《GME 13003-1-2006 Passenger Car - Heating-Ventilation and Air Conditioning Part 1 HVAC-Modul General Requirements (English German This specification may be applied only for current up.pdf》由会员分享,可在线阅读,更多相关《GME 13003-1-2006 Passenger Car - Heating-Ventilation and Air Conditioning Part 1 HVAC-Modul General Requirements (English German This specification may be applied only for current up.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、GeneralSpecificationHVAC & PT Cooling GME 13003-1Passenger Car - Heating - Ventila-tion and Air ConditioningFahrzeug- Heizung-BelftungundKlimatisierungPart 1: HVAC-Modul General RequirementsNote: This specification may be applied only forcurrent projects incl. Global Epsilon (37#). Itis Superceded f
2、or all future projects and replacedby GMW14780.Teil 1: HVAC-Modul Allgemeine AnforderungenHinweis: Diese Spezifikation darf nurnoch fr laufende Projekte einschlielichGlobal Epsilon (37#) angewendet werdenund ist fr alle zuknftigen Projekte ungltig undersetzt durch GMW14780.1 Introduction 1 Einfhrung
3、1.1 Scope. Heating and air conditioning for the com-plete vehicle range.1.1 Anwendungsbereich. Heizungen und Klimaan-lagen fr die komplette Fahrzeugpalette.1.2 Mission / Theme. This specification defines thegeneral requirements, test conditions and test meth-odsforfunction,materialandstaticloadtests
4、forheat-ing and air conditioning for automotive applications.1.2 Aufgabe / Thema. Diese Spezifikation legt dieAllgemeinen Anforderungen, Prfbedingungen undPrfverfahren fr Funktions-, Werkstoff- und Bela-stungsprfungen an Heizungen und Klimaanlagenfest.1.3 Classification. General requirements andrequ
5、irements for single components are defined inthe following parts to this specification.1.3 Einteilung. Allgemeine Anforderungen undAnforderungen an Einzelkomponenten sind in dennachfolgend aufgefhrten Teilen zu dieser Vorschriftfestgelegt:Part 1: General Requirements. Teil 1: Allgemeine Anforderunge
6、n.Part 2: Water Separation. Teil 2: Wasserseparation.Part 3: Pollen Filter. Teil 3: Reinluftfilter.Part 4: Blower and Recirculating Air Housing. Teil 4: Geblse und Umluftgehuse.Part 5: Heating Unit, Air Conditioning Unit (draw-ing no. 90240367 (Note 1), 9287284 (Note1).)Teil 5: Heizkammer, Klimagert
7、 (Zeichnung Nr.90240367 (Note 1), 9287284 (Note 1).Part 6: Evaporator. Teil 6: Verdampfer.Part 7: Heater Core (GMI L-13D-1 (Note 1). Teil 7: Wrmetauscher (GMI L-13D-1 (Note 1).Part 8: Air Ducts. Teil 8: Luftfhrungsschluche.Part 9: Outlets. Teil 9: Dsen.Part 11: Refrigerant Lines. Teil 11: Kltemittel
8、leitungen.Part 12: Compressor. Teil 12: Verdichter.Part 13: Condenser. Teil 13: Kondensator.Part 16: Electronic Temperature Control. Teil 16: Elektronische Temperaturregelung.Note 1: Currently still valid, but will be reworked. Note 1: Derzeit noch gltig, wird aber berarbeitet. Copyright 2006 Genera
9、l Motors Corporation All Rights ReservedPublication Department: GME Specification CenterNovember 2006 - Issue No. 4 Page 1 of 9PRD045 - VPRE ST 1 10/03GME 13003-1 GM EUROPE ENGINEERING STANDARDSPart 17: Air Exhaust Louver with Non-ReturnThrottle.Teil 17: Entlftungsvorrichtungen mit Rckstrom-sperre.P
10、art 18: Hybrid Filter. Teil 18: Hybridfilter.Part 21: AdditionalandParking Heater (Fuel Heat-ing).Teil 21: Zusatz- und Standheizung (Brennstoffbe-triebene Heizung).Note: Nothing in the specification supersedes appli-cable laws and regulations.Hinweis: Die Vorschrift darf keine anzuwendendenGesetze u
11、nd Regelungen auer Kraft setzen.Note: In the event of a conflict between the GermanandtheEnglishlanguage,the Germanlanguageshalltake precedence.Hinweis: Im Falle von Unstimmigkeiten zwischendem deutschen und dem englischen Text ist derdeutsche Text ausschlaggebend.2 References 2 ReferenzenNote: Only
12、 the latest approved standards are appli-cable unless otherwise specified.Hinweis: Wenn nicht anders angegeben, ist jeweilsdieneuesteFassungder angegebenen Referenz gl-tig.2.1 External Standards/Specifications. 2.1 Externe Normen/Vorschriften.ECE-R21 EN 10204 FMVSS 302 IEC 60068-2-142.2 GM Group Sta
13、ndards/Specifications. 2.2 GM Gruppe Normen/Vorschriften.902403679287284B 040 1065GME 60202GME 60276GME 60326GMI 60206GMI L-13D-1GMW3059GMW3091GMW3097GMW3103GMW3172GMW3191GMW3232ON 202ON 1397QT 1265952.3 Additional References. VDA 260 2.3 Zustzliche Referenzen. VDA 2603 Test Preparation and Evaluati
14、on 3 Prfungsvorbereitung undAuswertung3.1 Resources. 3.1 Gerte und Einrichtungen.3.1.1 Calibration. The test facilities and equipmentshall be in good working order and shall have a validcalibration label.3.1.1 Kalibrierung. Alle Prfungseinrichtungen und-ausrstungen mssen funktionsfhig sein und eineg
15、ltige Kalibrierplakette haben.3.1.2 Alternatives. Alternative test facilities andequipment may also be used. However, all measur-ing variables as specified in this specification shallbe determined correctly with respect to its physicaldefinition.3.1.2 Alternativen. EsknnenauchalternativePrf-einricht
16、ungen und -ausrstungen verwendet werden.Alle Messvariablen, wie sie in dieser Vorschrift ange-geben werden, mssen jedoch in Bezug auf ihre phy-sikalische Definition korrekt festgelegt werden.3.1.3 Facilities. 3.1.3 Einrichtung.3.1.3.1 According to the stated standards, test meth-ods, test specificat
17、ions, etc.3.1.3.1 Entsprechend den angegebenen Normen,Prfverfahren, Prfvorschriften, usw.3.1.3.2 Recirculating air cabinet: 3.1.3.2 Umluft-Temperaturschrank: Copyright 2006 General Motors Corporation All Rights ReservedPage 2 of 9 Issue No. 4 - November 2006PRD045 - VPRE ST G 10/03GM EUROPE ENGINEER
18、ING STANDARDS GME 13003-1Temperature range: (-20.+90) C Temperaturbereich: (-20.+90) CPermissible temperature deviations: 3 C Zulssige Temperaturabweichung: 3 CUsable interior space w x h x d:(1.0 x 1.0 x 1.0) m min.Nutzbarer Innenraum B x H x T:(1.0 x 1.0 x 1.0) m min.3.1.3.3 Environmental chamber
19、to test heating andair conditioning modules in high humidity environ-ments to GME 60202.3.1.3.3 Klimakammer zur Prfung der Heizkammernund Klimagerte auf Bestndigkeit gegen Kondens-wasser-Klimate nach GME 60202.Chamber dimensions w x h x d:(1.0 x 1.0 x 1.0) m min.Abmessungen des Prfraumes B x H x T:(
20、1.0 x 1.0 x 1.0) m min.3.1.4 Equipment. 3.1.4 Ausrstung.3.1.4.1 According to the stated standards, test meth-ods, test specifications, etc.3.1.4.1 Entsprechend den angegebenen Normen,Prfverfahren, Prfvorschriften, usw.3.1.4.2 Instruments and gauges for dimensionalchecks.3.1.4.2 Messgerte und Lehren
21、fr die malichenPrfungen.3.1.4.3 Air volume flow meter (0.3) l/s. 3.1.4.3 Luftdurchflussmesser (0.3) l/s.3.1.4.4 Suitable blower to produce the following rampressures:3.1.4.4 Ein geeignetes Geblse zum Aufbringen desStaudruckes mit folgenden Kennwerten: 600 Pa at a flow rate of 100 l/s 600 Pa bei 100
22、l/s Luftdurchsatz 400 Pa at a flow rate of 200 l/s 400 Pa bei 200 l/s Luftdurchsatz3.2 TestSamples. Unlessotherwisespecifiedforini-tial sample approval and validation test to this spec-ification at least 5 components of the same type arerequired. The test samples shall be supplied with atest certifi
23、cate to EN 10204.3.2 Prfteile. Falls nicht anders angegeben, sindzur Erstbemusterung und Freigabeprfung nach die-ser Vorschrift mindestens 5 Einzelkomponenten glei-chen Typserforderlich. DiePrfmustersindmiteinemWerksprfzeugnis nach EN 10204 anzuliefern.The delivery of further samples of the same typ
24、e maybe agreed.Die Lieferung weiterer Muster derselben Ausfhrungkann vereinbart werden.3.3 Conditioning. Unless otherwise specified in therelevant tests, the tests shall be performed in the asreceived condition at (+23 5) C.3.3 Probenvorbehandlung. Falls bei den einzelnenPrfungen nicht anders angege
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- GME1300312006PASSENGERCARHEATINGVENTILATIONANDAIRCONDITIONINGPART1HVACMODULGENERALREQUIREMENTSENGLISHGERMANTHISSPECIFICATIONMAYBEAPPLIEDONLYFORCURRENTUPPDF

链接地址:http://www.mydoc123.com/p-754865.html