EN 50411-3-1-2012 en Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 3-1 Fibre management system splice wall box for.pdf
《EN 50411-3-1-2012 en Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 3-1 Fibre management system splice wall box for.pdf》由会员分享,可在线阅读,更多相关《EN 50411-3-1-2012 en Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 3-1 Fibre management system splice wall box for.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 50411-3-1:2012Fibre organisers and closures to be used in optical fibre communication systems Product specificationsPart 3-1: Fibre management system, splice wall box, for
2、category C for external above ground; IEC 61753-1:2007, category C IEC 61753-1:2007, category G Fibre separation level - FMS splice trays: Single circuit (2 fibres per tray), Single ribbon (4 fibres per tray), Single element (12 fibres per tray), Multiple ribbon (144 fibres per tray) Multiple elemen
3、t (144 fibres per tray) For reference on how fibre separation levels fits into the modularity of FMS organisers, see also FMS organiser options in Annexes C to E Construction and splice tray capacity: FMS Number splice trays (maximum) for each fibre separation level SC, SE, SR, ME and MR Number of t
4、rays needed for: S organiser M organiser Single circuit SC (4f) Single element SE (12f) Single ribbon SR (4f) Multiple element ME (144f) Multiple ribbon MR (144) Typical capacity 12 fibres 6 1 3 1 1 Typical capacity 144 fibres 36 12 36 1 1(12 f/R) Box type - minimum no of cable entries: Track box -
5、2 Spur box - 3 Distribution box - 6 Schematic diagrams (Cable entries can be in any orientation) Typical installations A Street cabinet or external configurations Typical installations B Office internal configurations BS EN 50411-3-1:2012EN 50411-3-1:2012 - 6 - 1 Scope 1.1 Product definition This Eu
6、ropean Standard covers wall boxes for up to 288 fibre splices. Wall boxes for connectors will be covered in a future part of the EN 50411-3 series. This European Standard covers two environmental service requirements, for use inside a building under category C and externally of buildings under categ
7、ory G both to EN 61753-1:2007. This European Standard contains the initial, start of life dimensional, optical, mechanical and environmental performance requirements of a fully installed optical fibre wall box, in order for it to be categorised as an EN standard product. The wall box must be suitabl
8、e for fixing to a vertical internal or external surface above ground level. The wall box is a housing containing a fibre management system, containing splice trays of various fibre separation levels, and may contain one or more of the following: storage and/or routing of cable; through-box/uncut fib
9、re, cable storage; passive devices. This document specifies the number of splice trays for each fibre separation level. 1.2 Operating environment The tests selected combined with the severity and duration is representative of indoor and outside plant for above ground environments defined by: EN 6175
10、3-1: - category C: Controlled environment - category G: Ground level environment 1.3 Reliability Whilst the anticipated service life expectancy of the product in this environment is 20 years, compliance with this European Standard does not guarantee the reliability of the product. This should be pre
11、dicted using a recognised reliability assessment programme. 1.4 Quality assurance Compliance with this European Standard does not guarantee the manufacturing consistency of the product. This should be maintained using a recognised quality assurance programme. 1.5 Allowed fibre and cable types All ty
12、pes of fibre are permitted for a FMS with a minimum bend radius of 30 mm. A minimum bend of 20 mm can only be used with a B 6 fibre. The box, once tested according to this product specification, will be also suited for other fibre types, for example bend insensitive, dispersion shifted, non-zero dis
13、persion shifted and multimode fibres. This wall box standard allows both single-mode and multi-mode fibre to be used and covers all IEC standard optical fibre cables with their various fibre capacities, types and designs as long as fitting in the box does not contravene the minimum bend radius. The
14、minimum bend radius of fibre depends on its type, and is applicable for all operational wavelengths: EN 60793-2-10, Type A1 multimode fibre is 30 mm; EN 60793-2-50, Type B 1.1 and B 1.3 singlemode fibre is 30 mm; (20 mm is accepted for total lengths less than 2 m) EN 60793-2-50, Type B6-a1, B6-a2 si
15、nglemode fibre (ITU-T G.657) is 20 mm (15 mm is accepted for total lengths less than 0,5 m) BS EN 50411-3-1:2012EN 50411-3-1:2012 - 7 - 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For date
16、d references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 50411-2 Fibre organisers and closures to be used in optical fibre communication systems Product specifications Part 2: General and guidance for o
17、ptical fibre cable joint closures, protected microduct closures, and microduct connectors EN 60529 Degrees of protection provided by enclosures (IP Code)(IEC 60529) EN 60695-11-10 Fire hazard testing Part 11-10: Test flames 50 W horizontal and vertical flame test methods (IEC 60695-11-10) EN 60793-2
18、-50:2008 Optical fibres Part 2-50: Product specifications Sectional specification for class B single-mode fibres (IEC 60793-2-50:2008) EN 60793-2-10 Optical fibres Part 2-10: Product specifications Sectional specification for category A1 multimode fibres (IEC 60793-2-10) EN 60794-2 Optical fibre cab
19、les Part 2: Indoor cables Sectional specification (IEC 60794-2) EN 60794-3 Optical fibre cables Part 3: Sectional specification Outdoor cables (IEC 60794-3) EN 61034-1 Measurement of smoke density of cables burning under defined conditions Part 1: Test apparatus (IEC 61034-1) EN 61300-2-1 Fibre opti
20、c interconnecting devices and passive components Basic test and measurement procedures Part 2-1: Tests Vibration (sinusoidal) (IEC 61300-2-1) EN 61300-2-4 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-4: Tests Fibre/cable retention (IEC 61300
21、-2-4) EN 61300-2-9 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-9: Tests Shock (IEC 61300-2-9) EN 61300-2-12:2009 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-12: Tests Impact (IEC 6
22、1300-2-12:2009) EN 61300-2-22 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-22: Tests Change of temperature (IEC 61300-2-22) EN 61300-2-26 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2
23、-26: Tests Salt mist (IEC 61300-2-26) EN 61300-2-33 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 2-33: Tests Assembly and disassembly of fibre optic closures (IEC 61300-2-33) EN 61300-2-34 Fibre optic interconnecting devices and passive compon
24、ents Basic test and measurement procedures Part 2-34: Tests Resistance to solvents and contaminating fluids of interconnecting components and closures (IEC 61300-2-34) EN 61300-3-1 Fibre optic interconnecting devices and passive components Basic test and measurement procedures Part 3-1: Examinations
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN50411312012ENFIBREORGANISERSANDCLOSURESTOBEUSEDINOPTICALFIBRECOMMUNICATIONSYSTEMSPRODUCTSPECIFICATIONSPART31FIBREMANAGEMENTSYSTEMSPLICEWALLBOXFORPDF

链接地址:http://www.mydoc123.com/p-717127.html