provide guidance to administrations on safety practice for personnel and fire protection for outdoors telecommunications installations such as duct systems, manholes, tunnels, aerial, underground a
15、nd buried networks, subscribers, equipments for outside plant, and networks in sewage infrastructures. 2 References The following ITU-T Recommendations and other references contain provisions which, through reference in this text, constitute provisions of this Recommendation. At the time of publicat
16、ion, the editions indicated were valid. All Recommendations and other references are subject to revision; users of this Recommendation are therefore encouraged to investigate the possibility of applying the most recent edition of the Recommendations and other references listed below. A list of the c
17、urrently valid ITU-T Recommendations is regularly published. The reference to a document within this Recommendation does not give it, as a stand-alone document, the status of a Recommendation. ITU-T Recommendation K.11 (1993), Principles of protection against overvoltages and overcurrents. ITU-T Rec
18、ommendation K.13 (1988), Induced voltages in cables with plastic-insulated conductors. ITU-T Recommendation K.25 (2000), Protection of optical fibre cables. ITU-T Recommendation K.26 (1988), Protection of telecommunication lines against harmful effects from electric power and electrified railway lin
19、es. ITU-T Recommendation K.51 (2000), Safety criteria for telecommunication equipment. ITU-T Recommendation K.58 (2003), EMC, resistibility and safety requirements and procedures for co-located telecommunication installations. ITU-T Recommendation K.59 (2003), EMC, resistibility and safety requireme
20、nts and procedures for connection to unbundled cables. ITU-T Recommendation K.64 (2004), Safe working practices for outside equipment installed in particular environments. ITU-T Recommendation L.20 (1996), Creation of a fire security code for telecommunication facilities. ITU-T Recommendation L.21 (
21、1996), Fire detection and alarm systems, detector and sounder devices. ITU-T Recommendation L.22 (1996), Fire protection. 3 Construction infrastructure For the purpose of this Recommendation, the construction infrastructure is considered to be any of the following outdoor installations associated wi
22、th the outside plant. 2 ITU-T Rec. L.63 (10/2004) 3.1 Duct systems In selecting permanent locations for underground structures, future road developments and plans of others utilities should be considered. Manholes should be located away from road intersections, for safety of workers and the public.
23、Use bottom ducts first, use outside ducts first. In the construction or maintenance of duct lines, the projects must first be analysed for compliance with all the security procedures demanded by the administration for workmanship, and full planning information along the route to be constructed or re
24、newed. Complete design plans should be obtained of all the existing installations, including topological and soil information; in addition, safety and signalling supplies and standard shoring and mechanical equipment should be made available. In the case of existing water, fuel, gas or energy distri
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITUTL632004SAFETYPRACTICEFOROUTDOORINSTALLATIONSSTUDYGROUP6 发行 户外 安装 安全 程序 系列 建造 电缆 保护 以及 外部设备 其它 元素

链接地址:http://www.mydoc123.com/p-799566.html