FORD E-EX002-1996 PORTABLE EQUIPMENT AND ACCESSORIES《便携式设备和配件》.pdf
《FORD E-EX002-1996 PORTABLE EQUIPMENT AND ACCESSORIES《便携式设备和配件》.pdf》由会员分享,可在线阅读,更多相关《FORD E-EX002-1996 PORTABLE EQUIPMENT AND ACCESSORIES《便携式设备和配件》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、4#ia!B Manufacturing Standards E PORTABLE EQUIPWENT AND ACCESSORIES SECTION 1. SCOPE 1.1 GENERAL This standard covers the basic requirements for all portable equipment and accessories and is intended to meet safety requirements, extend the working life of the equipment and to promote uniformity thro
2、ughout the Company (Ford of Britain). It shall be deemed to cover, whether- specifically mentioned or not, such apparatus and parts as may be necessary for the safe and satisfactory operation of any Portable Equipment and Accessories used on any of the Companys premises. 1.2 TYPICAL EQUIPMENT COVERE
3、D BY THIS STANDARD :- * Hand Lamps * Welding Sets * Hand Tools * pumps l Transformers * Compressors l Bench tools * Floor Cleaning machines * Heaters * Plugs h Sockets * Fans (man cooling) * Miscellaneous equipment 1.3 APPLICATION Equipment components and accessories described in this Standard are i
4、ntended for use in all Industrial locations but excluding areas designated as hazardous ie. where flammable substances and explosive vapours or dusts are present except where specifically stated. 1.4 HHLATED STANDARD S AND SPECIFICATIONS All equipment supplied for use on Company premises shall compl
5、y with :- The Provision and Use of Work Equipment Regulations 1992 and all subsequent amendments and additions, Note : Manufacturing ELECTRICAL EQUIPMENT PORTABLE E-EXO02 Administration DESIGN AND REiEEZENCE DATA AUGUST 1996 PAGE 1 OF 11 Manufacturing Standards ai!b 1.4 Continued Equipment shall als
6、o comply with all relevant British Standards covering specific aspects of equipment design, construction and testing. SECTION 2. FLEXIBLE CABLES 2.1 GENERAL 2.1.1 All cables shall be rated to 300/500 volts, and be of heavy duty type, incorporating the following features :- * fine conductor wires for
7、 high flexibility * Colour-coded conductors in accordance with Ford Standard U-BXOOl * Cable sheathing to suit the working environment ie. :- i) pry areas - PVC! ii) wet/oily areas - PUR or NEOPRENE Any special environmental concerns shall be discussed with the Ford Specifying Engineer. 2.1.2 The mi
8、nimum cable size and maximum allowable lengths fitted to the equipment shall be as shown in Appendix No-l. 2.1.3 All cables shall be of a rating suitable for the full load current of the equipment connected, with due allowance being given to voltage drop and short circuit protective devices of the s
9、ervice socket outlet provided for use. 2.2 CABLE INSTALLATION 2.2.1 All flexible cables shall be protected by a suitable reinforced flexible sleeve at the point of entry to the equipment connector. An efficient purpose made cable grip shall be fitted to prevent strain on the individual conductors. 2
10、.2.2 Bxtension leads for extending the cables fixed to equipment shall not be used on voltages exceeding + 55 volts to earth potential. (110 volts centre- tapped transformer) 2.2.3 Rxtension leads shall not in any circumstances be fitted with 2 male connectors. E-EXOO2 ELECTRICAL EQUIPMENT PORTABLE
11、Manufacturing PAGE 2 OF 11 Administration DESIGN AND REFERENCE DATA AUGUST 1996 aiIiiiD Manufacturing Standards E SECTION 3. PLUG AND SOCKET CONNECTIONS 3.1 GENERAL 3.1-l All plugs, sockets, connectors, adapters and equipment terminations shall be properly designed and constructed for the purpose. T
12、hey shall have efficient means of maintaining satisfactory EARTH continuity throughout the system. 3.1.2 Plug and socket connections shall be non-reversible, the RAR!CH contact shall make before and break after the LIVE contacts. 3.1.3 All cable terminals which utilise lock-washers shall be designed
13、 so as to retain the washer with the screw. 3.2 INSTAIAATION 3.2.1 Plugs and sockets shall be designed and selected to serve a particular service, !Fhey shall not be interchangeable between different voltages or frequencies. 3.2.2 Where plugs and sockets are captured by locking rings, or clips, whic
14、h may impede withdrawal and cause delay in an emergency, a switch isolator shall be installed immediately adjacent to the socket to enable it to be isolated from the SuPPlY- 3.2.3 Sockets and switches designed to serve flameproof handlamps etc., shall be installed OUTSIDp the danger area, unless the
15、 outlet and the switch are of flameproof construction. 3.2.4 For socket outlets operating at a voltage in excess of, but not including 250 volts AC., the outlet shall be a combined switch-socket designed to mechanically interlock the plug with the switch. 3.2.5 Sockets serving high-cycle tools may h
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDEEX0021996PORTABLEEQUIPMENTANDACCESSORIES 便携式 设备 配件 PDF

链接地址:http://www.mydoc123.com/p-744793.html