1、 FORD LABORATORY TEST METHOD BV 132-01 Date Action Revisions 2000 08 22 Revised Editorial no technical change A. Cockman 2000 05 18 Activated Y. Bankowski Printed copies are uncontrolled Page 1 of 6 Copyright 2000, Ford Global Technologies, Inc. DETERMINATION OF FERROMAGNETIC RESPONSIVENESS OF ADHES
2、IVES/SEALERS Application This procedure is used to determine the ferromagnetic responsiveness of an adhesive/sealer for the purposes of on -line mix ratio verification. The level of response is based on the amount of a taggant incorporated into an adhesive/sealer. The test is performed using a stand
3、ard eddy current non -destructive test instrument and coil under a set of standard conditions. Apparatus Required* Eddy Current Non-Destructive Test Instrument A non - destructive alloy and hardness -testing instrument that utilizes eddy current principles (Verimet N7700, or its equivalent). Eddy Co
4、il An eddy coil matched for use with the Eddy Current Non - Destructive Test Instrument. 40020M300 Transducer Transducer Cable The Transducer Cable is used to attach the Eddy Coil to the Non - Destructive Test Instrument. This cable should be 3 feet in length. Taggant Master Standards Two taggant ma
5、ster standards are used to verify performance and calibration of t he Eddy Coil and Non - Destructive Test Instrument. The taggant master standards required are 95% and 67%. *Source: K.J. Law Engineers, Inc. 42300 W. Nine Mile Road Novi, MI 48375 - 4103 Telephone: (248) 347 - 3300 Toll Free: (800) 5
6、21 - 5245 Fax: (24 8) 347 - 3345 Web Site: FORD LABORATORY TEST METHOD BV 132-01 Page 2 of 6 Copyright 2000, Ford Global Technologies, Inc. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/ - 2 C and 50 +/ - 5% re
7、lative humidity for a minimum of 24 hours prior to testing and tested under the same conditions, unless otherwise specified. All samples to be tested need to be contained in mixing nozzles from which the internal mix element has been removed. The outer diameter should be 16.764 +/ - 0.254 mm; the in
8、ner diameter should be 12.624 +/ - 0.038 mm; the nozzle should be at least 115 mm long. Fill the mix nozzle with adhesive/sealant per Test Specimen Preparation. Test Specimen Preparation Apparatus Required Sample Holders Mixing Nozzles without the internal mix elem ent will be used as sample holders
9、 for prepared standards and test specimens. The outer diameter should be 16.764 +/ - 0.254 mm (0.660 +/ - 0.010 in); the inner diameter should be 12.624 +/ - 0.038 mm (0.497 +/ - 0.0015 in). The mix nozzle will be cut to 115 mm, filled with material, and sealed for testing. Source: TAH Industries, I
10、nc., or other mixing nozzle supplier TAH Industries, Inc. 107 N Gold Drive Trenton, NJ 08691 Telephone: (609) 259 - 9222 Fax: (609) 259 - 0957 Web Site: Air-Assisted Caulking Gun, or Similar Device The caulking gun will be used to prepare standards and test specimens. Preparing Standards and Test S
11、pecimens Remove mixing element from mix nozzle and cut the mix nozzle so that the length is at least 115 m m. Using an air -assisted caulking gun or similar device, inject the sample into the mix nozzle. Ensure there are no voids or entrapped air. Seal the nozzle at both ends using masking tape or s
12、imilar. Note: When these test specimens are measured, they should be placed in the eddy current coil so that they are centered along the long axis (see Figure 1). FORD LABORATORY TEST METHOD BV 132-01 Page 3 of 6 Copyright 2000, Ford Global Technologies, Inc. Procedure 1. Settings for Operation of N
13、on-Destructive Test Instrument: (This step is to be performed initially, before any samples are tested) a. Connect the coil to the Non - Destructive Test Instrument via a transducer cable. b. Turn POWER on, and allow a 20 - minute warm - up period. c. Place the Master Standard in the eddy coil. Ensu
14、re that at least 25mm of the standard is protruding from eit her end of the coil (see Figure 1). Confirm the reading displayed on the Non - Destructive Test Instrument corresponds to the taggant level of the Master Standard. Note: Either Master Standard (95% or 67%) may be used. If you are measuring
15、 unmixed materia l, use the 95% Master Standard; if you are working with mixed material, the 67% Master Standard may be used. d. If necessary, adjust the readout display on the instrument to match the level of the Master Standard. Refer to the Appendix and Manufacturer s manual for specific instruct
16、ions on adjusting the readout displayed. e. The instrument is now ready to measure the ferromagnetic responsiveness of the prepared samples. f. Confirm the Master Standard reading before testing each new sample set. 2. Measuring Ferromagnetic Responsiveness of Test Specimens: a. Place the test speci
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBV13212000DETERMINATIONOFFERROMAGNETICRESPONSIVENESSOFADHESIVESSEALERSPDF

链接地址:http://www.mydoc123.com/p-747650.html