FORD FLTM BO 116-01-2013 RESISTANCE TO INTERIOR WEATHERING.pdf
《FORD FLTM BO 116-01-2013 RESISTANCE TO INTERIOR WEATHERING.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BO 116-01-2013 RESISTANCE TO INTERIOR WEATHERING.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BO 116-01 Date Action Revisions Rev 02 2013 10 14 Editorial Updated title and added websites L. Soreide, NA 2007 05 08 Revised Revised Apparatus Required, Test Conditions, Calibration, Maintenance, Exposure & Evaluation & Reporting C. Leslie 2005 05 06 Activated C. Lesli
2、e Controlled document at www.MATS Copyright 2013, Ford Global Technologies, LLC Page 1 of 3 RESISTANCE TO INTERIOR WEATHERING Application This procedure is used to determine the effects of simulated weather on interior trim materials using a controlled irradiance water cooled xenon-arc Weather-Omete
3、r with an auxiliary lantern and filters. Apparatus Required Atlas Ci Series Xenon Arc Weather-Ometer Models: Ci 35A, Ci 65A, Ci 4000 or Ci 5000 or equivalent. Auxiliary Lamp Filter Lantern Part Number: 20906800 for models Ci 35A, Ci 65A or equivalent. Part Number: 20909900 for model Ci 4000 or equiv
4、alent. Part Number: 20293100 for model Ci 5000 or equivalent. Available from: Atlas Material Testing Technology LLC 4114 Ravenswood Ave. Chicago, IL 60613 USA http:/atlas- Operating Filter 335 nm long pass filters (SF-5 filters) or equivalent provided the transmission spectrum is within 95% of the S
5、F-5 filter transmission at all wavelengths. The filters are reversible unless otherwise marked by a coating or etching. Dimensions for the Ci 5000 series Weather-Ometer: 339 mm +/- 0.13 mm x 70 mm +/- 0.13 mm x 3 mm +/- 0.52 mm Dimensions for the Ci 35A, Ci 65A & Ci 4000 Weather-Ometer: 220 mm +/- 0
6、.13 mm x 70 mm +/- 0.13 mm x 3 mm +/- 0.52 mm Available from: Atlas Material Testing Technology LLC Schott Glass Technologies, Inc. 4114 Ravenswood Ave. or 400 York Ave. Chicago, IL 60613 USA Duryea, PA 18642 USA http:/atlas- http:/ FORD LABORATORY TEST METHOD BO 116-01 Copyright 2013, Ford Global T
7、echnologies, LLC Page 2 of 3 Lamp Sensor Irradiance Filter 420 nm Irradiance Filter Available from: Atlas Material Testing Technology LLC 4114 Ravenswood Ave. Chicago, IL 60613 USA http:/atlas- Calibration Lamp The calibration lamp must be calibrated to 420 nm with the lantern assembly removed. Avai
8、lable from: Atlas Material Testing Technology LLC 4114 Ravenswood Ave. Chicago, IL 60613 USA http:/atlas- Sample & Test Conditions Sample Conditioning All test values indicated herein are based on material conditioned in a controlled atmosphere of 21 +/- 2 C and 50 +/- 5% relative humidity for not l
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBO116012013RESISTANCETOINTERIORWEATHERINGPDF

链接地址:http://www.mydoc123.com/p-747356.html