1、 - - MIL-PRF-62539A = 9999906 2057976 Lisb pAETRIc I MIL-PRF-6253 9A 3 1 December 1997 SUPERSEDING 22 April 1987 MIL-M-62539(AT) PERFORMANCE SPECIFICATION MODULE, STARTER LOW VOLTAGE PROTECTIVE SYSTEM This specification is approved for use by the U.S. Army Tank-automotive and Armaments Command, Depa
2、rtment of the Army, and is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers a low voltage protection module to protect engine starter motor. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are spec
3、ied in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. We every effort has been made to ensure the completeness of this list, document users are cautioned that they
4、 must meet a specified requirement documents cited in sections 3 and 4 of this specification, whether or nut they are listed. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: U.S. Army Tank-autom
5、otive and Armaments Command, ATTN: AMSTA-TR-E/BLUE, Warren, MI 48397-5000, by using the Standardization Document Improvement Proposal D Form 1426) appearing at the end of this document, or by letter. AMSC N/A FSC 2920 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
6、Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-6253 9A 2.2 Government documents. 2-21 Soecications. standards. and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein.
7、 Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation (see 6.2). SPECIFICATIONS DEPARTMENT OF DEFENSE MIL-STD-8 10 - Environmental Test Met
8、hods (see 4.2.1). (Unless otherwise indicated, copies of the above specifications, standards, and handbooks are available fiom the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19 1 1 1-5094.) 2.2.2 Other Government documents. drawings. and publications. The
9、following other Government documents, drawings, and publications form a part of this document to the extent specified hereh. Unless otherwise specified, the issues are those cited in the solicitation DRAWINGS ARMY 11668620 - Module, Starter Low Voltage Protective System (intefice). (Copies of these
10、drawings are available from the U.S. Army Tank-automotive and Armaments Command, ATTN: AMSTA-TR-EBLUE, Warren, MI 48397-5000.) 2.3 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in
11、 this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a sample shall be subjected to fkst article inspection in accordance with 4.4. 2 Provided by IHSNot for ResaleNo reproductio
12、n or networking permitted without license from IHS-,-,- MIL-PRF-62539A Ob 2057978 TL9 MIL-PRF-62539A 3.2 Design. Materials. and manufacturing; processes. Unless otherwise specified, the design, materials, and manufacturing process selection shall be the prerogative of the contractor as long as all a
13、rticles submitted to the government My meet the operating, interface, ownership and support, and operating environment requirements specified. 3.3 Operatinn requirements. Each module shall provide the following fimctional, operational, and performance capabilities. 3.3.1 Performance. The module shal
14、l perform as specified herein through the range of 0-34 volts (V) direct current (dc). Nominal battery voltage to the module shall be 24 V dc. Voltage measurements shall be relative to ground. 3.3.1.1 Batterv voltage sensing. The module shall permit continuous variable voltage up to 34 V dc from the
15、 battery to the starter. Continuity shall be provided between pins B and D when voltage greater than 1 1.75 f 1 V dc is applied to pin A with the module grounded. When less than 11.75 f 1 V dc fiom the battery is applied to pin A, continuity between pins B and D shall be interrupted after a 500 f 50
16、 millisecond (ms) delay. Momentary fluctuations down to below the “break” point, as low as 5 V dc during the 500 ms delay shall not cause continuity between pins B and D to be interrupted. When continuity between pins B and D is interrupted due to low voltage, it shall be re-established and maintain
17、ed oniy by removing the power fi-om pin A for 2 f 1 seconds (s) and applying voltage greater than 11.75 f 1 V dc again to pin A. 3.3.1.2 Generator voltage sensing. Continuity between pins C and D shall be prevented when voltage applied to pin C is greater than 17 f 1 V dc. When continuity between pi
18、ns B and D has been stopped because of high voltage at pin C, the module shail be reset by removing power fiom pins A and C for 2 f 1 s and applying voltage greater than 11.75 f 1 up to 34 V dc to pin A. 3.3.1.3 Power rating. The module shall withstand a continuous current draw of 50 amperes (A) and
19、 withstand surges to 100 A (at 24 V dc) through pins B and D. 3.3.1.4 Polarity protection. Performance shall not be impaired by an incident of reverse polarity when the module is operated with a negatively grounded electrical system utilizing electrical storage batteries. 3.3.1.5 Time delav. When 12
20、 V dc or less are applied to pin A with the case grounded, there will be a time delay of 500 ms before interruption of continuity between pins B and D 3.3.1.6 Starter switch bounce. The module shall function normdy when a signal that has a simulated switch wave form is applied to pin A. 3.3,1.7 Diel
21、ectric strength. Leakage of current through circuit insulation to ground shall not be greater than 100 mA when 1000 volts root mean square (V rms) are applied between the 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- MIL-PRF-bZ539A 9999906 20579
22、79 955 H MIL-PRF-6253 9A case and either pins B or D with the case ground wire disconnected and pins A and C connected to ground. 3.4 Interface requirements. 3.4.1 Envelope, mounting and connection interface. The low voltage protection module shall conform to the envelope dimensions, the bolt hole l
23、ocations and size and the electrical connection location and interface (see 3.4.4) as specified on drawing 11668620. 3.4.2 Interchangeability. Ail modules including mounting and connecting provisions shaii be completely interchangeable. 3.4.3 Mechanical interface. The module shall be constructed to
24、operate in any mounting attitude. 3.4.4 Electrical interface. Electrical connector pins to the utilizing electrical system shall be designated as follows. Connector Pin Function Battery Voltage Sensor Relay Input Generator Voltage Sensor Relay Output Ground Connector Pin Designation A B C D Case 3.4
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF62539A1997MODULESTARTERLOWVOLTAGEPROTECTIVESYSTEM 电压 保护 系统 组件 PDF

链接地址:http://www.mydoc123.com/p-447579.html