1、GM DAEWOO Auto & Technology EDS Engineering, GM DAEWOO Auto & Technology Standards THE TEST OF ELECTRIC COMPONENTS FOR INTELLIGENT SWITCHING UNIT Do Not Use on New Programs. Being Replaced by GMW3172 EDS-T-5428 ISSUED DATE: 1998. 07. 03 REVISED DATE: 2008. 10. 21 VERSION: 4 (Superceded) THE TEST OF
2、ELECTRIC COMPONENTS FOR INTELLIGENT SWITCHING UNIT EDS-T-5428PAGE: 1/10 ISSUED DATE: 1998. 07. 03 REVISED DATE: 2008. 10. 21 VERSION: 4 GM DAEWOO Auto & Technology Note: This standard may be applied only for current project (incl. T255 Program). It is Superceded for all future projects and replaced
3、by GMW3172. 1. PURPOSE This standard aims at correctly evaluating performance of components of the intelligent switching unit used for passenger cars manufactured by GM DAEWOO Auto & Technology Company (hereinafter referred to as the “GMDAT“). 2. SCOPE This standard applies to components of the inte
4、lligent switching unit applied to the automobiles 3. DEFINITION OF TERMS 3.1. Intelligent switching unit It receives inputs of various function switches to have the micro-computer automatically control such output loads as the motor, lamp and warning buzzer according to the pre-determined program. 3
5、.2. RKE (remote keyless entry) receiver It receives the high frequency from the radio transmitter to perform door opening/closing specified in drawing. 3.3. Immobilizer It has ECM cut off engine starting when it is tried with means other than the peculiar key for the vehicle. 4. TEST CONDITIONS 4.1.
6、 Standard test condition Test voltage used for module performance and durability test, it is the voltage specified in drawings or test specifications. Unless specified otherwise, it is 12.0 1V for RKE receiver and immobilizer functions and 14.0 0.2V for other functions. 4.2. Standard test condition
7、Unless specified otherwise, test is conducted under the normal temperature and humidity condition specified in KS A006 (Test Place Standard Condition). 4.3. Quantity of samples At least 15 DVP and PVP samples shall be provided for test in principle. 5. TEST EQUIPMENT 5.1. Generals THE TEST OF ELECTR
8、IC COMPONENTS FOR INTELLIGENT SWITCHING UNIT EDS-T-5428PAGE: 2/10 ISSUED DATE: 1998. 07. 03 REVISED DATE: 2008. 10. 21 VERSION: 4 GM DAEWOO Auto & Technology Measuring instruments used for test shall basically be calibrated by the national calibration institute and within the effective calibration p
9、eriod. 5.2. Thermostatic chamber Capable of maintaining temperature from -40 to +90, it shall have a minimum capacity of 100 liter. It shall also be able to control relative humidity at each temperature up to 95% with permissible error not exceeding +2 per temperature. 5.3. Vibration tester It shall
10、 be capable of performing test to KS R 1034 (Automobile Components Vibration Test method). 5.4. Control device for durability test It shall be capable of automatically supply and cut-off voltage for unit operation, detect defects and record progress time and no. of cycles in durability test. 6. TEST
11、 PROCEDURES 6.1. Appearance test 6.1.1. Visual test (1) Conduct visual inspection. (2) When observed visually, the unit shall show no sign of harmful flaws, cracks, or other defects that may adversely affect the performance. 6.1.2. Dimension test Specified samples based on KS B 5203 (Venire calipers
12、) shall be used. Samples shall meet material requirements of the design specifications and dimensional requirements in drawings. 6.2. Performance 6.2.1. Basic performance test At the standard test voltage, operating characteristics of basic functions specified in DWG shall be within the allowable ra
13、nge. 6.2.2. Operating Temperature & voltage (1) At supply operating voltage of 9 16 V, operating temperature -40+85,operating characteristics of basic functions specified in DWG shall be within the allowable range. (2) Unless specified otherwise, measuring shall be conducted at 3 or more test voltag
14、es (9V, standard voltage, 16V). 6.2.3. Leakage current (1) Unless specified otherwise, it shall be measured at the battery power line with standard test voltage of 12.6 0.1V. THE TEST OF ELECTRIC COMPONENTS FOR INTELLIGENT SWITCHING UNIT EDS-T-5428PAGE: 3/10 ISSUED DATE: 1998. 07. 03 REVISED DATE: 2
15、008. 10. 21 VERSION: 4 GM DAEWOO Auto & Technology (2) Test shall be conducted with the ignition power line OFF. (3) The measured current shall not exceed the allowable range specified in DWG. 6.2.4. Current consumption (1) It is conducted with the standard voltage supplied. (2) Measurement shall be
16、 made separately for ignition power cables and battery power cables. (3) The measured current shall not exceed the allowable range specified in DWG. 6.2.5. RF (radio frequency) reception sensitivity of remote key function Test items consist of reception sensitivity, reception bandwidth and reception
17、 selection degree and test shall be conducted to EDS-T-5427. The test results shall not exceed the allowable range specified in DWG. 6.3. Electric resistance test 6.3.1. Source voltage change test (1) This test is to confirm if the unit operates normally according to the varying source voltage at en
18、gine starting. (2) After the following test voltage cycle is applied to the battery and ignition source terminals with the sample constructed to the design specifications, basic performance requirements in 6.2.1 shall be met. 1) Test temperature: Normal temperature and normal humidity (standard test
19、 temperature) 2) Test voltage: 6(V) 12(V) 3) Total test cycles: 10 cycles 4) 1 test cycle 6.3.2. Source voltage chattering test (1) This test is to confirm if the unit operates normally according to the varying source voltage at engine starting. (2) After the following test voltage cycle is applied
20、10 cycles respectively to the battery and ignition source terminals for each source voltage chattering type with the sample constructed to the design specifications, basic performance requirements in 6.2.1 shall be met 1) Test temperature: Normal temperature and normal humidity (standard test temper
21、ature) 2) Test voltage: 6V 14V (B TYPE: 0V 14V) THE TEST OF ELECTRIC COMPONENTS FOR INTELLIGENT SWITCHING UNIT EDS-T-5428PAGE: 4/10 ISSUED DATE: 1998. 07. 03 REVISED DATE: 2008. 10. 21 VERSION: 4 GM DAEWOO Auto & Technology 3) Type A source voltage chattering cycle (1 cycle) 4) Type B source voltage
22、 chattering cycle (1 cycle) 6.3.3. Over voltage/reverse-voltage (1) This test is conducted to check if the unit inside circuit is protected from over voltage and reverse voltage that may occur at battery discharge. (2) At test, the unit shall be wired in the vehicle condition. For the system furnish
23、ed with an inside protection circuit, the inside protection circuit (fuse) shall be inserted before the unit is operated. (3) When power to the sample is cut off by the action of the inside protection circuit (fuse), immediately replace the fuse with a new one of the same type. (4) After the followi
24、ng abnormal voltage is applied, basic performance requirements in 6.2.1 shall be met. Over voltage A Test voltage: 180.2V Test time: 60 minutes Test temperature: Normal temperature and normal humidity (standard test temperature) Over voltage B Test voltage: 240.2V Test time: 1 minute Test temperatur
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GMKOREAEDST54282008THETESTOFELECTRICCOMPONENTSFORINTELLIGENTSWITCHINGUNITPDF

链接地址:http://www.mydoc123.com/p-757154.html