EN ISO 11073-30200-2005 en Health informatics - Point-of-care medical device communication - Part 30200 Transport profile - Cable connected (Incorporates Amendment A1 2015)《健康信息学 床.pdf
《EN ISO 11073-30200-2005 en Health informatics - Point-of-care medical device communication - Part 30200 Transport profile - Cable connected (Incorporates Amendment A1 2015)《健康信息学 床.pdf》由会员分享,可在线阅读,更多相关《EN ISO 11073-30200-2005 en Health informatics - Point-of-care medical device communication - Part 30200 Transport profile - Cable connected (Incorporates Amendment A1 2015)《健康信息学 床.pdf(110页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN ISO11073-30200:2005Healthinformatics Point-of-caremedicaldevicecommunicationPart 30200:Transport profile CableconnectedThe European Standard EN ISO 11073-30200:2005has the status of aBritish StandardICS 35.240.80 BS EN ISO 11073-30200: 2005+A1:2015BS EN ISO 11073-30200:2005+A1:
2、2015ISBN 978 0 580 86143 7Amendments/corrigenda issued since publicationDate Comments31 December 2015 Implementation of ISO/IEEE amendment 1:2015This British Standard was published under the authority of the Standards Policy and Strategy Committee on 28 April 2006 The British Standards Institution 2
3、015. Published by BSI Standards Limited 2015National forewordThis British Standard is the UK implementation of EN ISO 11073-30200:2005+A1:2015. It supersedes BS EN ISO 11073-30200:2005, which is withdrawn. It is identical to ISO/IEEE 11073-30200:2004, incorporating amendment 1:2015.The start and fin
4、ish of text introduced or altered by amendment is indicated in the text by tags. Tags indicating changes to ISO text carry the number of the ISO amendment. For example, text altered by ISO amendment 1 is indicated by .The UK participation in its preparation was entrusted to Technical Committee IST/3
5、5, Health informatics.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot
6、 confer immunity from legal obligations.EUROPEANSTANDARDNORMEEUROPENNEEUROPISCHENORMEN ISO 11073-30200August 2005ICS 35.240.80EnglishVersionHealthinformatics -Point-of-care medical devicecommunication-Part 30200:Transport profile-Cableconnected(ISO/IEEE11073-30200:2004)Informatiquede sant-Communicat
7、ion entredispositifsmdicaux sur le sitedes soins-Partie 30200:Profildetransport -Connexion par cble (ISO/IEEE 11073-30200:2004)MedizinischeInformatik -Kommunikation patientennahermedizinischer Gerte-Teil 30200:Transportprofil-drahtgebundenebertragungThis European Standard was approvedby CEN on 16 Au
8、gust 2005.CENmembers areboundtocomply with theCEN/CENELECInternalRegulations which stipulate theconditionsforgivingthisEuropeanStandard the status ofanational standardwithout any alteration. Up-to-date listsandbibliographical referencesconcerningsuchnationalstandards may be obtained on application t
9、o theCentral Secretariat or to any CEN member.ThisEuropean Standardexistsin threeofficial versions (English,French,German).A versionin any other language madeby translationunder the responsibility ofaCEN member into its own languageand notified to theCentralSecretariat has thesame status as the offi
10、cialversions.CEN members are the national standards bodies ofAustria,Belgium,Cyprus,CzechRepublic,Denmark,Estonia,Finland,France,Germany,Greece,Hungary,Iceland,Ireland,Italy,Latvia,Lithuania,Luxembourg,Malta,Netherlands,Norway,Poland,Portugal,Slovakia,Slovenia,Spain,Sweden,SwitzerlandandUnitedKingdo
11、m.(8523($1 also called a frame check sequence. The CRC is appended to the transmitted frame. At the receiver, the calculation creating the CRC may be repeated, and the result compared to that encoded in the signal. Syn: frame check sequence.device communications controller (DCC): A communications in
12、terface associated with a medical device. A DCC may support one or more physically distinct devices acting as a single network communications unit. Its purpose is to provide a point-to-point serial communication link to a BCC.electromagnetic compatibility (EMC): The ability of a device, equipment, o
13、r system to function satisfactorily in its electromagnetic environment without introducing intolerable electromagnetic disturbances to anything in that environment.electromagnetic interference (EMI): Signals emanating from external sources (e.g., power supplies, transmitters) or internal sources (e.
14、g., adjacent electronic components, energy sources) that disrupt or prevent operation of electronic systems.2The IEEE Standards Dictionary: Glossary of Terms , HFKDQJHVWDWLRQLGHQWLILFDWLRQ;0,7 WUDQVPLWWLQJ91 YHUVLRQQXPEHU4. Goals for this standard7KHIROORZLQJDUHWKHPDLQJRDOVIRUWKLVVWDQGDUGD 7KH VWDQG
15、DUG VKDOO DOORZ WKH XVH RIHLVWLQJ 56 SRUW GHVLJQVWRPLQLPLH GHVLJQ ULVNFRQWDLQSURGXFWFRVWVDQGVLPSOLIILHOGXSJUDGHVE 7KHVWDQGDUGVKDOOVSHFLIKDUGZDUHDQGVRIWZDUHHOHPHQWVWKDWDUHDYDLODEOHIURPPXOWLSOHYHQGRUVF 7KH VWDQGDUG VKRXOG PDNH XVH RI RWKHU FRPSXWHU LQGXVWU FRPPXQLFDWLRQ WHFKQRORJ WR DOORZ IRUFRQWLQXRX
16、VFRVWGHFUHDVHVG 7KHVWDQGDUGVKRXOGPHHWWKHUHTXLUHPHQWVRI,(6WGH 7KHVWDQGDUGVKRXOGEHFRPSDWLEOHZLWKWKHFXUUHQWSXEOLVKHGDQGGUDIW,($16,VWDQGDUGXSSHUODHUV5. Architecture7KLVFODXVHLVLQWHQGHGWRGHILQH,62,(QHWZRUNWRSRORJDQGSURWRFROODHULQJ5.1 Topology7KH ,62,(QHWZRUNGHILQHVDVWDUWRSRORJUHTXLULQJHDFKGHYLFHWRKDYHLWV
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ENISO11073302002005ENHEALTHINFORMATICSPOINTOFCAREMEDICALDEVICECOMMUNICATIONPART30200TRANSPORTPROFILECABLECONNECTEDINCORPORATESAMENDMENTA12015

链接地址:http://www.mydoc123.com/p-724307.html