FORD CGX1-1993 TROLLEY CONVEYOR STOCK GUARDS《吊运式输送机牧畜栏》.pdf
《FORD CGX1-1993 TROLLEY CONVEYOR STOCK GUARDS《吊运式输送机牧畜栏》.pdf》由会员分享,可在线阅读,更多相关《FORD CGX1-1993 TROLLEY CONVEYOR STOCK GUARDS《吊运式输送机牧畜栏》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 Manufacturing StandardsFord Motor Company199312 TROLLEY CONVEYOR STOCK GUARDS CGX1Engineering Standards & Printed copies are uncontrolled.Systems Engineering (ESSE) Page 1 of 51. SCOPE: This standard covers trolley conveyor stock guards.2. REFERENCES:American National Standards Institute (ANSI)ASME
2、 B20.1 - Safety Standard for Conveyors and Related EquipmentAmerican Institute of Steel Construction (AISC)American Welding Society (AWS)Conveyor Equipment Manufacturers Association (CEMA)601 - Overhead Trolley Chain ConveyorsOccupational Safety and Health Administration Standards (OSHA) - Title29,
3、Code of Federal Regulations3. GENERAL: Conveyor system design must comply with the latest editionof the referenced standards. In those instances where Ford standardsexceed the referenced standards, Ford standards will apply. It is theresponsibility of the supplier to determine that all standards are
4、 met orrequest a waiver of requirements if necessary. Any waiver must beapproved by the requisitioning activity.4. LOCATION:Guards are required when the lowest point of any part on an overheadconveyor exceeds 7 feet (2.1 m) from the floor.Unless otherwise specified, guards shall have a minimum headr
5、oomclearance of 10 feet (3m) from the floor over aisles and 6 foot 8 inches(2m) for areas other than aisles.5. GENERAL CONSTRUCTION:5.1 Conveyor guard design requires approval of the requisitioningactivitys Safety Engineer prior to fabrication.5.2 Guards must have a minimum clearance of 6 inch (152
6、mm) betweenoutside stock edges and sides and bottom of the guard.5.3 Guards sides must be sufficiently high to retain falling stockwithin the guard as specified by the requisitioning activity. Atminimum, half of the vertical height of the part being conveyedmust be enclosed by the guard.5.4 Guards s
7、hall be constructed to support the maximum stock load beingconveyed should it fall into the guard.Manufacturing StandardsFord Motor Company199312 TROLLEY CONVEYOR STOCK GUARDS CGX1Engineering Standards & Printed copies are uncontrolled.Systems Engineering (ESSE) Page 2 of 55.5 Fastening methods must
8、 not impair the ability of the guard tosupport stock falling into the guard. Sides must be helixed tobottoms (welded when expanded steel mesh is used). Individual “U“shaped sections must be helixed to each other.5.6 Stock retainers shall be installed at 4 foot (1.2 m) intervals toretain stock droppi
9、ng from the conveyor on the inclines anddeclines for the full width of the guards. Retainers must be ofsufficient height to prevent stock from rolling down the incline ordecline.5.7 Hangers shall be a minimum of 1-1/2 X 1-1/2 X 3/16 inch(38.1 X 38.1 X 5 mm) and must have sufficient strength to suppo
10、rtthe guard and guard load in a rigid manner. The maximum spacebetween any two hangers must not exceed 8 feet (2.4 m).5.8 Hangers shall be fastened to header and bottom tie angles with1/2 inch (12.7 mm) diameter grade 5 bolts, two at the top and one atthe bottom per hanger, minimum.5.9 The conveyor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDCGX11993TROLLEYCONVEYORSTOCKGUARDS 吊运式 输送 牧畜 PDF

链接地址:http://www.mydoc123.com/p-744768.html