EN 50411-2-4-2012 en Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 2-4 Sealed dome fibre splice closures Type 1 fo.pdf
《EN 50411-2-4-2012 en Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 2-4 Sealed dome fibre splice closures Type 1 fo.pdf》由会员分享,可在线阅读,更多相关《EN 50411-2-4-2012 en Fibre organisers and closures to be used in optical fibre communication systems - Product specifications - Part 2-4 Sealed dome fibre splice closures Type 1 fo.pdf(40页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 50411-2-4:2012Fibre organisers and closures to be used in optical fibre communication systems Product specificationsPart 2-4: Sealed dome fibre splice closures Type 1, for
2、category S no other technical changes were made to the document. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. 4 Fibre organisers an
3、d closures to be used in optical fibre communication systems Product specifications Part 2-4: Sealed dome fibre splice closures Type 1, for category S for aerial; EN 61753-1 category S EN 61753-1 category A Related documents: EN 60793-2-50 Optical fibres Part 2-50: Product specifications Sectional s
4、pecification for class B single-mode fibres (IEC 60793-2-50) EN 60794-2 Optical fibre cables Part 2: Indoor cables Sectional specification (IEC 60794-2) EN 60794-3 Optical fibre cables Part 3: Sectional specification Outdoor cables (IEC 60794-3) EN 61753-1 1)Fibre optic nterconecting devices and pas
5、ive componets perfomance standard Part 1:General and guidance for performance standard (IEC 61753-1) EN 61300 series Fibre optic interconnecting devices and passive components Basic test and measurement procedures (IEC 61300 series) ETS 300 019 Environmental Engineering (EE) - Environmental conditio
6、ns and environmental tests for telecommunications equipment Construction and splice capacity: Variant: Number fibre splices - Maximum capacity b) manufacturing date code: year / month. The preferred colour for the outer closure material is black for polymeric materials. 4 Variants Table 1 Sealed dom
7、e fibre splice closure Type 1, for category S - Variants EN 50411-2-4 X1 XX2 X3 XX4 XX5 X6Variant No. X1Operating environment S Subterranean environment A Aerial environment B Both subterranean and aerial environments Variant No. XX2Closure application base number of cables T1 Track closure (2 cable
8、s minimum) S1 Spur closure (3 cables minimum) D1 Distribution (8 cables minimum) D2 Distribution (18 cables minimum) D3 Distribution (34 cables minimum) D4 Distribution (66 cables minimum) Variant No. X3Cable sealing technology heat, non-heat or both R Cold applied H Heat activated (heat source requ
9、ired) U Universal, both methods in a single cable entry base BS EN 50411-2-4:2012 EN 50411-2-4:2012 (E) 10 Variant No. XX4Type of organiser system SC Single Circuit (1 or 2 fibres) S organisers NOTE in some cases an M organiser tray can be used as SC or SE organiser tray (by reducing number of store
10、d splices per tray) SE Single Element (4 or more fibres) SR Single Ribbon (4 or more fibres per ribbon) ME Multiple Element (two or more units) M organisers MR Multiple Ribbon (six or more ribbons 4 fibres per ribbons) Depending on the selection of XX4, refer to one of the following Tables 1a, 1b, 1
11、c, 1d and 1e to find XX5and X6: Table 1a SC tray and closure selection XX5 SC trays 06 12 18 24 30 36 42 48 54 60 66 72 96 120 Maximum splice capacity (reference) 12 24 36 48 60 72 84 96 108 120 132 144 192 240 X6Closure B C D E F G NOTE A SC tray contains 2 fibre splices per tray. BS EN 50411-2-4:2
12、012 EN 50411-2-4:2012 (E) 11 Table 1b SE tray and closure selection XX5SE tray 01 02 03 04 05 06 07 08 12 16 18 24 36 42 48 52 60 72 Maximum splice capacity (reference) 12 24 36 48 60 72 84 96 144 192 216 288 432 504 576 624 720 864 X6Closure B CDE FGH NOTE A SE tray contains 12 fibre splices per tr
13、ay. BS EN 50411-2-4:2012 EN 50411-2-4:2012 (E) 12 Table 1c SR tray and closure selection XX5SR tray 2 4 5 6 7 8 9 10 12 16 18 24 36 Maximum splice capacity (reference) 24 48 60 72 84 96 108 120 144 192 216 288 432 X6Closure BCDEFH NOTE 1 A SR tray has 1 ribbon per tray. NOTE 2 A ribbon has 12 fibres
14、. When using ribbons with a different fibre count than 12 fibres per ribbon, the maximum splice capacity should be changed accordingly. Table 1d ME splice tray and closure selection XX5 ME tray 1A 2A 3A 1B 2B 3B 4B 5B 6B 1D 2D 3D 4D 5D 6D 7D 8D Maximum splice capacity (reference) 24 48 72 24 48 72 9
15、6 120 144 72 144 216 288 360 432 504 576 X6Closure A B C D NOTE 1 ME- Size A and ME- Size B trays have a minimum of 24 splices per tray. NOTE 2 ME- Size D trays have a minimum of 144 splices per tray. BS EN 50411-2-4:2012 EN 50411-2-4:2012 (E) 13 Table 1e MR splice tray and closure selection XX5MR t
16、ray 1D 2D 3D 4D 6D 8D 1H 2H 3H 4H 5H 6H 7H 8H Maximum splice capacity (reference) 36 72 108 144 216 288 144 288 432 576 720 864 1 008 1 152 X6Closure GH NOTE 1 MR- Size D trays have a minimum of 24 splices/fibres per tray. NOTE 2 MR- Size H trays have a minimum of 144 splices/fibres per tray. NOTE 3
17、 A ribbon has 12 fibres. When using ribbons with a different fibre count than 12 fibres per ribbon, the maximum splice capacity should be changed accordingly. This product specification concerns organisers of only one “Type of organiser system” at a given fibre separation level in parameter XX4. If
18、multiple “Types of organisers/levels” in a single closure is required when ordering; then, typically double the number of SC trays can be inserted in the same organiser envelope as SE. Therefore Maximum splice capacity 2 * (number of SC trays) + 12 * (number of SE trays) EXAMPLES EN 50411-2-4 S D2 H
19、 SC 06 E Distribution 18 cable minimum closure, for underground application with heat activated cable seals, SC fibre management system with 6 SC trays (12 splices) in a size E closure. EN 50411-2-4 A T1 C MR 4D G A track 2 cable minimum joint closure, for aerial application with cold applied cable
20、seals and MR fibre management with 4 splice trays type MR-D in a size G closure. BS EN 50411-2-4:2012 EN 50411-2-4:2012 (E) 14 5 Dimensional requirements 5.1 Dimensions of closures for Multiple Element and Multiple Ribbon fibres EDaniel DaemsFigure 1 Outline dimensions of M closure Table 2 M Closure
21、 dimensions Closure size Maximum capacity Number of fibres (without storage basket) Outline M closure envelope dimensions (max.) M organiser system Overall length mmE Overall diameter mm F1 Overall diameter mm F2 Multiple Element Multiple Ribbon A 72 fibres NA 505 185 265 B 96 fibres 600 C 144 fibre
22、s 270 312 D 576 fibres 750 G NA 288 fibres 800 275 310 H 1 152 fibres 1 050 NOTE Additional information on the organiser system can be found in Annex D. F1 F2 BS EN 50411-2-4:2012 EN 50411-2-4:2012 (E) 15 5.2 Dimensions of closures for Single Circuit, Single Element and Single Ribbon Single stackF1F
23、2F1F2F1F2Double stackH (D) G (D)F (D) E (D)EEDCEBDaniel DaemsFigure 2 Outline dimensions of the S closures Table 3 S Closure with SC, SE and SR trays Closure size Maximum capacity Number of fibres (without storage basket) Outline S closure envelope dimensions (max.) S organiser system (common) Overa
24、ll length mmE Overall diameter mm F1 Overall diameter mm F2 Single Circuit Single Element Single Ribbon B aSingle stacks 12f 72f 48f 600 185 265 C 24f 144f 72f 270 312 D 48f 288f 144f 750 E Double stacks 84f 216f 144f 540 275 310 F 144f 432f 288f 620 G 192f 624f 384f 800 H N/A 864f 432f 1 050 NOTE A
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN50411242012ENFIBREORGANISERSANDCLOSURESTOBEUSEDINOPTICALFIBRECOMMUNICATIONSYSTEMSPRODUCTSPECIFICATIONSPART24SEALEDDOMEFIBRESPLICECLOSURESTYPE1FOPDF

链接地址:http://www.mydoc123.com/p-717123.html