GMW GMW14652-2011 Interior Trim Compression Molded and Moldable Composite Materials Issue 3 English《内部装饰压缩模塑和可模塑复合材料 第3次出版(英文版本)》.pdf
《GMW GMW14652-2011 Interior Trim Compression Molded and Moldable Composite Materials Issue 3 English《内部装饰压缩模塑和可模塑复合材料 第3次出版(英文版本)》.pdf》由会员分享,可在线阅读,更多相关《GMW GMW14652-2011 Interior Trim Compression Molded and Moldable Composite Materials Issue 3 English《内部装饰压缩模塑和可模塑复合材料 第3次出版(英文版本)》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、 WORLDWIDE ENGINEERING STANDARDS Material Specification GMW14652 Interior Trim Compression Molded and Moldable Composite Materials Copyright 2011 General Motors Company All Rights Reserved October 2011 Originating Department: North American Engineering Standards Page 1 of 7 1 Scope 1.1 Material Desc
2、ription. Materials approved to this specification include compression molded and moldable composite materials. 1.1.1 Phenolic resin based materials are not allowed for interior applications. 1.1.2 Injection molded thermoplastic materials are not covered by this specification. Materials intended for
3、this specification are normally processed by compression thermoforming. 1.1.3 Materials intended to be used in substrate applications must also meet the assembly performance requirements per GMW14444 as assembled. 1.2 Symbols. Not applicable. 1.3 Typical Applications. Typical applications include in
4、terior trim substrates with textile covering for example rear window trim, rear compartment side trim, deck lid trim, load floors, etc. 1.4 Remarks. Not applicable. 2 References Note: Only the latest approved standards are applicable unless otherwise specified. 2.1 External Standards/Specifications.
5、 ISO 178 ISO 17025 ISO 5084 2.2 GM Standards/Specifications. GMW3059 GMW3235 GMW3116 GMW3259 GMW3182 GMW14444 GMW3205 GMW14777 GMW3221 GMW16190 GMW3232 2.3 Additional References. TMC003 Material Safety Data Sheet guidance documents (available at ). 3 Requirements 3.1 General Requirements. 3.1.1 Test
6、 Data. Lab testing is to be performed by a laboratory that conforms to ISO 17025 and is acceptable to the customer (GM). Test reports must conform to ISO 17025 sections 5.10.2 and 5.10.3. 3.1.2 Standard Conditions (GMW3221). All test specimens shall be conditioned to GMW3221, Code A, unless the test
7、 method indicates that standard conditioning is not required. Condition the specimens for a minimum of 24 h prior to testing or until moisture equilibrium is reached. If specimens are tested outside the conditioned environment, they shall be tested within ten minutes of removal. 3.1.3 Sampling and T
8、est Specimen Preparation. For directional properties, samples shall be reported with machine direction and against machine direction. All test specimens shall be taken from the area beyond the initial 2 m of production and at least 50 mm from either selvage edge. Prepare test specimens as required i
9、n the respective test method. 3.1.4 Data Reporting. If all individual readings of a specific test meet or exceed the specified requirements, report the average. Unless otherwise stated, any individual reading outside the specified limit does not meet the requirement. Report all individual test resul
10、ts that do not meet the requirements. All required information shall be reported on the appropriate test data reporting forms (Appendix A). Any additional test requirements shall be provided to GM upon request (i.e., high speed stress strain and compression curves for computer simulation). 3.2 Const
11、ruction Requirements for Substrate. All testing shall be conducted on a formed part at ideal thickness for physical properties without facing material. Report values in Appendix A. 3.2.1 Weight (GMW3182). Test three specimens and report the average in g/m2 for the substrate weight. Acceptable produc
12、tion tolerances shall be 10% the specified nominal substrate weight. Any deviation must be agreed to by appropriate GM engineer. Refer to the construction sheet for weight specifications. 3.2.2 Thickness (ISO 5084). Report the average for three specimens without facing material, in Provided by IHSNo
13、t for ResaleNo reproduction or networking permitted without license from IHS-,-,-GM WORLDWIDE ENGINEERING STANDARDS GMW14652 Copyright 2011 General Motors Company All Rights Reserved October 2011 Page 2 of 7 millimeters to the nearest 0.1 mm. Use a 2.0 N load and a 50.5 mm diameter presser foot to a
14、chieve a pressure of 1.0 kPa. All readings should be taken after the presser foot has been in contact with the material for at least 5 s. Refer to the construction sheet for thickness. 3.2.3 Flexural Properties (ISO 178). Test five specimens in the machine and against machine direction for nominal t
15、hickness without facing material. Test speed 50 mm/minutes, 100 mm span, 5 mm support radius, and sample size 75 mm by 200 mm. Report flexural strength (maximum force over first 25 mm of deflection), flexural stiffness (initial slope of flexural curve), and flexural toughness (percent retention of m
16、aximum force compared to force at 25 mm) averages on construction sheet. Submit flexural stress strain curve. 3.2.4 Fogging (GMW3235, Method B). Report the average of three specimens. The weight change of the used aluminum foil shall be no greater than 1.5 mg. The bath temperature shall be 90 C. 3.2
17、.5 Flammability (GMW3232). Test as received and after aging. Report Bmax and Bstat requirement must be less than 100 mm/minute. 3.2.6 Odor (GMW3205). Report both wet and dry results Coding A and B, Rating of 6 minimum. Use a ratio of specimen size to container size of 1 to 50. 3.2.7 Mildew (GMW3259)
18、. Required only if natural fibers are present in the construction. There shall be no visible growth or odor of mildew. 3.2.8 Cantilever Sag (GMW16190). Test three specimens in machine direction and three specimens against machine direction. Specimen size is 75 mm by 300 mm. Secure fixed side in flat
19、 plate and tighten with no more than 25 mm of length secured. Measure the initial height of sample at the end of sample opposite fixed end. Measure the height of sample at the end after minimum of 24 h at 85 C. Report change in height after 24 h at 85 C. Each sample should be individually supported.
20、 3.2.9 Moisture Content (GMW14777). Substrates that are susceptible to moisture should be tested to 30 minutes (Code A). Moisture content must be 8% by mass. Water absorption must be 40% by mass. Thickness swell must be 40% by mass. 3.3 Color Requirements. As defined by requirements of facing materi
21、al specification. 3.4 Part Requirements. Requirements of GMW14444 plus below requirements on formed parts with facing material. Additionally, any component testing, such as knee load testing, shall be evaluated prior to approval. 3.4.1 Weight (GMW3182). Test three specimens and report the average. R
22、eport the average in g/m2 for the substrate weight. Acceptable production tolerances shall be 10%, the specified nominal substrate weight. Any deviation must be agreed to by appropriate GM Engineer. Refer to the construction sheet for weight specifications. 3.4.2 Thickness (ISO 5084). Report the ave
23、rage for three specimens with facing material, in millimeters to the nearest 0.1 mm. Use a 2.0 N load and a 50.5 mm diameter presser foot to achieve a pressure of 1.0 kPa. All readings should be taken after the presser foot has been in contact with the material for at least 5 s. Refer to the constru
24、ction sheet for thickness. 3.4.3 Flexural Properties (ISO 178). Test five specimens in the machine and against machine direction for nominal thickness with facing material. Test speed 50 mm/minutes, 100 mm span, 5 mm support radius, and sample size 75 mm by 200 mm. Report flexural strength (maximum
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便