1、 FORD LABORATORY TEST METHOD BV 127-01 Date Action Revisions 2000 12 11 Revised Editorial no technical change A. Cockman 1990 09 26 Printed copies are uncontrolled Page 1 of 3 Copyright 2000, Ford Global Technologies, Inc. SEALABILITY OF PRE-APPLIED ANTI-LEAK SEALANTS Application This method defines
2、 tests used to evaluate pre-applied thread sealants for leakage. Apparatus Required 17 N-m Torque Wrench Suitable Stationary Vise Air Circulating Oven with Timer 0 - 207 kPa Single Stage Regulator Gauge. 120 - 200 cu. ft. Cylinder of Dry Nitrogen with Regulator and Valving 75 mm Aluminum Weigh Pan A
3、pplicator Brush Ultra Sonic Degreaser Gloves Water Bath Set at 23 +/- 2 C Test Specimen 13 mm malleable iron pipe tees. 13 mm steel pipe plugs. Conditioning and Test Conditions All test values indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 %
4、relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. FORD LABORATORY TEST METHOD BV 127-01 Page 2 of 3 Copyright 2000, Ford Global Technologies, Inc. Procedure A. Test Specimen Preparation 1. Before applying sealant to the threads
5、 of the plugs, both plugs and tees must be cleaned using appropriate solvent and allowed to cool to 23 +/- 2 C. Store them in an atmosphere of low humidity desiccator for 30 minutes. 2. Remove pipe plugs and tees from the desiccator and arrange them for the assembly of 3 tees per batch of sealant te
6、sted. Hand tighten the plugs into the tees to run out any burrs. This will also threadmate the plugs to its corresponding tee joint. 3. With a waterproof marker, label each tee by the identification number of the product undergoing this test. Similarly, mark each plug and its corresponding tee joint
7、. For example, the plugs of the 1st tee should be marked “A“ and “B“. The plugs corresponding joint on the tee is also marked “A“ and “B“. Repeat this for the next 2 tees of the batch tested as C and D, E and F. 4. Store all the plugged tees in the desiccator. 5. Mark weigh pans with the product I.D
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBV12712000SEALABILITYOFPREAPPLIEDANTILEAKSEALANTSPDF

链接地址:http://www.mydoc123.com/p-747639.html