FORD WSK-M4D754-A-2015 POLYAMIDE (PA) 6 HEAT STABILIZED 15 % GLASS FIBER REINFORCED MOLDING COMPOUND EXTERIOR TO BE USED WITH FORD WSS-M99P1111-A .pdf
《FORD WSK-M4D754-A-2015 POLYAMIDE (PA) 6 HEAT STABILIZED 15 % GLASS FIBER REINFORCED MOLDING COMPOUND EXTERIOR TO BE USED WITH FORD WSS-M99P1111-A .pdf》由会员分享,可在线阅读,更多相关《FORD WSK-M4D754-A-2015 POLYAMIDE (PA) 6 HEAT STABILIZED 15 % GLASS FIBER REINFORCED MOLDING COMPOUND EXTERIOR TO BE USED WITH FORD WSS-M99P1111-A .pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATIONMaterial Name Specification NumberDate Action Changes1990 04 02 EP00E01031534000 Released M. SiewertWP 3948-a Page 1 of 6 POLYAMIDE (PA) 6, HEAT STABILIZED, 15 % GLASS WSK-M4D754-AFIBER REINFORCED MOLDING COMPOUND, EXTERIOR1. SCOPEThe material defined by this speci
2、fication is a heat stabilized, UVstabilized glass fiber reinforced polyamide 6 molding compound for exterioruse.2. APPLICATIONThis specification was released originally for material used for exteriorfunctional automotive applications.NOTICE: This material absorbs and retains moisture. Part design an
3、dtolerances must accommodate changes in part dimensions and physicalproperties due to moisture absorption or loss in the service/assemblyenvironment.3. REQUIREMENT3.1 STATISTICAL PROCESSSuppliers must conform to the requirements of Ford Quality SystemStandard Q-101. A mutually acceptable Control Pla
4、n as describedtherein is required for material/source approval. Appropriatestatistical tools must be used to analyze process/product data sothat variation in the final product is continuously reduced.3.2 INFRARED SPECTROPHOTOMETRY AND/OR THERMAL ANALYSISFord Motor Company, at its option, may conduct
5、 infrared and/orthermal analysis of material/parts supplied to this specification.The IR spectra and thermograms established for initial approval shallconstitute the reference standard and shall be kept on file at thedesignated material laboratory. All samples shall produce IR spectraand thermograms
6、 that correspond to the reference standard when testedunder the same conditions.3.3 CONDITIONING AND TEST CONDITIONSAll test values indicated herein are based on material and specimenswith moisture content not exceeding 0.2 % (test according to ISO 960,Method B/ASTM D 789).NOT TO BE USED FOR NEW DES
7、IGN2015 N Status No replacement named D. Stark, NAENGINEERING MATERIAL SPECIFICATIONWSK-M4D754-AWP 3948-b Page 2 of 6 All test materials imme diately after processing have to be sealed incon tainers that are impermeable to water vapor. If the moisturecontent exceeds 0.2 %, condition the material for
8、 a minimum of 16 hat 40 - 50 EC at a reduced pressure below 133 Pa.Conduct tests in a controlled atmosphere of 23 +/- 2 EC and 50 +/-5 % relative humidity. Individual specimens shall not be removedfrom closed containers until immediately before testing.3.4 MOLDING COMPOUND3.4.1 Glass Fiber Content 1
9、2.5 - 17.5 %(ISO 3451/4, test temperature600 +/- 25 EC, test portion 1 g)3.4.2 Melt Temperature 215 - 225 EC(ISO 1218, Method B/ASTM D 789)3.5 MOLDED TEST SPECIMEN3.5.1 Preparation of Test SpecimensUnless otherwise specif ied all tests shall be carried out oninjection molded one-end gated test speci
10、mens.The following dimensions are required:A. 150 min x 10 x 4.0 +/- 0.2 mm (Tensile Bar, ISO 3167)B. 120 x 10 x 4.0 +/- 0.2 mmSpeci mens with shorter dimensions shall be cut from thecenter portion of the test specimen A and/or B. The specimensshall be prepared according to ISO 294. No annea ling al
11、lowed.3.5.2 Density 1.20 - 1.28 g/cm 3(ISO 1183, Method A/ASTM D 792, Method A1)3.5.3 Tensile Strength at Max Load, min 90 MPa(ISO R 527/ASTM D 638M,150 x 10 x 4.0 +/- 0.2 mmspecimen, 5 mm/minute test speed)3.5.4 Flexural Modulus, min 4.0 GPa(ISO 178/ASTM D 790M, Method I,Procedure A, 80 x 10 x 4.0
12、+/- 0.2 mmspecimen, 64 mm support span)3.5.5. Shear Modulus at 23 EC 1.11 - 1.86 GPa(ASTM D 4065, forced constant amplitude, fixed frequency of 1 Hz +/- 15 %, strain level below 1 %. Specimen approx. 60 x 10 x 4.0 +/- 0.2 mm cut from the center of specimen A. Specimen length between clamps 35-40 mm.
13、 Soak time at each temperature interval - 3 minutes minimum)ENGINEERING MATERIAL SPECIFICATIONWSK-M4D754-AWP 3948-b Page 3 of 6 Additionally, a Shear M odulus vs. Temperature curve shall beplott ed for - 50 to + 210 EC temperature range, at 5 ECminimum intervals. The plotted curve must be withintole
14、rance range shown on page 6.3.5.6 Impact Strength, Izod, min(ISO 180, Method A/ASTM D 256, Method A,63.5 x 10 x 4.0 +/- 0.2 mm specimen, 10 specimens for each test)3.5.6.1 At 23 +/- 2 EC 3 kJ/m 23.5.6.2 At - 40 +/- 2 EC 3 kJ/m 2The test specimens mu st be conditioned for minimumof 6 h at the above s
15、 pecified temperature prior toimpact test. Low temperature testing shall be donewithin the cold box, if not possible, test can beconducted outside, but within 5 s.3.5.7 Heat Deflection Temperature, min(ISO 75/ASTM D 648, 120 x 10 x 4.0 +/- 0.2 mm specimen)3.5.7.1 At 1.82 MPa 180 EC3.5.7.2 At 0.45 MP
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDWSKM4D754A2015POLYAMIDEPA6HEATSTABILIZED15GLASSFIBERREINFORCEDMOLDINGCOMPOUNDEXTERIORTOBEUSEDWITHFORDWSSM99P1111APDF

链接地址:http://www.mydoc123.com/p-750780.html