GMKOREA EDS-T-5702-2008 METHOD OF TEST FOR INSULATION CABLE.pdf
《GMKOREA EDS-T-5702-2008 METHOD OF TEST FOR INSULATION CABLE.pdf》由会员分享,可在线阅读,更多相关《GMKOREA EDS-T-5702-2008 METHOD OF TEST FOR INSULATION CABLE.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、GM DAEWOO Auto & Technology EDS Engineering, GM DAEWOO Auto & Technology Standards METHOD OF TEST FOR INSULATION CABLE Do Not Use on New Programs. Being Replaced by GMW3172 EDS-T-5702 ISSUED DATE: 1991. 08. 20 REVISED DATE: 2008. 10. 21 VERSION: 3 (Superceded) EDS-T-5702METHOD OF TEST FOR INSULATION
2、 CABLE PAGE: 1/7 ISSUED DATE: 1991. 08. 20 REVISED DATE: 2008. 10. 21 VERSION: 3 GM DAEWOO Auto & Technology Note: This standard may be applied only for current project (incl. T255 Program). It is Superceded for all future projects and replaced by GMW3172. 1. PURPOSE The standard aims at performing
3、an accurate test by specifying the test method, condition and standard for insulated wire used for automobile. 2. SCOPE This standard specifies all the unit insulated cable used by GMDAT excluding the high frequency and high tension wire. (However, when there are separate standards or drawings of a
4、higher order, they shall prevail.) 3. DEFINITION 3.1. Insulated wire: The insulated wire refers to a connector to connect circuits or devices to each other electrically. 3.2. Native copper: Native copper refers to pure copper. 3.3. Bronze: Bronze refers to the alloy of tin and copper. 4. PREPARATION
5、 4.1. Unless otherwise specified in the drawing, prepare an insulated cable less than 2M in length. 4.2. Unless otherwise specified in the test procedure, perform the test at (+235). 4.3. Prepare the measuring instruments and equipment for dimension measurement (Refer to the standard). 5. REGULATION
6、 AND STANDARD FOR UNIT INSULATED WIRE Conform to Table 1. However, when it is specified in the drawing specially, the drawing specification prevails. Table 1 Resistance value of conductor Conductor cross-section Number of wires Wire dia. X Conductor dia. X Native copper m /M Bronze m /M Thickness of
7、 cover X Whole dia. of insulated cable X 0.05 7 0.11 0.4 349 356 0.3 1.0 0.22 7 0.21 0.7 84.8 86.5 0.3 1.3 0.38 12 0.21 0.9 54.4 55.5 0.3 1.5 0.5 16 0.21 1.1 37.1 38.2 0.6 2.3 0.75 24 0.21 1.3 24.7 25.4 0.6 2.5 1.0 32 0.21 1.5 18.5 19.1 0.6 2.7 1.5 30 0.26 1.8 12.7 13.0 0.6 3.0 2.5 50 0.26 2.2 7.60
8、7.82 0.7 3.6 4.0 56 0.31 2.8 4.71 4.85 0.8 4.4 EDS-T-5702METHOD OF TEST FOR INSULATION CABLE PAGE: 2/7 ISSUED DATE: 1991. 08. 20 REVISED DATE: 2008. 10. 21 VERSION: 3 GM DAEWOO Auto & Technology Continued Resistance value of conductor Conductor cross-section Number of wires Wire dia. X Conductor dia
9、. X Native copper m /M Bronze m /M Thickness of cover X Whole dia. of insulated cable X 6.0 84 0.31 3.4 3.14 3.23 0.8 5.0 10.0 80 0.41 4.5 1.82 1.85 1.0 6.5 16.0 126 0.41 6.3 1.16 1.18 1.0 8.3 6. TEST CONDITION AND SPECIFIED VALUE Conform to Table 2. However, when it is specified in the drawing spec
10、ially, the drawing specification prevails. Table 2 Test item Grade Classification A B C 0.5 max. 3 q (Effective value) 3 q (Effective value) 3 q (Effective value) Insulation test 0.5 min. 5 q (Effective value) 5 q (Effective value) 5 q (Effective value) Test voltage 1 q (Effective value) 1 q (Effect
11、ive value) 1 q (Effective value) 0.5 max. Breakdown voltage 3 q (Effective value) 3 q (Effective value) 3 q (Effective value) Test voltage 1 q (Effective value) 1 q (Effective value) 1 q (Effective value) Breakdown voltage when applying voltage for 30 min. 0.5 min. Breakdown voltage 5 q (Effective v
12、alue) 5 q (Effective value) 5 q (Effective value) Test temperature (70 2) (70 2) (70 2) Insulation resistance Resistance capacity 103X min. 103X min. 103X min. High temperature/ High tension test Test temperature (70 2) (105 2) (120 2) High temperature exposure test Test temperature (105 2) (120 2)
13、(155 2) Test temperature (150 2) (150 2) - Thermal deformation test Change rate Within 4% Within 4% Flame trans. time 30 seconds 30 seconds 15 seconds Flame transmission resistance test Extinguishing time 30 seconds 30 seconds 70 seconds Low temperature exposure test Test temperature in winding test
14、 (-25 3) (-25 3) (-25 3) 0.5 to 1.0 0.5 b 0.5 b 0.5 b Wire holding strength test 1.0 to 2.5 1.25 b 1.25 b 1.25 b Test temperature (90 2) (90 2) (90 2) Oil resistance test Change rate 4% 4% Within 20% Fuel resistance test Change rate 6% 6% Within 30% EDS-T-5702METHOD OF TEST FOR INSULATION CABLE PAGE
15、: 3/7 ISSUED DATE: 1991. 08. 20 REVISED DATE: 2008. 10. 21 VERSION: 3 GM DAEWOO Auto & Technology 7. TEST METHOD 7.1. Insulation test 7.1.1. The cable shall not exhibit insulation breakdown when applying a specified AC voltage. 7.1.2. The frequency of the AC voltage shall be 50 Hz or 60 Hz. 7.1.3. A
16、pplying time of the AC voltage shall be one sec. 7.2. Breakdown voltage when applying the voltage for 30 min 7.2.1. Prepare a test sample of 1200mm. 7.2.2. When applying the specified voltage for 30 minutes as specified in Fig. 1 after leaving the test sample in 3% salt solution at room temperature
17、(235) for 4 hours, the test sample shall not exhibit insulation breakdown. 7.2.3. When raising the voltage to the specified voltage of 500V/sec after applying the voltage for 30 minutes, the test sample shall not exhibit insulation breakdown. 7.3. Insulation resistance 7.3.1. Prepare the a sample of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMKOREAEDST57022008METHODOFTESTFORINSULATIONCABLEPDF

链接地址:http://www.mydoc123.com/p-757181.html