1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationAutomatic test systems for battery powered emergency escape lightingBS EN 62034:2012National forewordThis British Standard is the UK implementation of EN 62034:2012. It is identi
2、cal to IEC 62034:2012. It supersedes BS EN 62034:2006, which will bewithdrawn on 28 March 2015.The UK participation in its preparation was entrusted by Technical CommitteeCPL/34, Lamps and Related Equipment, to Subcommittee CPL/34/4,Luminaires.A list of organizations represented on this committee ca
3、n be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. The British Standards Institution 2012Published by BSI Standards Limited 2012ISBN 978 0 580 67363 4ICS 29.140.50Complian
4、ce with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on 30 June 2012.Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 62034:2012EUROPEAN STANDAR
5、D EN 62034 NORME EUROPENNE EUROPISCHE NORM May 2012 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2012 CENELEC - All rights of exp
6、loitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 62034:2012 E ICS 29.140.50 Supersedes EN 62034:2006English version Automatic test systems for battery powered emergency escape lighting (IEC 62034:2012) Systmes automatiques dessai pour clairage de scurit sur
7、batteries (CEI 62034:2012) Automatische Prfsysteme fr batteriebetriebene Sicherheitsbeleuchtung fr Rettungswege (IEC 62034:2012) This European Standard was approved by CENELEC on 2012-03-28. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions
8、for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists i
9、n three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national
10、 electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain,
11、Sweden, Switzerland, Turkey and the United Kingdom. BS EN 62034:2012EN 62034:2012 - 2 - Foreword The text of document 34D/1040/FDIS, future edition 2 of IEC 62034, prepared by SC 34D, “Luminaires“, of IEC TC 34, “Lamps and related equipment“ was submitted to the IEC-CENELEC parallel vote and approve
12、d by CENELEC as EN 62034:2012. The following dates are fixed: latest date by which the document has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2012-12-28 latest date by which the national standards conflicting with the document have t
13、o be withdrawn (dow) 2015-03-28 This document supersedes EN 62034:2006. The main changes with respect to EN 62034:2006 are the improvement of the understanding of the requirements in the various clauses and the compliance requirements listed below and the updating of the normative references. 4.2 Mo
14、nitoring of the timing circuit 4.3 Functional requirements 4.3.1 The automatic test system (ATS) 4.4.2 Intercommunications failure 4.4.4 Component failures 4.4.7 Software failure 5.1 Functional test 5.2 Duration test 6.2.2 Timing accuracy 6.3.2.2 Testing alternate luminaires 6.3.3.4 Limited duration
15、 test 7.1 General Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. BS EN 62034:2012- 3 - EN 62034:2012 Endorsement notice The text of t
16、he International Standard IEC 62034:2012 was approved by CENELEC as a European Standard without any modification. In the official version, for Bibliography, the following notes have to be added for the standards indicated: IEC 61347-2-7 NOTE Harmonized as EN 61347-2-7. IEC 61347-2-11 NOTE Harmonized
17、 as EN 61347-2-11. BS EN 62034:2012EN 62034:2012 - 4 - Annex ZA (normative) Normative references to international publications with their corresponding European publications The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its applic
18、ation. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an international publication has been modified by common modifications, indicated by (mod), the relevant EN/HD applies. Pub
19、lication Year Title EN/HD Year IEC 60073 - Basic and safety principles for man-machine interface, marking and identification - Coding principles for indicators and actuators EN 60073 - IEC 60598-1 - Luminaires - Part 1: General requirements and tests EN 60598-1 - IEC 60598-2-22 - Luminaires - Part 2
20、-22: Particular requirements - Luminaires for emergency lighting EN 60598-2-22 - IEC 61347-1 - Lamp controlgear - Part 1: General and safety requirements EN 61347-1 - IEC 61547 - Equipment for general lighting purposes - EMC immunity requirements EN 61547 - BS EN 62034:2012 2 62034 IEC:2012 CONTENTS
21、 INTRODUCTION . 6 1 Scope 7 2 Normative references . 7 3 Terms and definitions . 7 4 Requirements . 9 4.1 Safety, construction and installation instructions . 9 4.2 Monitoring of the timing circuit . 9 4.3 Functional requirements 9 4.3.1 The automatic test system (ATS) 9 4.3.2 Emergency battery supp
22、ly 10 4.3.3 Lamps tested in the emergency mode . 10 4.3.4 Maintained luminaires tested in emergency mode and in normal mains condition 10 4.4 System integrity . 10 4.4.1 Protection against system part failures and faults . 10 4.4.2 Intercommunications failure 11 4.4.3 System interconnection 11 4.4.4
23、 Component failures 11 4.4.5 System parts compatibility 11 4.4.6 Electromagnetic immunity of the ATS . 12 4.4.7 Software failure 12 4.5 Test of emergency lamp(s) . 12 5 Test duration and interval . 13 5.1 Functional test . 13 5.2 Duration test 13 6 Protection of a building during the periods of test
24、 and subsequent recharge of the emergency lighting system 14 6.1 General . 14 6.2 Accuracy and protection of timing periods 14 6.2.1 General . 14 6.2.2 Timing accuracy . 14 6.2.3 Protection of timing function . 14 6.3 Requirements for premises that may be occupied during test and recharge periods 15
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN620342012ENAUTOMATICTESTSYSTEMSFORBATTERYPOWEREDEMERGENCYESCAPELIGHTINGPDF

链接地址:http://www.mydoc123.com/p-720864.html