1、 Printed Copies are Uncontrolled Page 1 of 6 Standard Number: w-ES5 Issue Date: 20021210 Global Manufacturing Standards Rev: Cable Pull Emergency Stop Switches 1. GENERAL: 1.1 PURPOSE AND SCOPE To provide functional, performance, and installation requirements for Cable Operated Safety Switches (here
2、inafter switch) for industrial applications at Ford Motor Company (hereinafter the Company) operations located worldwide. Deviations from this Standard are permitted only upon written waiver by the requisitioning activity. 1.2 MANDATORY AND PREFERRED ITEMS Mandatory requirements of this Standard are
3、 characterized by the use of the word “shall“. Preferred items are characterized by the use of the word “should“. 1.3 DEFINITIONS 1.3.1 The normal operating condition of the switch is defined as “not-tripped“. In this condition, the normally open contacts are held closed and the normally closed cont
4、acts are held open. When the switch is “tripped“, these contacts shall change state simultaneously. 1.3.2 The terms: Cable, Rope, Pull Cord, and Tripwire are used interchangeably and are all understood to be a coated cable. This cable shall be a minimum of 3mm in diameter, 19-strand, aircraft type,
5、and corrosion resistant, steel cable with bright Red plastic coating. Maximum elongation shall not exceed 0.7mm/m.Printed Copies are Uncontrolled Page 2 of 6 Standard Number: w-ES5 Issue Date: 20021210 Global Manufacturing Standards Rev: 2. REFERENCE STANDARDS Whenever a specific Standard is referen
6、ced, it shall be the latest revision, unless otherwise specified. 2.1 Ford Motor Company Manufacturing Standard EX1 Supplemental Requirements to SAE HS-1738. 2.2 INDUSTRY STANDARDS: 2.2.1 UL 508, Industrial Control Equipment. 2.2.2 CSA C22.2-14-M91, Industrial Control Equipment. 2.2.3 BSI BS PD 5304
7、, Safe Use of Machinery. 2.2.4 SAE HS-1738, Electrical Standard for Industrial Machinery - Supplement to NFPA 79. 2.2.5 IEC 60204-1, Safety of Machinery, Electrical Equipment of Machines Part 1: General Requirements. 2.2.6 IEC 60068-2-6, Environmental Testing - Test Fc and Guidance: Vibration (Sinus
8、oidal). 2.2.7 IEC 60947-5-1, Low Voltage Switchgear and Controlgear for Control Circuit Devices and Switching Elements - Electromechanical Control Circuit Devices. 2.2.8 IEC EN 418, Safety of Machinery - Emergency Stop Equipment, Functional Aspects - Principles for Design. 2.2.9 IEC EN 50013, Low Vo
9、ltage Switchgear and Controlgear for Industrial use Terminal Marking and Distinctive Number for Particular Control Switches. 2.2.10 IEC EN 954-1, Safety of Machinery - Safety Related Parts of Control Systems - General Principles for Design. 2.2.11 DIN EN 616, Continuous Handling Equipment and System
10、s; Common Safety Requirements for Design, Manufacturing, Erection and Commissioning Stages. 2.2.12 OSHA 29-CFR-1910, Occupational Safety and Health Standards. 2.3 CONFORMANCE 2.3.1 All materials and components supplied to this Standard shall be equivalent in all respects to material upon which appro
11、val was originally granted. Any deviations from this Standard, Printed Copies are Uncontrolled Page 3 of 6 Standard Number: w-ES5 Issue Date: 20021210 Global Manufacturing Standards Rev: without written notice and subsequent review and re-approval by the Ford Global Manufacturing Standards - Electri
12、cal Technical Committee, will be sufficient cause for removal from the Ford Global Manufacturing Standards - Electrical Conforming Components List (E1-CCL). 2.3.2 All products submitted for evaluation shall be “off-the-shelf“ catalog types manufactured with normal production procedures and quality c
13、ontrol. Prototypes will not be considered. Suppliers shall submit an itemized Data Sheet, correspondingly numbered with this Standard, completely addressing their compliance with each provision. The Vice President of Engineering, or a higher officer of the Suppliers (Manufacturers) company shall sig
14、n this Data Sheet. Suppliers shall also submit copies of any and all test Agency certificates and associated letters and documentation, which cite the actual standards their products were tested to. Approvals shall be made based on conformance to this Standard as certified by the above Data Sheet, t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDWES52002CABLEPULLEMERGENCYSTOPSWITCHES 拉线 紧急 停车 开关 PDF

链接地址:http://www.mydoc123.com/p-748371.html