FORD FLTM BZ 105-05-2002 DETERMINATION OF SPECIATED PERMEATION RATES FOR POLYMERS《聚合物的特定渗透速度的测定》.pdf
《FORD FLTM BZ 105-05-2002 DETERMINATION OF SPECIATED PERMEATION RATES FOR POLYMERS《聚合物的特定渗透速度的测定》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BZ 105-05-2002 DETERMINATION OF SPECIATED PERMEATION RATES FOR POLYMERS《聚合物的特定渗透速度的测定》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BZ 105-05 Date Action Revisions 2002 05 06 Activated A. Olejnik, A. Reaume Printed copies are uncontrolled Page 1 of 5 Copyright 2002, Ford Global Technologies, Inc. DETERMINATION OF SPECIATED PERMEATION RATES FOR POLYMERS Application This method is used to determine the
2、 permeation rates of fuel components through a polymer film using the trap and desorption method. Using a gas chromatograph the collected vapors are speciated to provide permeation rates in grams/m2 day for each component. Principle The small scale solvent permeability test determines the permeation
3、 rate of a solvent mixture through a test film (e.g. polymer, elastomer or complex layers). The film is sandwiched between two chambers of a sealed small scale test cell. The test solvent/solution (in liquid or gas phase) is in contact with one side of the test film, and high purity nitrogen purge g
4、as is in contact with the opposite side of the film. The volatile organic compounds (VOC) permeating through the test film from the solvent side to the nitrogen purge side are trapped onto Trap and Desorption (T to 1000g), 8. Precision thickness gage, (e.g. Logitech CG-10 or equivalent), T or mixtur
5、es of these, or other liquid solvents. The solvents should be stored in a flammable solvent cabinet. 3. Certified VOC mixture in vapor gaseous Nitrogen matrix: isooctane (ISO), toluene (TOL), ethanol (ET), or mixtures of these, or others (Scott Certified Gases or equivalent). Procedure Test Apparatu
6、s: The test cells can be operated with either vapor or liquid contact with the film. The cell should be vented through a 1.8m long, 1/16“wide metal tubing which drops pressure to atmospheric, but minimizes diffusive loss of solvent vapors. The typical test is conducted with the solvent mixture in va
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBZ105052002DETERMINATIONOFSPECIATEDPERMEATIONRATESFORPOLYMERS 聚合物 特定 渗透 速度 测定 PDF

链接地址:http://www.mydoc123.com/p-747697.html