FORD WTX-1994 GROUNDING WELDING TRANSFORMERS - REACTIR METHOD《接地线焊接变压器 Reactir法》.pdf
《FORD WTX-1994 GROUNDING WELDING TRANSFORMERS - REACTIR METHOD《接地线焊接变压器 Reactir法》.pdf》由会员分享,可在线阅读,更多相关《FORD WTX-1994 GROUNDING WELDING TRANSFORMERS - REACTIR METHOD《接地线焊接变压器 Reactir法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、 Manufacturing StandardsFord Motor Company199406 GROUNDING WELDING TRANSFORMERS - WTXREACTOR METHODEngineering Standards the| insulation shall conform to Ford Electrical Standard EX1, Section| 11. The leads shall be insulated from the core and shall be| connected to the reactor, and clamped to the c
2、ase in such a manner| that they may be used as a carrying medium.5.3 | The reactor shall be provided with four mounting feet to permit| mounting on a base plate or welding transformer with four 5/16-18| screws on 85.7 x 85.7 mm(3-3/8 x 3-3/8 in), 85.7 x 111.1 mm (3-3/8 x| x 4-3/8 in), or 85.7 x 136.