INTERN TMS 1050-2009 Flexible Steel Hose《柔性钢软管》.pdf
《INTERN TMS 1050-2009 Flexible Steel Hose《柔性钢软管》.pdf》由会员分享,可在线阅读,更多相关《INTERN TMS 1050-2009 Flexible Steel Hose《柔性钢软管》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2009 by Navistar, Inc. APRIL 2009 Page 1 of 7 NAVISTAR, INC. TMS (TRUCK MATERIAL SPECIFICATION) NUMBER: T
2、MS-1050 TITLE: Flexible Steel Hose CURRENT REV No.: 0904 DATE: April 2009 WRITTEN/EDITED BY: Materials Engineering APPROVED BY: Materials Engineering SUPERSEDES ISSUE DATED: August 2008 PRINTED COPIES OF THIS DOCUMENT MUST BE VERIFIED FOR CURRENT REVISION This specification may involve hazardous mat
3、erials, equipment, and procedures. This specification does not purport to address all of the safety issues associated with its use. The user is responsible to consult appropriate safety and health practices and to determine the applicability of regulatory limits prior to use. Change Notice: Revised
4、Section 4.1 on material requirements. Reference: Keywords: Exhaust Pipe; Flexible Pipe; Flexible Hose; Flex Pipe 1.0 APPLICATION This specification covers two types of flexible steel pipe/hose used for making connections between pipes used in the exhaust system. The pipe described in this document i
5、s not to be used when raw fuel is present in the exhaust gas traveling through the piping; bellows per TMS-1068 should be specified when this is the case. 2.0 SCOPE This specification covers requirements for the material, construction, dimensions, quality, leakage, installation, design guidance, sou
6、rce approval and quality control, for both types of hose. TYPE I - ID Controlled TYPE II - OD Controlled THIS SPECIFICATION REPLACES ENGINEERING DRAWING AM-76710. References on existing drawings to AM-76710 for materials, construction, dimensions, installation, etc., are superseded by this specifica
7、tion. 2.1 Restricted Chemical Substances Effective January 1, 2007, all product supplied to the requirements of this specification must comply with the requirements of the CEMS B-50 specification. 3.0 REFERENCE DOCUMENTS Unless otherwise specified the latest issue of all referenced standards shall a
8、pply. The following specifications and standards are referenced in this specification. Quality System Standard ISO 9001or TS-16949 NAVISTAR Engineering Dwg. AM-82853 NAVISTAR Engineering Design Std A-16 NAVISTAR Engineering Dwg. WCL-7400 NAVISTAR Manufacturing Std MS-D-13 NAVISTAR Engineering Drawin
9、g AD-6955 CFR Title 29, Part 1910 NAVISTAR CEMS B-50 CFR Title 40, Part 205 NAVISTAR TMS-1068 NAVISTAR Engineering Dwg. AM-76710 NAVISTAR CEMS A-37 Copyright Navistar International Corporation Provided by IHS under license with INTERNNot for ResaleNo reproduction or networking permitted without lice
10、nse from IHS-,-,-NUMBER: TMS-1050 TITLE Flexible Steel Hose REVISION: 0904 This document is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2008 by Navistar, Inc. APRIL 2
11、009 Page 2 of 7 4.0 REQUIREMENTS 4.1 Material 4.1.1 For 4-inch O.D. hose or larger: Type 302, Type 304, or Type 321 stainless steel per CEMS A-37, cold rolled stainless steel strip 0.017-0.020 inch thick, Finish No. 2D, 2B, or BA. 4.1.2 For hose greater than 2.5” O.D. and less than 4” O.D.: Type 409
12、 or 300 series Stainless Steel per CEMS A-37. Exception: Pulling force for a 15% min extension shall be a maximum of 45 pounds (see Construction Requirement, Section 4.2). 4.1.3 For 2.5” O.D. hose: 300 series stainless steel per CEMS A-37 (Optional: Type 439 stainless steel) 4.2 Construction Hose sh
13、all be constructed of an interlocked series of metal convolutions tightly wound about an axis so as to require a maximum pulling force of 35 pounds* to achieve an extension of 15% from the compressed length. Extension shall be 2.5 inches per foot minimum from the compressed position. Hose may be pro
14、vided unpacked or packing with copper or stainless steel wire is permissible; asbestos packing shall not be used. End coils shall be tack-welded (both ends) after cutting to length (refer to Section A.1.1). Both ends shall have all burrs removed. * Note: There is a direct correlation between the min
15、imum allowable pulling force to achieve a 15% extension and the maximum allowable leakage rate. The max allowable leakage rate constrains the minimum pulling force. 4.3 Leakage Rate Maximum leakage rate of hose in the one-half extended position shall be two standard cubic feet of air per minute per
16、foot of hose at 4 psig. (Note: This requirement is necessary in order to meet 80dB pass- by noise testing; reference CFR Title 40, Part 205.) 4.4 Dimensions Bore Diameter - Type I only ID Tolerance inch mm inch mm 1.50 38.0 +0.030/-0.000 +0.75/-0.000 2.00 50.0 +0.030/-0.000 +0.75/-0.000 2.25 57.0 +0
17、.030/-0.000 +0.75/-0.000 2.50 65.0 +0.030/-0.000 +0.75/-0.000 2.75 70.0 +0.030/-0.000 +0.75/-0.000 3.00 75.0 +0.030/-0.000 +0.75/-0.000 3.25 82.0 +0.030/-0.000 +0.75/-0.000 3.50 90.0 +0.030/-0.000 +0.75/-0.000 4.00 100.0 +0.030/-0.000 +0.75/-0.000 5.00 125.0 +0.030/-0.000 +0.75/-0.000 Bore ovality t
18、olerance will not exceed the total applicable ID tolerance Copyright Navistar International Corporation Provided by IHS under license with INTERNNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NUMBER: TMS-1050 TITLE Flexible Steel Hose REVISION: 0904 This document
19、is restricted and may not be sent outside Navistar, Inc. or reproduced without permission from Corporate Technical Standards. Suppliers are required to assume all patent liability. 2008 by Navistar, Inc. APRIL 2009 Page 3 of 7 Outer Diameter - Type II only OD Tolerance inch mm Inch mm 2.50 65 +0.020
20、/-0.010 +0.50/-0.25 2.75 70 +0.020/-0.010 +0.50/-0.25 3.0 75 +0.020/-0.010 +0.50/-0.25 3.5 90 +0.020/-0.010 +0.50/-0.25 4.0 100 +0.020/-0.010 +0.50/-0.25 5.0 125 +0.020/-0.010 +0.50/-0.25 Outer diameter ovality tolerance will not exceed the total applicable OD tolerance. 4.5 Length - applies to both
21、 Type I and Type II Specific requirements for cut lengths of hose for each part number are shown on the Engineering Tabulation drawings. Tolerance for compressed (solid) length is +0.050/-0.000 inch (+1.25/-0.00 mm). Cut lengths of hose shall be furnished in an extended length which is approximately
22、 midway between the compressed length and full extension (see engineering tabulations for specific requirements); tolerance for furnished length is +0.25/-0.00 inch (+6.5/-0.00 mm). 4.6 Straightness - applies to both Type I and Type II Cut lengths of hose shall be straight within 0.25 inch/foot (20
23、mm/m). 4.7 Installation Install hose in the 10 %, partially extended position, normally one-half of the total extension. 4.8 Bending Radius The minimum inside bend radius for flex pipe connections is shown below: Note: Installation of the flex pipe in a bent condition may significantly reduce the se
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- INTERNTMS10502009FLEXIBLESTEELHOSE 柔性 软管 PDF