1、 Rec. ITU-R SM.1056-1 1 RECOMMENDATION ITU-R SM.1056-1 Limitation of radiation from industrial, scientific and medical (ISM) equipment (Question ITU-R 70/1) (1994-2007) Scope This Recommendation provides limits of radiation from various ISM devices and gives advice on how to use the limits in Public
2、ation 11 of International Special Committee on Radio Interference (CISPR). The ITU Radiocommunication Assembly, considering a) that No. 1.15 of the Radio Regulations (RR) defines ISM applications (of radio-frequency energy) as operation of equipment or appliances designed to generate and use locally
3、 radio-frequency energy for industrial, scientific, medical, domestic or similar purposes, excluding applications in the field of telecommunications; b) that ISM equipment has the potential to cause harmful interference to radiocommunication services and applications throughout the spectrum; c) that
4、 for the optimum use of the frequency spectrum, it is necessary to lay down limits of radiation from ISM equipment outside the bands designated for their use; d) that due to the different operating environments and characteristics of ISM equipment several categories of limits are necessary; e) that
5、radio services operating in the bands designated for use by ISM equipment prior to WARC-79 are required to accept harmful interference and that radiation limits are necessary in all other bands to protect radio services; f) that radiation from ISM equipment may be costly and technically difficult to
6、 suppress and thus development of suppression requirements must take into consideration physical, technological, economic, operational and safety aspects of ISM usage to avoid unnecessarily severe measures; g) that equipment meeting the radiation limits, which are compromise values, may in some circ
7、umstances cause harmful interference; and, there needs to be provisions for measures to be taken to eliminate or reduce interference in individual cases; h) that the legal and administrative provisions differ in different countries and thus administrations have different methods of applying and enfo
8、rcing limits; j) that the International Electrotechnical Commission/International Special Committee on Radio Interference (IEC/CISPR) has developed limits and taken into account the principles outlined in e) and f) and the requirements to harmonize the procedures for the control of interference in o
9、rder to eliminate technical barriers to trade; 2 Rec. ITU-R SM.1056-1 k) that the interference potential depends on the location of ISM equipment within the users premises and that the measuring distance and the point of reference for in situ measurements have to be taken into account; l) that sever
10、e difficulties could arise if different limits were to be recommended by different international bodies for the same class of equipment, noting a) that, for ISM applications, the frequencies typically used by ISM equipment and some current and future ISM applications are shown in Annex 1; b) that, a
11、lthough the ITU has designated specific frequency bands for ISM applications, other operating frequencies are also being used where practical constraints do not permit the usage of the designated bands; c) that CISPR Publication 23 “Determination of limits for industrial, scientific and medical equi
12、pment” provides details of the derivation of limits; d) that information technology equipment (ITE) which use RF energy have not been considered by the CISPR as ISM equipment and CISPR Publication 22, contain a guide for the application of limits and methods of measurements for ITE; e) that RF light
13、ing device operating in the ISM frequency bands 2.45 and 5.8 GHz (and 915 MHz band for Region 2 as defined by the RR) have been considered as ISM equipment in CISPR Publication 11, and other type lighting devices are covered in CISPR Publication 15, recognizing a) that Resolution 63 (Rev.WRC-03) res
14、olves that to ensure that radiocommunication services are adequately protected, studies are required on the limits to be imposed on the radiation from ISM equipment within the frequency bands designated in the Radio Regulations for this use and outside of those bands, in close collaboration with CIS
15、PR; b) that Resolution 952 (WRC-03) resolves to invite CISPR to use the definition of ISM application as show in No. 1.15 of RR, until a new definition is developed in ITU-R in collaboration with CISPR, recommends 1 that administrations may use the latest edition of CISPR Publication 11, including a
16、mendments, as a guide for the application of limits and methods of measurements for ISM devices, in order to protect radiocommunications; 2 that continued cooperation with the CISPR should be initiated to ensure that radiocommunication needs are fully taken into consideration. Rec. ITU-R SM.1056-1 3
17、 Annex 1 Industrial, scientific and medical (ISM) applications 1 Introduction This Annex includes the ITU definition of ISM applications, a list of frequencies typically used by ISM equipment and describes some current and future ISM applications. 2 ISM applications According to RR No. 1.15, ISM app
18、lication is the operation of equipment or appliances designed to generate and use locally radio-frequency energy for industrial, scientific, medical, domestic or similar purposes, excluding applications in the field of telecommunications. A partial list of ISM applications and equipment include: Ind
19、uction heating equipment (below 1 MHz) domestic induction cookers metal melting billet heating tube welding soldering and brazing component heating spot welding selective surface heat treating of metal parts semiconductor crystal growing and refining seam bonding of autobody surfaces package sealing
20、 heating strip steel for galvanizing, annealing and paint drying RF dielectric heating equipment (1-100 MHz) veneer and lumber drying textile drying fibreglass drying paper and paper coating drying plastic pre-heating plastic welding and moulding food post baking and drying meat and fish thawing fou
21、ndry core drying glue drying film drying adhesive curing material preheating Medical equipment short-wave and microwave diathermy and hyperthermia equipment electrical surgical units (ESU) magnetic resonance imaging (MRI) ultrasonic diagnostic imaging Microwave equipment (above 900 MHz) domestic and
22、 commercial microwave ovens food tempering, thawing and cooking UV paint and coating curing rubber vulcanization pharmaceutical processing Miscellaneous equipment RF excited arc welders spark erosion equipment Laboratory and scientific equipment signal generators measuring receivers frequency counte
23、rs flow meters spectrum analysers weighing machines chemical analysis machines electronic microscopes switched mode power supplies (not incorporated in an equipment) 4 Rec. ITU-R SM.1056-1 2.1 Current applications The frequencies currently employed for industrial, scientific, medical and other non-c
24、ommunications applications cover a very wide spectrum including frequencies other than those designated by the RR. A number of ISM equipments use frequencies of undefined tolerance and stability and some of them use frequencies allocated to the safety services and radionavigation services. Table 1 p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ITURSM105612007LIMITATIONOFRADIATIONFROMINDUSTRIALSCIENTIFICANDMEDICALISMEQUIPMENT 来自 工业 科学 医学 ISM 设备

链接地址:http://www.mydoc123.com/p-793961.html