FORD FLTM BJ 001-03-2001 METHOD OF DETERMINING LUBRICATION AND ANTI-WEAR PROPERTIES OF HYDRAULIC FLUIDS《液压液的润滑和抗磨性能的测定方法》.pdf
《FORD FLTM BJ 001-03-2001 METHOD OF DETERMINING LUBRICATION AND ANTI-WEAR PROPERTIES OF HYDRAULIC FLUIDS《液压液的润滑和抗磨性能的测定方法》.pdf》由会员分享,可在线阅读,更多相关《FORD FLTM BJ 001-03-2001 METHOD OF DETERMINING LUBRICATION AND ANTI-WEAR PROPERTIES OF HYDRAULIC FLUIDS《液压液的润滑和抗磨性能的测定方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、 FORD LABORATORY TEST METHOD BJ 001-03 Date Action Revisions 2001 07 23 Revised Editorial no technical change A. Cockman 1992 05 05 Printed copies are uncontrolled Page 1 of 6 Copyright 2001, Ford Global Technologies, Inc. METHOD OF DETERMINING LUBRICATION AND ANTI-WEAR PROPERTIES OF HYDRAULIC FLUID
2、S Application This procedure describes a method of gauging the protection of a petroleum-based hydraulic fluid against corrosion, oxidation and physical wear. For modifications to cover water-oil emulsion and water glycol hydraulic fluids, contact Ford Motor Company, Manufacturing Processes Laborato
3、ry, 24500 Glendale, Redford, MI 48239, Tel. (313) 592-2396. Abstract A test fluid is circulated by a pump of prescribed capacity at a specified pressure, flow and temperature. The magnitude of metallic wear on the interior pre-weighed pump components as determined by weight loss over a given time pe
4、riod is a method of gauging the lubrication and anti-wear properties of the test fluid. Changes in the fluid, as a result of pumping, are a measure of oxidation of the fluid. Changes in pump components, other than by wear, may be a measure of corrosion. Apparatus Required Hydraulic Pump 75 L/minute
5、at 1800 R.P.M. vane type V124-Vickers. Electric Motor 1800 R.P.M., 15 H.P. minimum. Reservoir 95 L capacity, stainless steel elevated above pump. Pressure Relief Valve Adjustable - 0 - 13.8 MPa Flow Meter Heat Exchanger Temperature Sensing and Regulating Device FORD LABORATORY TEST METHOD BJ 001-03
6、Page 2 of 6 Copyright 2001, Ford Global Technologies, Inc. Replaceable Type Filer, Gages and Associated Pipe To assemble a closed loop hydraulic circuit. (See test stand diagram - Figure 1) Analytical Balance Precision of +/- 0.1 mg Materials Required Trichloroethane M5B58A Caution: TLV = 350 ppm -
7、Refer to Industrial Hygiene Bulletin No. 14. Acetone Caution: Low flash point. Refer to Fire Control Bulletin No. 18. Methanol Absolute. Caution: Low flash point. Refer to Fire Control Bulletin No. 18. Test Condition Duration 1000 h continuous or until apparent excessive wear as determined by high n
8、oise level, excessive drive motor current, or low flow dictates termination of test. Pressure 6.9 MPa. Pump R.P.M. 1800 R.P.M, shaft speed, basic less slippage of electric drive motor. Reservoir Capacity 95 L capacity. Fill to be limited to one time pump volume on a per minute basis, i.e. 75 L/min =
9、 75 L reservoir fill. Temperature 66 +/- 1 C initial reservoir. The reservoir oil temperature may increase to 74 C as the 1000 h test termination period approaches. (If the test fluid oxidizes, heat exchange heat transfer may be reduced by oxide deposits.) Conditioning and Test Conditions All test v
10、alues indicated herein are based on material conditioned in a controlled atmosphere of 23 +/- 2 C and 50 +/- 5 % relative humidity for not less than 24 h prior to testing and tested under the same conditions unless otherwise specified. FORD LABORATORY TEST METHOD BJ 001-03 Page 3 of 6 Copyright 2001
11、, Ford Global Technologies, Inc. Preparation of Hydraulic Test Pump Interior Components (Ring and Vanes) Since the test conclusions are based on the weight loss of the test pump ring and vanes after 1000 h operation, it is essential that they are prepared in a prescribed manner for determining their
12、 original weight. 1. Remove burrs or other machined irregularities from ring vanes and bushings with an Arkansas hand stone or equivalent. 2. Verify the hardness of the rings and vanes to be HRC 60-63 (harder or softer materials could provide misleading wear data). 3. Submerge ring vanes and bushing
13、s in trichloroethane and clean components thoroughly with a medium bristle brush to remove all foreign matter. 4. Submerge components individually in a trichloroethane rinse bath, followed by an acetone rinse and finally a methanol rinse. 5. Allow components to completely air dry before determining
14、weight. 6. Weigh ring and vanes set independently on an analytical balance to the nearest 0.0001 g. Note: Bushing weights are not included as part of this test. Preparation of Hydraulic Fluid Test Stand Prior to Scheduled Test 1. Prepare pump for flushing by first immersing a cleaned pump cartridge
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDFLTMBJ001032001METHODOFDETERMININGLUBRICATIONANDANTIWEARPROPERTIESOFHYDRAULICFLUIDS 液压 润滑 抗磨性 测定

链接地址:http://www.mydoc123.com/p-747071.html